background image

 

POE Clock Messages

Operations Guide

931080C

CyberData Corporation

18

2.1.5 Reboot

POE Clock will accept a UDP Broadcast to port 10004 to reboot. If the ReBoot packet is accepted, 
POE Clock responds by sending a Confirmation packet to the IP and Port which sent the ReBoot 
packet. If the Change packet is rejected, POE Clock responds with a Rejection packet.

Device >

Host

<XML>\n

<PacketType>Confirmation</PacketType>\n

<VendorName>CyberData</VendorName>\n

<ProductName>CDNetDevice</ProductName>\n

<ProductType>CDPOEClock</ProductType>\n

<MacAddr>00:50:C2:02:0F:0D</MacAddr>\n

<SerialNum>313000001</SerialNum>\n

<Request>Change</Request>\n

</XML>\n

Change

Accepted

Device >

Host

<XML>\n

<PacketType>Rejection</PacketType>\n

<VendorName>CyberData</VendorName>\n

<ProductName>CDNetDevice</ProductName>\n

<ProductType>CDPOEClock</ProductType>\n

<MacAddr>00:50:C2:02:0F:0D</MacAddr>\n

<SerialNum>313000001</SerialNum>\n

<Request>Change</Request>\n

</XML>\n

Change

Rejected

Table 2-4. Change – DHCP IP (continued)

Table 2-5. Reboot  

From >

To

Content

Comment

Host >

Device

<XML>\n

<PacketType>ReBoot</PacketType>\n

<VendorName>CyberData</VendorName>\n

<ProductName>CDNetDevice</ProductName>\n

<ProductType>CDPOEClock</ProductType>\n

<DevName>CDPOEClock0001</DevName>\n

<MacAddr>00:50:C2:02:0F:0D</MacAddr>\n

<SerialNum>313000001</SerialNum>\n

</XML>\n

Reboot 
Request

Summary of Contents for 011313

Page 1: ...PoE Digital Clock Operations Guide Part 011313 Document Part 931080C for Firmware Version 1 2 3 31 CyberData Corporation 3 Justin Court Monterey CA 93940 831 373 2601 The IP Endpoint Company...

Page 2: ...make changes without notice to this manual and to any such product software firmware and or hardware OPEN SOURCE STATEMENT Certain software components included in CyberData products are subject to the...

Page 3: ...2 Error Codes Adds the following note to Section 1 3 Installation Upon installation of the clock please place the shunt over JP1 A shunt is left hanging next to the coin cell Browsers Supported The fo...

Page 4: ...hat is a safety policy or protection of property The safety guidelines for the equipment in this manual do not purport to address all the safety issues of the equipment It is the responsibility of the...

Page 5: ...on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Refer all servicing t...

Page 6: ...ation Dump Response 21 2 1 8 Load Configuration Command 23 2 1 9 Load Configuration Response 24 2 2 TCP Messages Definition 25 2 2 1 Clock Status Request 25 2 2 2 Clock Configuration Command 25 2 2 3...

Page 7: ...32 SerialNum 32 2 3 33 SubnetMask 32 2 3 34 Time 32 2 3 35 TZ 32 2 3 36 VendorName 32 2 3 37 __DATE__ 32 2 3 38 __TIME__ 32 2 4 Change Log 32 Appendix 1 Troubleshooting Technical Support A 1 Frequentl...

Page 8: ...is a memory corruption The device should correct this when it is synced with NTP E 02 which means no battery or low battery This means that the JP 1 has not been connected or it could also mean that t...

Page 9: ...y Main Dialog Operations Guide 931080C CyberData Corporation 2 1 4 Main Dialog Double click on the configuration utility shortcut to open the configuration utility program The Main Dialog shown in Fig...

Page 10: ...k Configure Button Selecting a PoE Digital Clock from the Device Log and clicking this button will open the Network Configuration Dialog see Section 1 6 Network Configuration Dialog for the selected P...

Page 11: ...re is only one PoE Digital Clock connected to the LAN If there were more PoE Digital Clocks on the LAN they would appear as a list of PoE Digital Clocks The final PoE Digital Clock discovered is autom...

Page 12: ...ialog Click on the Network Configure Button to go to the Network Configuration Dialog see Figure 1 4 The Network Configuration Dialog allows you to configure the PoE Digital Clock name and LAN connect...

Page 13: ...et Mask and Default Gateway settings available for static IP configuration Command Port In the event the default command port conflicts with other applications using the LAN it can be changed to anoth...

Page 14: ...5 is not checked then the following Network Configuration Static IP Dialog appears for static IP configuration Note Note that IP Address Subnet Mask and Default Gateway fields Figure 1 5 are now enabl...

Page 15: ...l send configuration changes to PoE Digital Clock then cause PoE Digital Clock to reboot and connect to the LAN with the corrected configuration This may take several seconds A warning dialog appears...

Page 16: ...timekeeping functionality Date Time Time Zone Daylight Saving and automatic NTP update of the PoE Digital Clock are configured in the Test Monitor Dialog 12 24 hour mode colon appearance and brightne...

Page 17: ...to propagate PoE Clock configuration from one to many clocks The configuration file used as input to the Configuration Load command must be prepared by software familiar with details of the infrastru...

Page 18: ...configuration may be manually entered here Clicking the Configure button presents a dialog Enter the values for DST Offset DST Begin and DST End and then click on the OK button Note Enter zero values...

Page 19: ...utton Note Until the OK button is clicked on the Set Date Time dialog none of the format colon intensity time zone daylight saving NTP configuration values have been committed to the PoE Digital Clock...

Page 20: ...roadcasts a UDP Discover Response to the port from which the request was received Table 2 1 Discover From To Content Comment Host Device XML n PacketType Request PacketType n VendorName CyberData Vend...

