CPU Temp. Limit of OFF
option can only be set if the
FAN x Mode Setting
option is
set to
Automatic Mode
. Use the
CPU Temp. Limit of OFF
option to select the CPU
temperature at which the cooling fan should automatically turn off. To select a value,
select the
CPU Temp. Limit of OFF
option and enter a decimal number between 000 and
127. The temperature range is specified below.
Minimum Value: 0°C
Maximum Value: 127°C
Î
Temperature Limit of Start [025]
WARNING:
Setting this value too high may cause the fan to start only when the
CPU is at a high temperature and therefore cause the system to be
damaged.
The
Temperature Limit of Start
option can only be set if the
FAN x Mode Setting
option
is set to
Automatic Mode
. Use the
Temperature Limit of Start
option to select the CPU
temperature at which the cooling fan should automatically turn on. When the fan starts, it
rotates using the starting pulse width modulation (PWM) specified in the
Fan Start PWM
option. To select a value, select the
Temperature Limit of Start
option and enter a
decimal number between 000 and 127. The temperature range is specified below.
Minimum Value: 0°C
Maximum Value: 127°C
Î
Temperature Limit of Full [080]
WARNING:
Setting this value too high may cause the system to become too hot
and cause irreparable damage to the system.