Cybex Arc Trainer 610A Service Manual
7.
Secure the side covers.
A.
Place the two side covers and gasket in position.
B.
Using a Phillips head screwdriver, attach each side cover with the six screws and six washers
removed in step 4A.
8.
Attach the connecting rods.
A.
Place each connecting rod in position.
B.
Using a 3/16” Allen wrench, attach each connecting rod with a screw removed in step 3A. See
Figure 4.
9.
Attach the access cover.
A.
While being sure not to pinch any cables, place the access cover in position.
B.
Using a Phillips head screwdriver, attach the four screws removed in step 2A.
Arm and Handle Link
NOTE:
The arms and handle links are removed in the same way. This procedure can be used for
both.
Tools Required
• Phillips head screwdriver
• 3/16” Allen wrench
• 7/32” Allen wrench
1.
Disconnect the external power source.
A.
Turn the main power switch above the power inlet to the off (O) position.
B.
Unplug the power cord from the power outlet.
2.
Disconnect the contact heart rate cable.
A.
Unplug the contact heart rate cable from the main frame. See Figure 23.
3.
Remove the handle link.
A.
Using a Phillips head screwdriver or 3/16” Allen wrench, remove each screw securing the
(appropriate) cap. See Figure 24.
B.
Remove the caps.
C.
Slide the handle link off the foot plate arm shaft.
D.
Slide the handle link off the arm shaft.
NOTE:
Arm will move freely. Hold in place until step 4.
Service
Page 4-28