PoE Digital Clock Configuration Utility
Test Monitor Dialog
Operations Guide
931080C
CyberData Corporation
11
Intensity
Click on the
More
or
Less
buttons to roll through the range of desired intensity. Dim is the
least intense. 1 through 15 selects a range of brightness. Auto uses an ambient light sensor
to automatically adjust brightness.
Use Host TZ, DST, Date & Time
Check this box for convenience of using the Windows Host settings for these configuration
items. Time Zone, Daylight Saving, Date & Time configuration will be taken from the Host
Pc and automatically updated on the dialog.
Time Zone
UTC offset may be manually configured here, +/- UTC, hours and minutes.
Daylight Saving
The Daylight Saving configuration may be manually entered here. Clicking the
Configure
button presents a dialog.
Enter the values for
DST Offset
,
DST Begin
, and
DST End
, and then click on the
OK
button.
Note
: Enter zero values for minutes and hours to disable the automatic Daylight Saving
adjustment.
NTP Update
Check the
Update
box and enter the frequency in hours of the automatic time adjustment
from and NTP server. Enter an NTP server URL or an IP address of an NTP server. Be
aware that if a URL is specified, PoE Digital Clock uses the DNS Server IPs from the
network configuration dialog to locate the NTP server by URL.
Check the
Now
box to test NTP update immediately.
The PoE Digital Clock device accepts “NTP Version 3 answers” from NTP servers. NTP
Epoch should not be changed unless it is certain that the NTP server being addressed uses
another Epoch.
Table 1-3. Test Monitor Dialog Items (continued)
Item
Function