Page 21: ...4 DHCP Enabled DHCP n DNSHostName CDPOEClock DNSHostName n Announce 0 Announce n S2_SR 0x14 LISTEN S2_SR n DHCPLease 126176 DHCPLease n FirmWareVer 1 2 2 14 FirmWareVer n __DATE__ Apr 14 2015 __DATE__...

Page 22: ...Announce PacketType n VendorName CyberData VendorName n ProductName CDNetDevice ProductName n ProductType CDPOEClock ProductType n MacAddr 00 50 C2 02 0F 0D MacAddr n SerialNum 313000001 SerialNum n...

Page 23: ...CyberData VendorName n ProductName CDNetDevice ProductName n ProductType CDPOEClock ProductType n MacAddr 00 50 C2 02 0F 0D MacAddr n SerialNum 313000001 SerialNum n DevName CDPOEClock0001 DevName n I...

Page 24: ...uctType CDPOEClock ProductType n MacAddr 00 50 C2 02 0F 0D MacAddr n SerialNum 313000001 SerialNum n Request Change Request n XML n Change Rejected Table 2 3 Change Static IP continued Table 2 4 Chang...

Page 25: ...2 02 0F 0D MacAddr n SerialNum 313000001 SerialNum n Request Change Request n XML n Change Accepted Device Host XML n PacketType Rejection PacketType n VendorName CyberData VendorName n ProductName CD...

Page 26: ...tType n MacAddr 00 50 C2 02 0F 0D MacAddr n SerialNum 313000001 SerialNum n Request ReBoot Request n XML n Reboot Accepted Device Host XML n PacketType Rejection PacketType n VendorName CyberData Vend...

Page 27: ...ould issue a Dump Configuration command to POE Clock then store the Configuration Dump response for later input to a Load Configuration command to POE Clocks that have not yet been configured If Stati...

Page 28: ...ock ProductType n MacAddr 00 50 C2 02 0F 0D MacAddr n SerialNum 313000001 SerialNum n Sequence 0 Sequence n DevName CDPOEClock0001 DevName n IPAddr 192 168 6 23 IPAddr n CMDPort 30998 CMDPort n Subnet...

Page 29: ...80C CyberData Corporation 22 NTPURL 0 pool ntp org NTPURL n NTPEpoch 1 01 1900 NTPEpoch n FirmWareVer 1 2 3 18 FirmWareVer n __DATE__ Apr 18 2015 __DATE__ n __TIME__ 10 46 47 __TIME__ n XML n Table 2...

Page 30: ...ketType n VendorName CyberData VendorName n ProductName CDNetDevice ProductName n ProductType CDPOEClock ProductType n MacAddr 00 50 C2 02 0F 0D MacAddr n SerialNum 313000001 SerialNum n Sequence 1 Se...

Page 31: ...ME__ n XML n Table 2 8 Load Configuration Command continued Table 2 9 Load Configuration Response From To Content Comment Device Host XML n PacketType Confirmation PacketType n VendorName CyberData Ve...

Page 32: ...PacketType ClockQuery PacketType n XML n Status Request Device Host XML n PacketType ClockStatus PacketType n Intensity Auto Intensity n Colon Flash Colon n Format 24 Format n Time 16 43 19 Time n TZ...

Page 33: ...d PacketType n Intensity Auto Intensity n Colon Flash Colon n Format 24 Format n Time 17 49 34 Time n TZ UTC 8 00 TZ n DSTOF 1 00 DSTOF n DSTBE M3 2 0 02 00 00 M11 1 0 02 00 00 DSTBE n Date 04 18 2015...

Page 34: ...300C9465300C9475300C94B0305D n 100060000C9441310C9468310C9474310C94843124 n 100080000C9417320C9427320C943732800100001F n 1000A00000933A0DFF24F4BEF4BE0FE500936000D1 n 1000C0003C0D0C9429120895721B680D00...

Page 35: ...ks are connected to a LAN Announce is a UDP Broadcast to port 10004 2 3 3 Battery Information only value sensed by the battery voltage sensor 2 3 4 CMDPort Configurable TCP Listen Port Default 30998 a...

Page 36: ...y an endpoint 2 3 13 DSTBE Configurable Daylight Saving begin and end expressed in a POSIX like format For example M3 2 0 02 00 00 M11 1 0 02 00 01 specifies Daylight Saving begin at Month 3 week 2 Su...

Page 37: ...light sensor to automatically adjust brightness 2 3 20 MacAddr POE Clock MAC Address is assigned at manufacture 2 3 21 NTPEpoch Configurable value specifying NTP epoch POE Clock expects NTP Version 3...

Page 38: ...t tag in all packets identifies a packet and its function 2 3 27 ProductName Identifies a CyberData CDNetDevice assigned at manufacture 2 3 28 ProductType Identifies the CyberData product type assigne...

Page 39: ...in 24 hour format HH MM SS 2 3 35 TZ Configurable Time Zone expressed as an offset from UTC For example California USA time zone is 08 00 Moscow Russia time zone is 03 00 Accurate configuration of thi...

Page 40: ...ked questions for your product click on the FAQs tab at the following webpage http www cyberdata net voip 011313 Documentation The documentation for this product is released in an English language ver...

Page 41: ...support cyberdata net The Support Form initiates a ticket which CyberData uses for tracking customer requests Most importantly the Support Form tells us which PBX system and software version that you...

Page 42: ...ta contact information B D Device Log 3 Discovery Progress Bar 3 Discovery Scan Button 3 F Firmware Load 10 M Main Dialog 2 messages definitions 25 P Progress Bar 3 S sales B service B T TCP messages...

Reviews: