CPS600E 

 

Copyright © 2010 CyberPower Systems, Inc.

 

 

5

 

BASIC OPERATION

 

DESCRIPTION 

 
 
 
 
 
 
 
 
 

 

1. Power Switch 

Used as the master on/off switch for equipment connected to the AC outlet. 

2. Power On Indicator 

This LED is above the power switch. It illuminates when the utility condition is normal and the AC outlet 
is providing power, free of surges and spikes. 

3. Multifunction LCD Readout 

High resolution and intelligent LCD display shows all the EPS information with icons and messages. 
For more information please check the DEFINITIONS FOR ILLUMINATED LCD INDICATORS section. 

4. LCD Display Toggle / Selected Switch 

Users can monitor EPS status and set up functions using the toggle. The buzzer on/off can also be 
controlled by the toggle switch. Please refer to “EPS Status Inquiry and Functions Setup” section for 
more details. 

5. AC Outlet 

The  unit  has  one  Schuko  type  outlet  for  connected  equipment  to  ensure  temporary  uninterrupted 
operation during a power failure. Max. Output is 6.3A; Max. Output wattage is 420W. 

Note! Maximum cord length is 10 meters and the cable O.D. must be 14AWG or greater. 

6. AC Inlet 

Connect to utility power through the input power cord. 

Note

The O.D. of the distribution cables must be 0.75mm or greater. 

Input Fuse

 

The fuse provides optimal overload protection. 

Note

The Input Fuse is 6.3A/250V.

 

7. Black Battery Cable (Negative (-)) 

Connect black (negative (-)) battery cable to the black (negative (-)) connector on the external battery. 

Note: The Battery cable is 10AWG / 4 feet. 

8. Red Battery Cable (Positive (+)) 

Connect red (positive (+)) battery cable to the red (positive (+)) connector on the external battery. 

Note: The Battery cable is 10AWG / 4 feet. 

9. DC Fuse 

The fuse provides optimal overload protection for battery mode operation. 

 
 

 

 

 

Summary of Contents for CPS600E

Page 1: ...0E CyberPower Europe CyberPower Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands Tel 31 0 40 2348170 Fax 31 0 40 2340314 Website http eu cyberpowersystems com E mail sales cyberpower eu...

Page 2: ...ACKING 4 AUTOMATIC VOLTAGE REGULATOR 4 HARDWARE INSTALLATION GUIDE 4 BASIC OPERATION 5 DESCRIPTION 5 REPLACING THE BATTERY 6 DEFINITIONS FOR ILLUMINATED LCD 7 EPS STATUS INQUIRY AND FUNCTIONS SETUP 8...

Page 3: ...he CE requirement CAUTION The building wiring socket outlet shockproof socket outlet must be easily accessible and close to the EPS CAUTION Please use only VDE tested CE marked mains cable e g the mai...

Page 4: ...EN 62040 2 Category C2 Radiated Emission IEC EN 62040 2 Category C2 Harmonic Current IEC EN61000 3 2 Voltage Fluctuations and Flicker IEC EN61000 3 3 EMS IEC EN61000 4 2 ESD IEC EN61000 4 3 RS IEC EN6...

Page 5: ...the EPS into a 2 pole 3 wire grounded receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands e...

Page 6: ...Inquiry and Functions Setup section for more details 5 AC Outlet The unit has one Schuko type outlet for connected equipment to ensure temporary uninterrupted operation during a power failure Max Out...

Page 7: ...es regarding proper disposal of batteries Lead acid batteries should be recycled CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION...

Page 8: ...ays normal line mode AVR mode and battery backup mode 3 NORMAL MODE Icon This icon will illuminate when the EPS is working under normal conditions 4 ON BAT On Battery Icon When a severe brownout or bl...

Page 9: ...nctions User configurable functions are as follows a Delay Time The time delay between switching from Battery Mode to Line Mode There are 9 different settings The default setting is 0 minute Function...

Page 10: ...to select the robust mode setting 1 and using the computers is suggested to select the standard mode setting 2 The settable items are sorted by unit as in the following table Step 3 Press and hold th...

Page 11: ...y and the alarm reacts during the machine shut down LCD Warning Display Alarm Condition Solution Over Load Icon Constant tone Over Load Output Off Load exceed the rating of EPS Check total load to con...

Page 12: ...ct CyberPower Systems at service cyberpower eu com Batteries are discharged Recharge the unit for at least 4 hours Unit has been damaged by a surge or spike Contact CyberPower Systems about replacemen...

Page 13: ...0 230Vac On Battery Output Frequency 50 60 Hz 1 Overload Protection On Utility Fuse On Battery Internal Current Limiting Transfer Time 10 ms Typical Output Receptacles Schuko Type 1 External Battery V...

Page 14: ...CPS600E Copyright 2010 CyberPower Systems Inc 13...

Page 15: ...CPS600E Copyright 2010 CyberPower Systems Inc 14...

Page 16: ...Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands Tel 31 0 40 2348170 Fax 31 0 40 2340314 Website http eu cyberpowersystems com E mail sales cyberpower eu com Entire contents copyright 2...

Reviews: