CyberResearch CEGC Series User Manual Download Page 217

CyberResearch

® 

CPU Cards 

 

CEGC Series 

 

CyberResearch, Inc

.  

195

 

25 Business Park Drive 

 

P: (203) 643-5000; F: (203) 643-5001 

Branford, CT USA 

 

www.cyberresearch.com 

 

Figure 

Error! No text of specified style in document.

-98: Intel® PRO Network 

Connections window 

Step 18: 

Click 

I

NSTALL 

D

RIVERS

 in 

Figure Error! No text of specified style in 

document.

-98. 

Step 19: 

The 

Intel® PRO Network Connections

 

Welcome

 screen in 

Figure Error! No 

text of specified style in document.

-99 appears. 

 

Summary of Contents for CEGC Series

Page 1: ...is manual may be reproduced without permission CEGC Series PICMG 1 3 Single Board Computer with VGA Audio USB SATA RAID and LAN CyberResearch Inc www cyberresearch com 25 Business Park Dr Branford CT...

Page 2: ......

Page 3: ...yberResearch and CEGC Series are trademarks of CyberResearch Inc Other product names mentioned herein are used for identification purposes only and may be trademarks and or registered trademarks of th...

Page 4: ...CEGC Series CyberResearch CPU Cards iv Copyright 2008 CyberResearch Inc CEGC Series Revision Description Date of Issue 1 0 Initial Release August 2007 2 0C Revision September 16th 2008...

Page 5: ...and bold and is followed by text The text is the warning message A warning message is shown below WARNING This is an example of a warning message Failure to adhere to warning messages may result in pe...

Page 6: ...ial but non critical information These messages should be read carefully as any directions or instructions contained therein can help avoid making mistakes Notes are easy to recognize The word note is...

Page 7: ...contact a CyberResearch sales representative at sales cyberresearch com or visit the CyberResearch website http www cyberresearch com The items listed below should all be included in the CEGC package...

Page 8: ...CEGC Series CyberResearch CPU Cards viii Copyright 2008 CyberResearch Inc...

Page 9: ...eld Processors 12 2 3 3 Supported Intel Core 2 Duo Wolfdale Processors 12 2 3 4 Supported Intel Core 2 Duo Conroe 2M Processors 12 2 3 5 Supported Intel Celeron Conroe L Processors 13 2 4 INTEL Q35 NO...

Page 10: ...ementation 27 2 6 CEGC PCIE BUS COMPONENTS 28 2 6 1 PCIe Bus Overview 28 2 6 2 PCIe x16 Expansion 28 2 6 3 PCIe x1 Expansion 29 2 6 4 Intel 82573L PCIe GbE Controller 29 2 7 PCI BUS COMPONENTS 31 2 7...

Page 11: ...CEGC Layout 48 4 1 2 Peripheral Interface Connectors 48 4 1 3 External Interface Panel Connectors 49 4 2 INTERNAL PERIPHERAL CONNECTORS 50 4 2 1 ATX Power Connector 50 4 2 2 Audio Connector 52 4 2 3...

Page 12: ...ER SETTINGS 90 5 5 1 Clear CMOS Jumper 91 5 6 CHASSIS INSTALLATION 93 5 6 1 Airflow 93 5 6 2 Backplane Installation 93 5 6 3 CPU Card Installation 94 5 7 INTERNAL PERIPHERAL DEVICE CONNECTIONS 94 5 7...

Page 13: ...3 5 2 AHCI Port n 130 6 3 6 Remote Access Configuration 132 6 3 7 Trusted Computing 135 6 3 8 USB Configuration 136 6 3 8 1 USB Mass Storage Device Configuration 138 6 4 PCI PNP 141 6 5 BOOT 144 6 5 1...

Page 14: ...ASSEMBLY LANGUAGE SAMPLES 219 B 3 1 Enable the DIO Input Function 219 B 3 2 Enable the DIO Output Function 219 D 1 ADDRESS MAP 226 D 2 1ST MB MEMORY ADDRESS MAP 226 D 3 IRQ MAPPING TABLE 227 D 4 DMA...

Page 15: ...MI Chip to Chip Connection 19 Figure 2 9 Audio Connector 21 Figure 2 10 Intel 82566DM Gigabit LAN Connect Device 23 Figure 2 11 SATA Drive Connectors 26 Figure 2 12 Onboard USB Implementation 27 Figur...

Page 16: ...Pinout Locations 71 Figure 4 16 CEGC External Peripheral Interface Connector 72 Figure 4 17 RJ 45 Ethernet Connector 73 Figure 4 18 VGA Connector 74 Figure 5 1 Intel LGA775 Socket 83 Figure 5 2 Remov...

Page 17: ...12 Intel VGA Driver Setup Icon 170 Figure 7 13 GMA Driver Readme File 171 Figure 7 14 GMA Driver File Extraction 171 Figure 7 15 GMA Driver Installation Welcome Screen 172 Figure 7 16 GMA Driver Licen...

Page 18: ...44 Select the OS Version 192 Figure 7 45 Locate the Setup Program Icon 192 Figure 7 46 The InstallShield Wizard Starts 192 Figure 7 47 Preparing Setup Screen 193 Figure 7 48 InstallShield Wizard Welco...

Page 19: ...g Screen 205 Figure 7 65 Matrix Storage Manager License Agreement 206 Figure 7 66 Matrix Storage Manager Readme File 206 Figure 7 67 Matrix Storage Manager Setup Complete 207 Figure 7 68 IAMT Driver D...

Page 20: ...io Connector Pinouts 53 Table 4 5 DIO Connector Connector Pinouts 55 Table 4 6 12V Fan Connector Pinouts 56 Table 4 7 12V Fan Connector Pinouts 58 Table 4 8 Front Panel Connector Pinouts 14 pin 59 Tab...

Page 21: ...GC Series CyberResearch Inc xxi 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Table 5 2 Clear CMOS Jumper Settings 92 Table 5 3 Included Cables 95 Table 6...

Page 22: ...Menu 9 AHCI Configuration 129 Menu 10 AHCI Port n Configuration Menu 131 Menu 11 Remote Access Configuration Advanced 132 Menu 12 Trusted Computing 135 Menu 13 USB Configuration 136 Menu 14 USB Mass S...

Page 23: ...CyberResearch CPU Cards CEGC Series CyberResearch Inc 1 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com 1 Introduction Chapter 1...

Page 24: ...or 800 MHz un buffered DDR2 SDRAM DIMM are supported by the Mobile Intel Q35 graphics memory controller hub GMCH The Intel Q35 GMCH also has a single PCI Express x16 PCIe x16 expansion lane for a PCIe...

Page 25: ...45nm and 65nm o Intel Core 2 Quad 45nm and 65nm o Intel Celeron 65nm Supports four 240 pin 2GB 667MHz or 800 MHz DDR2 DIMMs Six SATA II drives with transfer rates of 3 0 Gbps supported Two Ultra ATA 1...

Page 26: ...CEGC has the following connectors on board 1 x ATX power connector 1 x Audio connector 1 x Digital input output DIO connector 2 x Fan connectors 1 x Front panel connector 1 x IDE disk drive connector...

Page 27: ...ications CEGC technical specifications are listed in Table Error No text of specified style in document 1 See Chapter 2 for details Specification CEGC Form Factor PICMG 1 3 System CPU LGA775 Intel Cor...

Page 28: ...n headers Two by external connectors Four through the backplane IDE One 40 pin IDE connector connects to two Ultra ATA33 66 100 133 devices SATA Six 3 0Gb s SATA II drives supported SATA RAID Levels R...

Page 29: ...n onboard pin header Fan Connector Three pin system fan pin header Four pin CPU fan pin header Buzzer Yes Power Consumption 3 3V 3A 5V 5 1A 12V 4 23A and 5VSB 0 28A 2 66 GHz E6700 Intel Core 2 Duo CPU...

Page 30: ...CEGC Series CyberResearch CPU Cards 8 Copyright 2008 CyberResearch Inc Intentionally Blank...

Page 31: ...CyberResearch CPU Cards CEGC Series CyberResearch Inc 9 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com 2 Detailed Specifications Chapter 2...

Page 32: ...th 338 58mm Width 126 39mm Figure Error No text of specified style in document 3 CEGC Dimensions mm 2 1 2 External Interface Panel Dimensions External peripheral interface connector panel dimensions a...

Page 33: ...ww cyberresearch com 2 2 Data Flow Figure Error No text of specified style in document 5 shows the data flow between the two on board chipsets and other components installed on the motherboard and des...

Page 34: ...3 3 Supported Intel Core 2 Duo Wolfdale Processors The Wolfdale core Intel Core 2 Duo CPU is a 45nm LGA775 processor 2 3 4 Supported Intel Core 2 Duo Conroe 2M Processors Table Error No text of speci...

Page 35: ...5 processors with the following features Execute Disable Bit Processor CPU Speed FSB Speed Cache Size 440 1 86 GHz 533 MHz 1 MB Table Error No text of specified style in document 3 Supported Intel Cor...

Page 36: ...Figure Error No text of specified style in document 6 Figure Error No text of specified style in document 6 Front Side Bus FSB 2 4 3 Intel Q35 Memory Controller The memory controller on the Intel Q35...

Page 37: ...g installed in the system please purchase two DIMM that have the same capacity and operating frequency Each DIMM socket can support DIMMs with the following specifications DDR2 only Un buffered only 6...

Page 38: ...e Intel Q35 PCIe bus is compliant with the PCI Express 1 1a Specifications has the following PCIe lanes One PCIe x16 graphics interface PCIe frequency of 1 25 GHz 2 5 Gbps in each direction For furthe...

Page 39: ...simultaneously with the IGD 2 4 6 Intel Q35 SDVO and Analog Display Features The Intel Q35 GMCH provides access to A progressive scan analog monitor An SDVO monitor 2 4 6 1 Intel Q35 SDVO Capabilities...

Page 40: ...V Out Only works with the IGD 3x3 Built In full panel scalar 180 degree Hardware screen rotation 270 MHz dot clock on each 12 bit interface Supports flat panels up to 2048 x 1536 60 Hz or digital CRT...

Page 41: ...ated 24 bit RAMDAC Up to 2048x1536 75 Hz refresh Hardware Color Cursor Support DDC2B Compliant Interface 2 4 7 Intel Q35 Direct Media Interface DMI The Direct Media Interface DMI is the communication...

Page 42: ...dication 2 5 Intel ICH9DO Southbridge Chipset 2 5 1 Intel ICH9DO Overview Intel ICH9DO Southbridge is an advanced I O controller hub ICH connected to the Intel Q35 Northbridge through a DMI connection...

Page 43: ...sfer rates up to 1 5 Gbps Supports twelve USB 2 0 devices with six UHCI controllers and two EHCI controller Complies with System Management Bus SMBus Specification Version 2 0 Supports Intel High Defi...

Page 44: ...OTE If an HDA audio kit is going to be installed on the backplane the HDA controller must be enabled in the BIOS settings To enable the HDA controller please refer to Section 0 the SouthBridge Configu...

Page 45: ...provide GbE access NOTE To enable the Intel ICH9DO GbE Wake on LAN function the Wake on LAN function must be enabled in the BIOS Please refer to Section 0 the SouthBridge Configuration menu on page 15...

Page 46: ...external RJ 45 Ethernet LAN connectors is interfaced to an Intel 82566DM Gigabit LAN connect device The Intel 82566DM is a compact single port integrated physical layer PHY device interfaced directly...

Page 47: ...PC Interface The ICH9DO LPC interface complies with the LPC 1 1 specifications The LPC bus from the ICH9DO is connected to the following components BIOS chipset Super I O chipset Trusted Platform Modu...

Page 48: ...g PCIe x1 lanes is connected to an Intel 82566DM GbE controller and the other PCIe x1 lane is connected to an Intel 82573L GbE controller For more detailed information please refer to Section 2 6 3 2...

Page 49: ...igure Error No text of specified style in document 13 Figure Error No text of specified style in document 13 SATA Drive Connectors 2 5 10 Intel ICH9DO Serial Peripheral Interface SPI BIOS The 4 pin SP...

Page 50: ...H9DO USB ports are implemented on the CEGC Two USB ports USB Port 1 and USB Port 2 are connected to two external connectors and six USB ports USB Port 3 to USB Port 8 are connected to three 8 pin onbo...

Page 51: ...raphics card on a compatible backplane Four PCIe x1 lanes are connected to four PCIe x1 expansion cards on a compatible backplane One PCIe x1 lanes are connected to two Intel PCIe GbE connectors One P...

Page 52: ...e connector 2 6 3 PCIe x1 Expansion Four of the six PCIe x1 expansion channels on the CEGC are interfaced to four PCIe x1 connectors on a backplane through an edge connector on the bottom of the CPU c...

Page 53: ...text of specified style in document 18 Intel 82573L PCIe GbE Controller Some of the features of the Intel 82573L are listed below 2 Gbps peak bandwidth per direction PCI Express Rev 1 0a specificatio...

Page 54: ...t 2 7 PCI Bus Components 2 7 1 PCI Bus Overview The PCI bus is connected to the components listed below ITE IT8211 ATA controller chipset IT8209R PCI arbiter PCI edge connector The PCI bus complies wi...

Page 55: ...512 bytes FIFO for data transfer per IDE channel Supports pre fetch and post write function for PIO mode 2 7 3 ITE IT8209 PCI Arbiter One of the Intel ICH9DO Southbridge PCI lanes is connected to an I...

Page 56: ...the ITE IT8209 PCI arbiter The PCI bus edge connector on the CEGC is interfaced to the PCI bus on the backplane thereby connecting the PCI backplane expansion boards to the Intel ICH9DO Southbridge T...

Page 57: ...ed style in document 22 TPM Connector The Intel ICH9DO Southbridge supports TPM version 1 1 and TPM version 1 2 devices for enhanced security Three TPM are available from CyberResearch The three TPMs...

Page 58: ...iTE IT8718F chipset are listed below PC98 99 2001 ACPI and LANDesk Compliant Enhanced Hardware Monitor Fan Speed Controller Multi curve for one fan control Multi sensor for one fan control Single 5V...

Page 59: ...al inputs VBAT internally and eight voltage monitor inputs These hardware parameters are reported in the BIOS and can be read from the BIOS Hardware Health Configuration menu 2 8 3 4 Super I O Fan Spe...

