User’s Manual 

CPS600E 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

CyberPower Europe   

CyberPower Systems B.V.   
Flight Forum 3545, 5657DW Eindhoven, The Netherlands 
Tel: +31 (0)40 2348170 
Fax: +31 (0)40 2340314 
Website: http://eu.cyberpowersystems.com/

   

E-mail: [email protected] 

 

 

K01-0000186-00 

 

Summary of Contents for CPS600E

Page 1: ...0E CyberPower Europe CyberPower Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands Tel 31 0 40 2348170 Fax 31 0 40 2340314 Website http eu cyberpowersystems com E mail sales cyberpower eu...

Page 2: ...ACKING 4 AUTOMATIC VOLTAGE REGULATOR 4 HARDWARE INSTALLATION GUIDE 4 BASIC OPERATION 5 DESCRIPTION 5 REPLACING THE BATTERY 6 DEFINITIONS FOR ILLUMINATED LCD 7 EPS STATUS INQUIRY AND FUNCTIONS SETUP 8...

Page 3: ...he CE requirement CAUTION The building wiring socket outlet shockproof socket outlet must be easily accessible and close to the EPS CAUTION Please use only VDE tested CE marked mains cable e g the mai...

Page 4: ...EN 62040 2 Category C2 Radiated Emission IEC EN 62040 2 Category C2 Harmonic Current IEC EN61000 3 2 Voltage Fluctuations and Flicker IEC EN61000 3 3 EMS IEC EN61000 4 2 ESD IEC EN61000 4 3 RS IEC EN6...

Page 5: ...the EPS into a 2 pole 3 wire grounded receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands e...

Page 6: ...Inquiry and Functions Setup section for more details 5 AC Outlet The unit has one Schuko type outlet for connected equipment to ensure temporary uninterrupted operation during a power failure Max Out...

Page 7: ...es regarding proper disposal of batteries Lead acid batteries should be recycled CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION...

Page 8: ...ays normal line mode AVR mode and battery backup mode 3 NORMAL MODE Icon This icon will illuminate when the EPS is working under normal conditions 4 ON BAT On Battery Icon When a severe brownout or bl...

Page 9: ...nctions User configurable functions are as follows a Delay Time The time delay between switching from Battery Mode to Line Mode There are 9 different settings The default setting is 0 minute Function...

Page 10: ...to select the robust mode setting 1 and using the computers is suggested to select the standard mode setting 2 The settable items are sorted by unit as in the following table Step 3 Press and hold th...

Page 11: ...y and the alarm reacts during the machine shut down LCD Warning Display Alarm Condition Solution Over Load Icon Constant tone Over Load Output Off Load exceed the rating of EPS Check total load to con...

Page 12: ...ct CyberPower Systems at service cyberpower eu com Batteries are discharged Recharge the unit for at least 4 hours Unit has been damaged by a surge or spike Contact CyberPower Systems about replacemen...

Page 13: ...0 230Vac On Battery Output Frequency 50 60 Hz 1 Overload Protection On Utility Fuse On Battery Internal Current Limiting Transfer Time 10 ms Typical Output Receptacles Schuko Type 1 External Battery V...

Page 14: ...CPS600E Copyright 2010 CyberPower Systems Inc 13...

Page 15: ...CPS600E Copyright 2010 CyberPower Systems Inc 14...

Page 16: ...Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands Tel 31 0 40 2348170 Fax 31 0 40 2340314 Website http eu cyberpowersystems com E mail sales cyberpower eu com Entire contents copyright 2...