securely�

5�  Secure the fixture with a safety cable as directed below�

Securing with a safety cable

Secure the fixture with a safety cable (or other secondary attachment) that is approved for the weight of 
the fixture so that the safety cable will hold the fixture if a primary attachment fails�

Loop the safety cable through the eyebolt in the back of the fixture and around a secure anchoring 
point� Do not loop the safety cable around the fixture’s mounting bracket only, as this will leave the 
fixture unsecured if it separates from the bracket�

DMX-512 connection/connection between fixtures

Occupation of the XLR-connection:

1. Group

2. Signal (-)

3. Signal (+)

DMX OUT

1. Group

2. Signal (-)

3. Signal (+)

DMX IN

If you are using controllers with this occupation, you can connect the DMX-output of the controller 
directly with the DMX-input of the first fixture in the DMX-chain� If you wish to connect DMX-controllers 
with other XLR-outputs, you need to use adapter-cables�

Building a serial DMX-chain:

Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture�
Always connect one output with the input of the next fixture until all fixtures are connected�

DMX-512 connection with DMX terminator:

For installations where the DMX cable has to run a long distance or is in an electrically noisy 
environment, such as in a discotheque, it is recommended to use a DMX terminator� This helps in 
preventing corruption of the digital control signal by electrical noise� The DMX terminator is simply an 
XLR plug with a 120 resistor connected between pins 2 and 3, which is then plugged into the output 
XLR socket of the last fixture in the chain�

Caution: 

At the last fixture, the DMX-cable has to be terminated with a terminator� Solder a 120 

resistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the 
last fixture�

Connection with the mains:

The  LEDE 100B is equipped with auto-switching power supply that automatically adjusts to any 50-
60Hz AC power source from 100-240 Volts�

This fixture must be earthed� To use the fixture, a plug must be fixed�
The correct assembly of a sufficient plug may be done by professional persons only�
Connect the device to the mains with the enclosed power supply cable�

The occupation of the connection cables as below:

Cable color

Connection

International

Brown

Live

L

Blue

Neutral

N

Summary of Contents for LEDE 100B

Page 1: ...USER MANUAL LEDE 100B 100 watts Compact LED Beam Moving Head...

Page 2: ...4 Mounting the fixture on a truss 4 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Operation 6 Addressing 6 Universal DMX Control 6 Auto run mode 6 Sound Mode 6 Master...

Page 3: ...n period of at least 10 minutes before handling or transporting the device Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructi...

Page 4: ...d it on a surface or leave it where it can be moved or fall over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed below with a securely an...

Page 5: ...xt fixture Always connect one output with the input of the next fixture until all fixtures are connected DMX 512 connection with DMX terminator For installations where the DMX cable has to run a long...

Page 6: ...ans changing the settings of one channel will affect only the selected fixture In the case of the LEDE 100B which is 16 channels fixture If you set for example the address in the 16 channel mode to ch...

Page 7: ...ed DISP Screen saver Off Display shut off time always on Mod 1 Display blackout Mod 2 Show DMX address and control mode Mod 3 Show brand icons Screen Rot Auto Screen reverse Reverse Forward DMX Indica...

Page 8: ...strobe slow fast 192 255 Random strobe slow fast CH7 Dimmer 000 255 0 100 dimmer CH8 Color wheel 000 005 Open hole Color 006 011 Color 1 012 017 Color 2 018 023 Color 3 024 028 Color 4 029 034 Color...

Page 9: ...0 255 Focus CH16 Reset 000 127 No function 128 255 Reset in 3sec Fixture Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out p...

Page 10: ...ame size and rating only 3 Reinstall the fuseholder cap before reapplying power Troubleshooting Listed below are a few common problems that you may encounter with solutions The fixture does not work n...

Page 11: ...Electronic variable strobe Static gobo 13 gobos open Rotating gobo 7 gobos open Gobo shake function Prism 16 facet circular prism Frost Control protocols DMX Sound Master Slave Auto Run Control channe...