Page 60: ...as 16 programmable bits 8 bit input and 8 bit output 2 8 3 7 Super I O Infrared The Super I O has dedicated infrared IrDA pins that are interfaced to an IrDA connector The IrDA connector is compatible...

Page 61: ...is integrated on the Intel ICH9DO Southbridge and interfaced to the LAN2 RJ 45 Ethernet LAN connector through an Intel 82566DM Gigabit Platform LAN Connect device The Intel 82566DM is connected direct...

Page 62: ...T The CEGC Super I O Enhanced Hardware Monitor also monitors the following fan speeds Fan Speed1 CPU Fan Fan Speed2 System Fan The values for the above environmental parameters are all recorded in the...

Page 63: ...ent 4 shows the power consumption parameters for the CEGC running 3D Mark 2001 SE330 with a 2 66 GHz E6700 Intel Core 2 Duo processor with a 1066 MHz FSB and four 2 0GB 667MHz DDR2 DIMMs Voltage Curre...

Page 64: ...CEGC Series CyberResearch CPU Cards 42 Copyright 2008 CyberResearch Inc 3 Unpacking Chapter 3...

Page 65: ...Wear an anti static wristband Wearing a simple anti static wristband can help to prevent ESD from damaging the board Self grounding Before handling the board touch any grounded conducting material Du...

Page 66: ...ing please do not proceed with the installation Contact a CyberResearch sales representative directly To contact CyberResearch sales representative please send an email to sales cyberresearch com 3 3...

Page 67: ...3 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com 1 KB MS cable with Mini DIN 1 KB MS PS 2 Y cable 4 SATA cables 2 SATA power cables 1 Mini jumper Pack 1 Utility CD 1 USB cable Table Err...

Page 68: ...CEGC Series CyberResearch CPU Cards 46 Copyright 2008 CyberResearch Inc Audio kit 5 pin Wafer to PS 2 4 port USB cable CPU cooling kit CPU cooling kit Infineon TPM module Sinosun TPM module...

Page 69: ...ds CEGC Series CyberResearch Inc 47 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Winbond TPM module Table Error No text of specified style in document 6 P...

Page 70: ...CEGC Series CyberResearch CPU Cards 48 Copyright 2008 CyberResearch Inc 4 Connector Pinouts Chapter 4...

Page 71: ...ied style in document 25 shows the on board peripheral connectors rear panel peripheral connectors and on board jumpers Figure Error No text of specified style in document 25 Connector and Jumper Loca...

Page 72: ...nnector 7 pin SATA SATA3 Serial ATA drive connector 7 pin SATA SATA4 Serial ATA drive connector 7 pin SATA SATA5 Serial ATA drive connector 7 pin SATA SATA6 Serial port connector COM1 10 pin box heade...

Page 73: ...nel Connectors 4 2 Internal Peripheral Connectors Internal peripheral connectors are found on the motherboard and are only accessible when the motherboard is outside of the chassis This section has co...

Page 74: ...Copyright 2008 CyberResearch Inc Figure Error No text of specified style in document 26 ATX Power Connector Location PIN NO DESCRIPTION 1 GND 2 GND 3 12V 4 12V Table Error No text of specified style i...

Page 75: ...e CyberResearch HDA audio kit is optional If an HDA audio kit is required please contact a sales representative directly by sending an email to sales cyberresearch com The 9 pin audio connector is int...

Page 76: ...ified style in document 27 Audio Connector Location 9 pin PIN NO DESCRIPTION PIN NO DESCRIPTION 1 SYNC 2 BITCLK 3 SDOUT 4 PCBEEP 5 SDIN 6 RST 7 VCC 8 GND 9 12V 10 N C Table Error No text of specified...

Page 77: ...Type 18 pin header 2x9 CN Location See Figure Error No text of specified style in document 28 CN Pinouts See Table Error No text of specified style in document 11 The digital input output connector is...

Page 78: ...V Table Error No text of specified style in document 11 DIO Connector Connector Pinouts 4 2 4 Fan Connector CPU 12V 4 pin CN Label CPU_FAN1 CN Type 3 pin header CN Location See Figure Error No text of...

Page 79: ...643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 29 12V Fan Connector Location PIN NO DESCRIPTION 1 GND 2 12VCC 3 Rotation Signal 4 Co...

Page 80: ...Table Error No text of specified style in document 13 The system cooling fan connector provides a 12V 500mA current to a system cooling fan The connector has a rotation pin to get rotation signals fr...

Page 81: ...nt 13 12V Fan Connector Pinouts 4 2 6 Front Panel Connector 14 pin CN Label F_PANEL1 CN Type 12 pin header 2x6 CN Location See Figure Error No text of specified style in document 31 CN Pinouts See Tab...

Page 82: ...Connector Pinout Locations 14 pin FUNCTION PIN DESCRIPTION FUNCTION PIN DESCRIPTION 1 LED 2 SPEAKER 3 N C 4 N C Power LED 5 LED 6 N C 7 PWRBTSW Speaker 8 SPEAKER Power Button 9 PWRBTSW 10 N C 11 IDE...

Page 83: ...r 40 pin CN Label IDE1 CN Type 40 pin header 2x20 CN Location See Figure Error No text of specified style in document 32 CN Pinouts See Table Error No text of specified style in document 15 One 40 pin...

Page 84: ...C 21 IDE DRQ 22 GROUND 23 IOW 24 GROUND 25 IOR 26 GROUND 27 IDE CHRDY 28 GROUND 29 IDE DACK 30 GROUND DEFAULT 31 INTERRUPT 32 N C 33 SA1 34 N C 35 SA0 36 SA2 37 HDC CS0 38 HDC CS1 39 HDD ACTIVE 40 GR...

Page 85: ...5001 Branford CT USA www cyberresearch com The infrared interface connector supports both Serial Infrared SIR and Amplitude Shift Key Infrared ASKIR interfaces Figure Error No text of specified style...

Page 86: ...2 9 Keyboard Mouse Connector CN Label CN22 CN Type 6 pin header 1x6 CN Location See Figure Error No text of specified style in document 34 CN Pinouts See Table Error No text of specified style in doc...

Page 87: ...Cards CEGC Series CyberResearch Inc 65 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 34 Keyboard Mouse...

Page 88: ...ve Connectors CN Label SATA1 SATA2 SATA3 SATA4 SATA5 and SATA6 CN Type 7 pin SATA drive connectors CN Location See Figure Error No text of specified style in document 35 CN Pinouts See Table Error No...

Page 89: ...arch Inc 67 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 35 SATA Drive Connector Locations PIN NO DESC...

Page 90: ...tor COM1 COM 2 CN Label COM1 and COM2 CN Type 10 pin header 2x5 CN Location See Figure Error No text of specified style in document 36 CN Pinouts See Table Error No text of specified style in document...

Page 91: ...Cards CEGC Series CyberResearch Inc 69 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 36 Serial Connecto...

Page 92: ...I 9 Ground GND 10 N C Table Error No text of specified style in document 19 Serial Connector Pinouts 4 2 12 Trusted Platform Module TPM Connector CN Label TPM1 CN Type 40 pin header 2x20 CN Location S...

Page 93: ...F 203 643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 37 TPM Connector Pinout Locations PIN NO DESCRIPTION PIN NO DESCRIPTION 1 LCLK 2 GND2 3 LFRAME...

