Error Codes
Error codes notify you of a problem condition and are displayed on the center of the console. These
codes can also help to indicate the part of the unit most likely to be causing the problem. Errors that
present a hazard to the user provide a measure of safety by causing a one second beep, stopping the
unit and locking out operation of the unit.
A log of errors can be viewed and cleared. Up to 10 errors can be stored.
To enter
Test Mode:
Press and hold down any key on the display while turning the power switch to
the on (I) position.
To view the Error Log:
Press the
Strides Per Minute
key to display and cycle through error log; Press
again to cycle to the next stored error.
To clear the Error Log:
Press the
Scan
key twice.
To exit
Test Mode:
Press the
Stop
key.
NOTE:
A processor upset can cause a bAd#. See F then G.
Error
Description
bAd0
Bad check sum. See F then E.
bAd2
Internal RAM error. See F then E.
bAd3
Watchdog timeout. See F then E.
Err3
Speed sense lost. See A and B.
Err5
No index switch sense within timed limits. This is declared when the timed elevation
reaches 0% without tripping the index. See D and A.
Err7
EEPROM error (memory lost, loads new defaults, enters
Test Mode
). See E.
ErrE
Index switch always on (or switch disconnected or wired backwards). This means that timed
elevation has gone up 3 positions and the index is still sensed. See D.
Action
A
Check the lower board
B
Check the brake
C
Check the speed sensor and speed sensor disc
D
Check the elevation motor
E
Replace the display board is problem persists
F