Page 5 of 31
Remote Control Information
Read through this section before starting the installation
The installation should only be carried out by a Gas Safe Registered fitter
and in accordance with national and local regulations for both gas &
electricity. The installation must also be in accordance with the relevant
parts of local and national building regulations. For the Republic of Ireland,
reference should be made to IS 813 and ICP3 and any guidance notes from
Bord Gais.
Failure to have the fire fitted by a qualified person will invalidate the
Warranty, and CVO Fire will not accept any claims for incorrect
installation.
Power Supply
230v AC-15%+10%, 50/60 Hz
Max power consumption
20VA cos 0.6 (Peak)
Stand-by power consumption
1W
Ambient Temperature
0.80 C
Protection
IP 20
Humidity
Max 95% at 40c
Electrical protection
Not required
Connections
STELVIO/STOCKO
Waiting time for demand
3-5 seconds typically
Ignition Time
20 seconds typically
Ignition Frequency
1Hz
Spark gap
Max 6mm
Ignition Cable length
500mm
A mains connection is required close to the fireplace-a 0.7m cable is
provided for this purpose with a special plug connected to the burner
control box. A 3amp socket may be used, or a fused spur outlet can be
purpose provided. The colour code of the mains is as follows:
Green/Yellow =
EARTH :
Brown =
LIVE :
Blue =
NEUTRAL
The appliance must be in a position so that the mains supply is
accessible for routine maintenance.
A 3amp fused should be fitted in the plug of fused spur.
WARNING – This Appliance Must be Earthed