Page 94: ...SDVO1 CN Type 3 pin header 1x3 CN Location See Figure Error No text of specified style in document 38 CN Pinouts See Table Error No text of specified style in document 21 If an SDVO graphics card is...

Page 95: ...cified style in document 21 SDVO Connector Pinouts 4 2 14 USB Connectors Internal CN Label USB1 USB2 and USB3 CN Type 8 pin header 2x4 CN Location See Figure Error No text of specified style in docume...

Page 96: ...t of specified style in document 39 USB Connector Pinout Locations PIN NO DESCRIPTION PIN NO DESCRIPTION 1 VCC 2 GND 3 DATAN 4 DATAM 5 DATAN 6 DATAM 7 GND 8 VCC Table Error No text of specified style...

Page 97: ...specified style in document 40 CEGC External Peripheral Interface Connector 4 3 1 LAN Connectors CN Label LAN1 and LAN2 CN Type RJ 45 CN Location See Figure Error No text of specified style in docume...

Page 98: ...low LED indicates the port is linked See Table Error No text of specified style in document 24 STATUS DESCRIPTION STATUS DESCRIPTION ORANGE 10 100 LAN YELLOW Linked GREEN GbE LAN Table Error No text o...

Page 99: ...or No text of specified style in document 25 USB Port Pinouts 4 3 3 VGA Connector CN Label VGA1 CN Type 15 pin Female CN Location See Figure Error No text of specified style in document 40 CN Pinouts...

Page 100: ...rror No text of specified style in document 42 VGA Connector PIN DESCRIPTION PIN DESCRIPTION 1 RED 2 GREEN 3 BLUE 4 NC 5 GND 6 GND 7 GND 8 GND 9 VCC NC 10 GND 11 NC 12 DDC DAT 13 HSYNC 14 VSYNC 15 DDC...

Page 101: ...CyberResearch CPU Cards CEGC Series CyberResearch Inc 79 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Intentionally Blank...

Page 102: ...CEGC Series CyberResearch CPU Cards 80 Copyright 2008 CyberResearch Inc 5 Installation Chapter 5...

Page 103: ...therefore critical that whenever the CEGC or any other electrical component is handled the following anti static precautions are strictly adhered to Wear an anti static wristband Wearing a simple ant...

Page 104: ...tallation instructions described in this manual should be carefully followed in order to prevent damage to the CEGC CEGC components and injury to the user Before and during the installation please DO...

Page 105: ...or its components 5 2 2 Installation Checklist The following checklist is provided to ensure the CEGC is properly installed All the items in the packing list are present The CPU is installed The CPU c...

Page 106: ...ts listed in the checklist in Chapter 3 are missing please do not proceed with the installation Contact a CyberResearch sales representative directly To contact a sales representative please send an e...

Page 107: ...requires meeting all of the platform requirements listed below CPU An Intel Pentium 4 Processor with HT Technology must be installed Chipset An Intel Chipset that supports HT Technology that has been...

Page 108: ...llow the steps below WARNING When handling the CPU only hold it on the sides DO NOT touch the pins at the bottom of the CPU Step 1 Remove the protective cover Remove the black protective cover by pryi...

Page 109: ...Figure Error No text of specified style in document 45 Figure Error No text of specified style in document 45 Open the CPU Socket Load Plate Step 3 Inspect the CPU socket Make sure there are no bent...

Page 110: ...d engage the load lever by pushing it back to its original position Secure the load lever under the retention tab on the side of CPU socket Step 9 Connect the CPU 12V cable to the 12After the cooling...

Page 111: ...er of thermal paste on the bottom of the heat sink The thermal paste between the CPU and the heat sink is important for optimum heat dissipation To install the cooling kit follow the instructions belo...

Page 112: ...oard Step 5 Tighten the screws Use a screwdriver to tighten the four screws Tighten each nut a few turns at a time and do not over tighten the screws Step 6 Connect the fan cable Connect the cooling k...

Page 113: ...w ONLY purchase DDR2 DIMM Have a frequency of 667 MHz or 800 MHz Have a maximum capacity of 2 0 GB If more than one DDR2 DIMM is being installed in the system please purchase DIMM that have the same c...

Page 114: ...CEGC Series CyberResearch CPU Cards 92 Copyright 2008 CyberResearch Inc...

Page 115: ...socket Step 3 DIMM2 Install the third DDR2 DIMM into the DIMM2 DDR2 DIMM socket Step 4 DIMM4 Install the fourth DDR2 DIMM into the DIMM4 DDR2 DIMM socket Step 0 5 4 3 3 DIMM Installation Guidelines T...

Page 116: ...e Error No text of specified style in document 50 Step 4 Removing a DIMM To remove a DIMM push both handles outward The memory module is ejected by a mechanism in the socket Step 0 5 5 Jumper Settings...

Page 117: ...ied style in document 28 Jumper Location See Figure Error No text of specified style in document 51 If the CEGC fails to boot due to improper BIOS settings the clear CMOS jumper clears the CMOS data a...

Page 118: ...CMOS Setup Default Short 2 3 Clear CMOS Setup Table Error No text of specified style in document 28 Clear CMOS Jumper Settings The location of the clear CMOS jumper is shown in Figure Error No text o...

Page 119: ...o travel through the heat sink surface In a system with an individual power supply unit the cooling fan of a power supply can also help generate airflow through the board surface NOTE CyberResearch ha...

Page 120: ...backplane carefully align the CPU card interface connectors with the corresponding socket on the backplane To do this please refer to the reference material that came with the backplane Next secure t...

Page 121: ...ed above please refer to Chapter 3 Installation of the accessories listed above are described in detail below 5 7 2 ATA Flat Cable Connection The ATA 66 100 flat cable connects to the CEGC to one or t...

Page 122: ...pin 1 on the connectorStep 0 5 7 3 Audio Kit Installation An optional audio kit that is separately ordered connects to the 9 pin audio connector on the CEGC The audio kit consists of five audio jacks...

Page 123: ...t Connection Step 3 Connect the audio devices Connect the speakers and the subwoofer to the appropriate audio jack shown in Figure Error No text of specified style in document 53 Step 0 5 7 4 Dual RS...

Page 124: ...Cable Installation Step 3 Secure the bracket The dual RS 232 connector has two D sub 9 male connectors secured on a bracket To secure the bracket to the chassis please refer to the reference material...

Page 125: ...or See Figure Error No text of specified style in document 55 Figure Error No text of specified style in document 55 SATA Drive Cable Connection Step 3 Connect the cable to the SATA disk Connect the c...

Page 126: ...onnectors The locations of the USB connectors are shown in Chapter 3 WARNING If the USB pins are not properly aligned the USB device can burn out Step 2 Align the connectors The cable has two connecto...

Page 127: ...o secure the bracket to the chassis please refer to the installation instructions that came with the chassis Step 0 5 8 Installing Devices on a PICMG 1 3 Backplane Compatible PICMG 1 3 backplanes can...

Page 128: ...ice cable connectors VGA device cable connectors To install these devices connect the corresponding cable connector from the actual device to the corresponding CEGC external peripheral interface conne...

Page 129: ...8 LAN Connection Step 7 Insert the LAN cable RJ 45 connector Once aligned gently insert the LAN cable RJ 45 connector into the onboard RJ 45 connector Step 0 5 9 2 PS 2 Y Cable Connection NOTE Before...

Page 130: ...e the dual PS 2 connector The location of the PS 2 connector is shown in Chapter 3 Step 2 Insert the keyboard mouse connector Insert the PS 2 connector on the end of the PS 2 y cable into the external...

Page 131: ...ice please follow the instructions below Step 1 Located the USB connectors The locations of the USB connectors are shown in Chapter 4 Step 2 Align the connectors Align the USB device connector with on...

Page 132: ...A connector Align the male DB 15 connector on the VGA screen cable with the female DB 15 connector on the external peripheral interface Step 3 Insert the VGA connector Once the connectors are properly...

Page 133: ...CyberResearch CPU Cards CEGC Series CyberResearch Inc 111 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com...

Page 134: ...CEGC Series CyberResearch CPU Cards 112 Copyright 2008 CyberResearch Inc 6 BIOS Screens Chapter 6...

Page 135: ...Press the DELETE key when the Press Del to enter SETUP message appears on the screen 0 If the message disappears before the DELETE key is pressed restart the computer and try again 6 1 2 Using Setup...

Page 136: ...6 1 4 Unable to Reboot After Configuration Changes If the computer cannot boot after changes to the system configuration is made CMOS defaults Use the jumper described in Chapter 5 6 1 5 BIOS Menu Ba...

Page 137: ...entered The Main menu gives an overview of the basic system information BIOS Menu 1 Main System Overview The System Overview lists a brief summary of different system components The fields in System O...

Page 138: ...to set the system time Manually enter the hours minutes and seconds System Date xx xx xx Use the System Date option to set the system date Manually enter the day month and year 6 3 Advanced Use the A...

Page 139: ...www cyberresearch com ACHI Configuration See Section 6 3 5 1 Remote Access Configuration see Section 6 3 6 Trusted Computing see Section 6 3 5 USB Configuration see Section 6 3 7 BIOS Menu 2 Advanced...

Page 140: ...anufacturer Lists the name of the CPU manufacturer Frequency Lists the CPU processing speed FSB Speed Lists the FSB speed Cache L1 Lists the CPU L1 cache size Cache L2 Lists the CPU L2 cache size Rati...

Page 141: ...on Enhanced Use the SATA n BIOS option to enable the nth SATA drive port Enhanced DEFAULT The nth SATA drive port is activated Disabled The nth SATA drive port is disabled Configure SATA n as IDE Use...

Page 142: ...status of the auto detected IDE devices The following IDE devices are detected and are shown in the IDE Configuration menu Primary IDE Master Primary IDE Slave Secondary IDE Master Secondary IDE Slave...

Page 143: ...of the selected IDE disk drive The drive parameters are listed as follows Device Lists the device type e g hard disk CD ROM etc Type Indicates the type of devices a user can manually select Vendor Lis...

Page 144: ...Type Auto Use the Type BIOS option select the type of device the AMIBIOS attempts to boot from after the Power On Self Test POST is complete Not Installed BIOS is prevented from searching for an IDE...

Page 145: ...Block Multi Sector Transfer to disable or enable BIOS to auto detect if the device supports multi sector transfers Disabled BIOS is prevented from using Multi Sector Transfer on the specified channel...

Page 146: ...e specifications of the drive DMA Mode Auto Use the DMA Mode BIOS selection to adjust the DMA mode options Auto DEFAULT BIOS auto detects the DMA mode Use this value if the IDE disk drive support cann...

Page 147: ...ransfer rate of 66 6MBps To use this mode it is required that an 80 conductor ATA cable is used UDMA5 Ultra DMA mode 5 selected with a maximum data transfer rate of 99 9MBps To use this mode it is req...

Page 148: ...se 32 bit data transfers on supported hard disk drives 6 3 3 Super IO Configuration Use the Super IO Configuration menu BIOS Menu 6 to set or change the configurations for the FDD controllers parallel...

Page 149: ...Serial Port1 Mode Normal Use the Serial Port1 Mode option to select the transmitting and receiving mode for the first serial port Normal DEFAULT Serial Port 1 mode is normal IrDA Serial Port 1 mode is...

Page 150: ...t the Serial Port2 operational mode Normal DEFAULT Serial Port 2 mode is normal IrDA Serial Port 2 mode is IrDA ASK IR Serial Port 2 mode is ASK IR 6 3 4 Hardware Health Configuration The Hardware Hea...

Page 151: ...must be set by the user PWM Manual mode Pulse width modulation set manually When the CPU FAN 1 Mode Setting option is in the Automatic Mode the following parameters can be set CPU Temp Limit of OFF C...

Page 152: ...Start 020 WARNING Setting this value too high may cause the fan to start only when the CPU is at a high temperature and therefore cause the system to be damaged The CPU Temp Limit of Start option can...

Page 153: ...emperature exceeds the temperature specified in this option the fan starts to rotate at full speed To select a value select the CPU Temp Limit of Full option and enter a decimal number between 000 and...

Page 154: ...rease in temperature A list of available options is shown below 0 PWM 1 PWM 2 PWM 4 PWM 8 PWM 16 PWM 32 PWM 64 PWM The following system parameters and values are shown The system parameters that are m...

Page 155: ...onfiguration menu BIOS Menu 8 to select the ACPI state when the system is suspended BIOS Menu 8 Advanced ACPI Configuration Suspend Mode S1 POS Use the Suspend Mode option to specify the sleep state t...

Page 156: ...r Interface AHCI is a new programming interface for SATA host controllers AHCI systems do not have master slave designation for SATA devices each device is treated as a master and hardware assisted na...

Page 157: ...eed longer periods of time before they are ready The time out options are 0 seconds 5 seconds 10 seconds 15 seconds DEFAULT 20 seconds 25 seconds 30 seconds 35 seconds AHCI Port n Not Detected Use the...

Page 158: ...ive connected to SATA drive connector n Auto DEFAULT Automatically detects the drive type connected to the system Not Installed Specifies no device is connected to the serial port n S M A R T Enabled...

Page 159: ...on the drive connected to SATA drive connector n on the system 6 3 6 Remote Access Configuration Use the Remote Access Configuration menu BIOS Menu 11 to configure remote access parameters The Remote...

Page 160: ...T Terminal Type VT UTF8 Combo Key Support Sredir Memory Display Delay These configuration options are discussed below Serial Port Number COM1 Use the Serial Port Number option to select the serial por...

Page 161: ...n 1 NOTE Identical baud rate setting musts be set on the host a management computer running a terminal software and the slave Redirection After BIOS POST Always Use the Redirection After BIOS POST op...

Page 162: ...type is VT UTF8 6 3 7 Trusted Computing Use the Trusted Computing menu to configure settings related to the Trusted Computing Group TCG Trusted Platform Module TPM BIOS Menu 12 Trusted Computing TCG...

Page 163: ...learing the TPM option to clear the information stored in the TPM 6 3 8 USB Configuration Use the USB Configuration menu BIOS Menu 13 to read USB configuration information and configure the USB settin...

Page 164: ...Ports DEFAULT The USB configuration is 6x6 ports USB 2 0 Controller Enabled The USB 2 0 Controller BIOS option enables or disables the USB 2 0 controller Disabled USB function disabled Enabled DEFAULT...

Page 165: ...e connected USB2 0 Controller Mode HiSpeed Use the USB2 0 Controller Mode option to set the speed of the USB2 0 controller FullSpeed The controller is capable of operating at 12Mb s HiSpeed DEFAULT Th...

Page 166: ...Delay option to set the number of seconds POST waits for the USB mass storage device after the start unit command 10 Sec POST waits 10 seconds for the USB mass storage device after the start unit comm...

Page 167: ...provided by the BIOS must match for a device to boot properly If both types do not match then device s behavior is undefined To make sure both types match format the device using BIOS INT13h calls aft...

Page 168: ...ues of 80h or above CDROM Assumes the CD ROM is formatted as bootable media All the devices that support block sizes greater than 512 bytes can only be booted using this option 6 4 PCI PnP Use the PCI...

Page 169: ...CyberResearch CPU Cards CEGC Series CyberResearch Inc 147 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com BIOS Menu 15 PCI PnP Configuration...

Page 170: ...ces Reserved The specified IRQ is reserved for use by Legacy ISA devices Available IRQ addresses are IRQ3 IRQ4 IRQ5 IRQ7 IRQ9 IRQ10 IRQ 11 IRQ 14 IRQ 15 DMA Channel Available Use the DMA Channel optio...

Page 171: ...7 Reserved Memory Size Disabled Use the Reserved Memory Size BIOS option to specify the amount of memory that should be reserved for legacy ISA devices Disabled DEFAULT No memory block reserved for le...

Page 172: ...s CyberResearch CPU Cards 150 Copyright 2008 CyberResearch Inc BIOS Menu 16 Boot 6 5 1 Boot Settings Configuration Use the Boot Settings Configuration menu BIOS Menu 17 to configure advanced system bo...

Page 173: ...figuration Quick Boot Enabled Use the Quick Boot BIOS option to make the computer speed up the boot process Disabled No POST procedures are skipped Enabled DEFAULT Some POST procedures are skipped to...

Page 174: ...Num Lock On Use the Bootup Num Lock BIOS option to specify if the number lock setting must be modified during boot up Off Does not enable the keyboard Number Lock automatically To use the 10 keys on t...

Page 175: ...troller to boot the system Disabled Cannot be booted from a remote system through the Intel 82573L PCIe GbE controller Enabled DEFAULT Can be booted from a remote system through the Intel 82573L PCIe...

Page 176: ...ttings 6 5 3 Hard Disk Drives Use the Hard Disk Drives menu to specify the boot sequence of the available HDDs When the menu is opened the HDDs connected to the system are listed as shown below 1st Dr...

Page 177: ...d to the system are shown For example if only two HDDs are connected only 1st Drive and 2nd Drive are listed The boot sequence from the available devices is selected If the 1st Drive option is selecte...

Page 178: ...OS Menu 20 Security Change Supervisor Password Use the Change Supervisor Password to set or change a supervisor password The default for this option is Not Installed If a supervisor password must be i...

Page 179: ...s field and enter the password After the password has been added Install appears next to Change User Password Clear User Password Use the Clear User Password to clear a user s password The default for...

Page 180: ...earch CPU Cards 158 Copyright 2008 CyberResearch Inc BIOS Menu 21 Chipset 6 7 1 NorthBridge Chipset Configuration Use the NorthBridge Chipset Configuration menu BIOS Menu 22 to configure the Northbrid...

Page 181: ...bled Use the Memory Remap Feature option to allow the overlapped PCI memory above the total physical memory to be remapped Enabled DEFAULT Overlapped PCI memory can be remapped Disabled Overlapped PCI...

Page 182: ...option to select the graphics controller used as the primary boot device Select either an integrated graphics controller IGD or a combination of PCI graphics controller a PCI express PEG controller or...

Page 183: ...ridge Configuration Use the SouthBridge Configuration menu BIOS Menu 23 to configure the Southbridge chipset BIOS Menu 23 SouthBridge Chipset Configuration GbE Controller Enabled Use the GbE Controlle...

Page 184: ...s not preserved by the hardware The system must be restarted to return to the Working state Disabled DEFAULT Southbridge GbE controller cannot rouse the system from an S5 sleep state Enabled Southbrid...

Page 185: ...er Off DEFAULT The system remains turned off Power On The system turns on Last State The system returns to its previous state If it was on it turns itself on If it was off it remains off 6 8 Exit Use...

Page 186: ...out saving the changes made to the system Discard Changes Use the Discard Changes option to discard the changes and remain in the BIOS configuration setup program Load Optimal Defaults Use the Load Op...

Page 187: ...CyberResearch CPU Cards CEGC Series CyberResearch Inc 165 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Intentionally Blank...

Page 188: ...CEGC Series CyberResearch CPU Cards 166 Copyright 2008 CyberResearch Inc 7 Software Drivers Chapter 7...

Page 189: ...e installed on the system Intel chipset driver LAN driver Audio driver Installation instructions are given below 7 2 Driver CD Auto run All the drivers for the CEGC are on the CD that came with the sy...

Page 190: ...search Inc Figure Error No text of specified style in document 62 Introduction Screen Step 3 Click Install Drivers then click on the CEGC CPU Card Step 4 A new screen with a list of available drivers...

Page 191: ...lect the driver to install from the list in Figure Error No text of specified style in document 63 Detailed driver installation instructions follow below Step 0 7 3 Intel Chipset Driver To install the...

Page 192: ...d style in document 64 Step 4 The window in Figure Error No text of specified style in document 65 appears Figure Error No text of specified style in document 65 Intel Chipset Driver Setup Icon Step 5...

Page 193: ...rd CT USA www cyberresearch com Figure Error No text of specified style in document 66 Intel Package Manager Step 7 The Intel Setup Welcome screen See Figure Error No text of specified style in docume...

Page 194: ...The Intel license agreement in appears Figure Error No text of specified style in document 68 Intel Chipset Driver License Agreement Step 10 Accept the terms and conditions by clicking YES Step 11 Th...

Page 195: ...plete screen appears See Figure Error No text of specified style in document 70 Figure Error No text of specified style in document 70 Intel Chipset Driver Complete Installation Screen Step 15 To comp...

Page 196: ...ure Error No text of specified style in document 71 Select the Operating System Step 3 Select the operating system from those shown in Figure Error No text of specified style in document 71 Step 4 A n...

Page 197: ...643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 72 Intel Driver Directory Step 5 Click the directory icon in Figure Error No text of specified style...

Page 198: ...o text of specified style in document 73 Intel VGA Driver Setup Icon Step 7 Click on the VGA driver installation icon in See Figure Error No text of specified style in document 73 Step 8 The Readme in...

Page 199: ...s Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 74 GMA Driver Readme File Step 9 Click NEXT to extract the GMA driv...

Page 200: ...PU Cards 178 Copyright 2008 CyberResearch Inc Figure Error No text of specified style in document 75 GMA Driver File Extraction Step 10 The welcome screen shown in Figure Error No text of specified st...

Page 201: ...203 643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 76 GMA Driver Installation Welcome Screen Step 11 To continue the installation process click NEX...

Page 202: ...k the YES in Figure Error No text of specified style in document 77 to continue Step 14 The installation notice shown in Figure Error No text of specified style in document 78 appears Figure Error No...

Page 203: ...16 After selecting when to restart the computer in Figure Error No text of specified style in document 79 click FINISH Step 0 7 5 Intel 82566 Gigabit LAN Connect Device Driver To install the Intel 82...

