4.10 Servicing Instructions.
The following servicing procedure should be carried out on an annual basis and
only by a qualified person.
Note: foreign bodies which can gather on the surface of the burner unit. It is
inevitable that servicing can be a dusty operation. Suitable precautions should be
taken.
Before commencing and servicing, ensure that the gas is turned off to the
appliance and that the appliance is cool.
Servicing procedure
Step 1: Turn off the fire and allow it to cool.
Step 2: Remove the Fascia.
Step 3: Turn off the electric supply.
Step 4: Turn off the gas supply at the isolation tap.
Step 5: Disconnect the gas pipe from the valve. Lift the burner clear
of the fire surround.
Step 6: Clean all gas components and check electrical parts are
secure also checking for damage.
Step 7: Using a soft brush remove any debris from the top surface of
the fire unit.
Step 8: Re-assemble, and connect the gas and electric supply.
Step 9: Check for gas soundness.
Step 10:Check that any purpose-provided ventilation is free from
obstruction.
Step 11:Re-commission the fire as described in ‘Commissioning the fire’.
Summary of Contents for Flueless Fire Pod