Page 204: ...ure Error No text of specified style in document 80 Intel 82566 Driver Directory Icon Step 3 Click on the Intel 82566DM directory icon in Figure Error No text of specified style in document 80 Step 4...

Page 205: ...text of specified style in document 81 Intel 82566 Operating System Step 5 Select the Operating System in Figure Error No text of specified style in document 81 Step 6 The window in Figure Error No te...

Page 206: ...earch CPU Cards 184 Copyright 2008 CyberResearch Inc Figure Error No text of specified style in document 82 Select Operating System Type Step 8 The window in Figure Error No text of specified style in...

Page 207: ...A window containing the Intel 82566 driver startup icon appears See Figure Error No text of specified style in document 84 Figure Error No text of specified style in document 84 Intel 82566 Device Dr...

Page 208: ...in document 85 Intel 82566 Welcome Screen Step 15 The license agreement in Figure Error No text of specified style in document 86 appears Figure Error No text of specified style in document 86 Intel...

Page 209: ...No text of specified style in document 87 appears next Figure Error No text of specified style in document 87 Intel 82566 Driver Setup Options Step 18 Select the required installation configuration i...

Page 210: ...ation Ready Window Step 20 Click INSTALL in Figure Error No text of specified style in document 88 Step 21 The program starts to install the driver The window in appears Figure Error No text of specif...

Page 211: ...w the steps below Step 1 Select LAN from the list in Figure Error No text of specified style in document 63 Step 2 The window in Figure Error No text of specified style in document 90 appears Figure E...

Page 212: ...Intel 82573 Operating System Step 5 Select the Operating System in Figure Error No text of specified style in document 91 Step 6 The window in Figure Error No text of specified style in document 92 ap...

Page 213: ...25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 92 Select Operating System Type Step 8 The window in Figu...

Page 214: ...ent 83 Step 10 A window containing the Intel 82573 driver startup icon appears See Figure Error No text of specified style in document 93 Figure Error No text of specified style in document 94 Intel 8...

Page 215: ...CT USA www cyberresearch com Figure Error No text of specified style in document 95 Intel 82573 License Agreement Step 13 Accept the license terms and agreements in and click NEXT to continue Step 14...

Page 216: ...tep 15 Click NEXT to continue Step 16 The driver begins to extract the installation files See Figure Error No text of specified style in document 97 Figure Error No text of specified style in document...

Page 217: ...www cyberresearch com Figure Error No text of specified style in document 98 Intel PRO Network Connections window Step 18 Click INSTALL DRIVERS in Figure Error No text of specified style in document...

Page 218: ...Step 21 A new License Agreement appears See Figure Error No text of specified style in document 100 Figure Error No text of specified style in document 100 License Agreement Step 22 Accept the terms a...

Page 219: ...anford CT USA www cyberresearch com Figure Error No text of specified style in document 101 Setup Type Step 24 Select the setup type in Figure Error No text of specified style in document 101 and clic...

Page 220: ...be installed if an external audio kit with a RealTek ALC883 codec is installed 7 7 1 BIOS Setup Step 1 Enter the BIOS setup To do this reboot the system and press DEL during POST Step 2 Go to the Sou...

Page 221: ...5000 F 203 643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 103 Select the Audio CODEC Step 3 Double click the ALC883 folder Step 4 Double click the a...

Page 222: ...ds 200 Copyright 2008 CyberResearch Inc Figure Error No text of specified style in document 104 Select the OS Step 5 Double click the appropriate operating system version folder Figure Error No text o...

Page 223: ...ess Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 105 Select the OS Version Step 6 Double click the Setup exe progr...

Page 224: ...Program Icon Step 7 The InstallShield Wizard starts Figure Error No text of specified style in document 107 Figure Error No text of specified style in document 107 The InstallShield Wizard Starts Step...

Page 225: ...Figure Error No text of specified style in document 108 Preparing Setup Screen Step 9 Once initialized the InstallShield Wizard welcome screen appears Figure Error No text of specified style in docum...

Page 226: ...install the new software as shown in Figure Error No text of specified style in document 110 Figure Error No text of specified style in document 110 Audio Driver Software Configuration Step 12 The In...

Page 227: ...ears Figure Error No text of specified style in document 112 Figure Error No text of specified style in document 112 Restart the Computer Step 14 The confirmation screen offers the option of restartin...

Page 228: ...CPU Cards 206 Copyright 2008 CyberResearch Inc Figure Error No text of specified style in document 113 Access Windows Control Panel Step 2 Double click the System icon Figure Error No text of specifi...

Page 229: ...siness Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 114 Double Click the System Icon Step 3 Click the Device Manag...

Page 230: ...208 Copyright 2008 CyberResearch Inc Figure Error No text of specified style in document 115 Double Click the Device Manager Tab Step 4 A list of system hardware devices appears Figure Error No text...

Page 231: ...T USA www cyberresearch com Figure Error No text of specified style in document 116 Device Manager List Step 5 Double click the listed device that has question marks next to it This means Windows does...

Page 232: ...re Error No text of specified style in document 117 Search for Suitable Driver Step 7 Select Search for a suitable driver for my device recommended and click NEXT to continue Step 8 The Locate Driver...

Page 233: ...No text of specified style in document 119 in the location browsing window where X is the system CD drive Figure Error No text of specified style in document 119 Location Browsing Window Step 11 Sele...

Page 234: ...berResearch Inc Figure Error No text of specified style in document 120 SATA RAID Driver Installation Program Step 3 Double click the INTEL folder Step 4 Double click the iata62_cd exe program icon in...

Page 235: ...0 F 203 643 5001 Branford CT USA www cyberresearch com Figure Error No text of specified style in document 121 SATA RAID Setup Program Icon Step 5 Figure Error No text of specified style in document 1...

Page 236: ...08 CyberResearch Inc Figure Error No text of specified style in document 122 InstallShield Wizard Setup Screen Step 6 Figure Error No text of specified style in document 123 shows the Matrix Storage M...

Page 237: ...age Manager Setup Screen Step 7 Figure Error No text of specified style in document 124 shows the Matrix Storage Manager welcome screen Figure Error No text of specified style in document 124 Matrix S...

Page 238: ...n Step 9 Click NEXT and a license agreement appears Figure Error No text of specified style in document 126 Figure Error No text of specified style in document 126 Matrix Storage Manager License Agree...

Page 239: ...igure Error No text of specified style in document 127 appears Figure Error No text of specified style in document 127 Matrix Storage Manager Readme File Step 11 Read the Readme file information and c...

Page 240: ...to restart the computer Step 0 7 10 Intel Active Management Technology Driver Installation To install the Intel Active Management Technology IAMT driver please follow the steps below Step 1 Select iA...

Page 241: ...www cyberresearch com specified style in document 130 appears Figure Error No text of specified style in document 130 IAMT Driver Installation Icon Step 4 Double click the setup icon in Figure Error N...

Page 242: ...n document 131 IAMT Welcome Screen Step 6 Click NEXT to continue The License Agreement in Figure Error No text of specified style in document 132 appears Figure Error No text of specified style in doc...

Page 243: ...USA www cyberresearch com Step 8 The IAMT Readme file in Figure Error No text of specified style in document 133 appears Figure Error No text of specified style in document 133 IAMT Readme File Step 9...

Page 244: ...p Operations Step 11 When the Setup Operations in Figure Error No text of specified style in document 134 are complete the window in Figure Error No text of specified style in document 135 appears Fig...

Page 245: ...CyberResearch CPU Cards CEGC Series CyberResearch Inc 223 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Intentionally Blank...

Page 246: ...CEGC Series CyberResearch CPU Cards 224 Copyright 2008 CyberResearch Inc A BIOS Options Appendix A...

Page 247: ...Large Mode Auto 118 Block Multi Sector Transfer Auto 118 PIO Mode Auto 118 DMA Mode Auto 119 S M A R T Auto 120 32Bit Data Transfer Enabled 120 Serial Port1 Address 3F8 IRQ4 121 Serial Port1 Mode Nor...

Page 248: ...ways 134 Terminal Type ANSI 134 TCG TPM Support No 135 Clearing the TPM Press Enter 136 USB Functions 12 USB Ports 136 USB Port Configure 6X6 USB Ports 137 USB 2 0 Controller Enabled 137 Legacy USB Su...

Page 249: ...52 Memory Remap Feature Enabled 154 Memory Hole At 15M 16M Disabled 154 Initiate Graphic Adapter 155 Internal Graphics Mode Select Enable 8MB 155 GbE Controller Enabled 156 GbE LAN Boot Disabled 157 G...

Page 250: ...CEGC Series CyberResearch CPU Cards 228 Copyright 2008 CyberResearch Inc B DIO Interface Appendix B...

Page 251: ...ing table describes how the DIO connector pins are connected to the Super I O GPIO port 1 Pin Description Super I O Pin Super I O Pin Description 1 Input 0 19 GP30 General purpose I O port 3 bit 0 2 O...

Page 252: ...BIOS interrupt call INT 15H controls the digital I O An assembly program to enable digital I O input functions is listed below MOV AX 6F08H Sets the digital port as input INT 15H Initiates the INT 15...

Page 253: ...CyberResearch CPU Cards CEGC Series CyberResearch Inc 231 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Intentionally Blank...

Page 254: ...CEGC Series CyberResearch CPU Cards 232 Copyright 2008 CyberResearch Inc C Watchdog Timer Appendix C...

Page 255: ...o a known state A BIOS function call INT 15H is used to control the Watchdog Timer INT 15H AH 6FH Sub function AL 2 Sets the Watchdog Timer s period BL Time out value Its unit second is dependent on t...

Page 256: ...Timer otherwise the system resets Example program INITIAL TIMER PERIOD COUNTER W_LOOP MOV AX 6F02H setting the time out value MOV BL 30 time out value is 48 seconds INT 15H ADD THE APPLICATION PROGRA...

Page 257: ...CyberResearch CPU Cards CEGC Series CyberResearch Inc 235 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Intentionally Blank...

Page 258: ...CEGC Series CyberResearch CPU Cards 236 Copyright 2008 CyberResearch Inc D Address Mapping Appendix D...

Page 259: ...er 0A0 0A1 Interrupt Controller 0C0 0DF DMA Controller 0F0 0FF Numeric data processor 1F0 1F7 Primary IDE Channel 2F8 2FF Serial Port 2 COM2 378 37F Parallel Printer Port 1 LPT1 3B0 3BB Intel Graphics...

Page 260: ...COM2 IRQ11 LAN USB2 0 SATA IRQ4 COM1 IRQ12 PS 2 mouse IRQ5 SMBus Controller IRQ13 FPU IRQ6 FDC IRQ14 Primary IDE IRQ7 Available IRQ15 Secondary IDE Table E 4 IRQ Mapping Table D 4 DMA Channel Assignm...

Page 261: ...CyberResearch CPU Cards CEGC Series CyberResearch Inc 239 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Intentionally Blank...

Page 262: ...CEGC Series CyberResearch CPU Cards 240 Copyright 2008 CyberResearch Inc E Intel Matrix Storage Manager Appendix E...

Page 263: ...CAUTION A configured RAID volume which may consist of multiple hard drives appears to an operating system as a contingent storage space The operating system will not be able to distinguish the physica...

Page 264: ...er To access the Intel Matrix Storage Manager please follow the steps below Step 1 Connect SATA drives to the system Connect two or more SATA drives to the system Make sure the drives have the same ca...

Page 265: ...ge Manager to configure the RAID array Brief descriptions of configuration options are given below Step 7 Install the OS After the RAID array has been configured install the OS To do this please refer...

Page 266: ...name for the RAID volume or press ENTER to accept the default volume name Upper and lower case alphabetic numeric space and underscore characters are all applicable for naming an array See Figure E 2...

Page 267: ...ord CT USA www cyberresearch com NOTE RAID 0 and RAID1 levels require a minimum of two hard drives RAID 10 level requires a minimum of four hard drives RAID5 level requires a minimum of three hard dri...

Page 268: ...E 4 Select the Stripe Size Step 5 Enter the Volume Capacity Enter the volume capacity or press ENTER to accept the default capacity See Figure E 5 Figure E 5 Enter the Volume Capacity Step 6 Create th...

Page 269: ...43 5001 Branford CT USA www cyberresearch com Figure E 6 Create the RAID Volume Step 7 Create RAID Volume Verification After reading the warning press Y to create the RAID volume as specified or N to...

Page 270: ...on the member drives of a RAID volume are destroyed during the RAID deletion process Make sure any data to be saved has been moved or backed up before deleting a RAID volume Step 1 Select Delete RAID...

Page 271: ...me to be deleted and press ENTER See Figure E 9 Figure E 9 Select RAID Volume to be Deleted Step 3 Delete Volume Verification After reading the warning press Y to delete the specified RAID volume or N...

Page 272: ...n RAID WARNING All data stored on the disk drive of a RAID volume is destroyed when resetting it to non RAID Make sure any data to be saved has been moved or backed up before resetting a disk to non R...

Page 273: ...ks to Reset Use the arrow keys to scroll through the disk drives and press SPACE to select which drives are to be reset as non RAID After all the disks to be reset have been chosen press ENTER See Fig...

Page 274: ...atus After the disk drives have been reset the Matrix Storage Manager Main menu is shown indicating the status of the RAID volumes and disk drives See Figure E 15 Step 0 Figure E 15 Disk Drive and RAI...

Page 275: ...usiness Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com Figure E 16 Exit Menu Step 2 Exit Verification Press Y to exit the Matrix Storage Manager or N to return to the M...

Page 276: ...CEGC Series CyberResearch CPU Cards 254 Copyright 2008 CyberResearch Inc Intentionally Blank...

Page 277: ...tings and possibly change settings before reinstalling the modules 3 Have a volt meter handy to take measurements of the signals you are trying to measure as well as the signals on the board module or...

Page 278: ...CEGC Series CyberResearch CPU Cards 244 Copyright 2008 CyberResearch Inc Intentionally Blank...

Page 279: ...d the sole and exclusive liability of the Seller its successors or assigns in connection with equipment purchased and in lieu of all other warranties expressed implied or statutory including but not l...

Page 280: ...CEGC Series CyberResearch CPU Cards 246 Copyright 2008 CyberResearch Inc Intentionally Blank...

Page 281: ......

Page 282: ...CyberResearch Inc 25 Business Park Drive Branford CT 06405 USA P 203 483 8815 F 203 483 9024 www cyberresearch com...

Reviews: