Page 11 of 31
The installer must check that all of the combustion products are
entering the flue after 10 minutes by traversing the perimeter of the
fireplace using a smoke (match).
If you have any questions, or the fire is not operating correctly,
please contact the CVO Technical team
BEFORE
you leave the
installation. As part of our Customer Service procedure you will be
asked for the Fire Serial number [front cover] and Gas Safe
Registration.
If the appliance is not fitted in strict accordance with these
instructions this will invalidate the Warranty, and CVO Fire will not
accept any claims for incorrect installation. CVO Fire cannot be held
responsible for any damage caused due to incorrect installation and
reserve the right to charge for any corrective work.
Re-setting the Appliance
Hand Held Remote Unit
To start your appliance, press both buttons on the hand-held remote
unit, hold them down for a minimum of three seconds until the ignition
process begins which will run for 19-20 seconds before it turns onto the
main burner. After the burner has ignited, it can then be switched to
high or low using the one on the right side of the handset.
Wall Mounted Remote Switch
Unlike the hand held unit, you are only required to press one switch.
Press the left switch for 2 – 3 seconds. The ignition sequence will
continue for 20 seconds before the burner is ignited to high flame
position. The right button is only for turning the fire from high to low
setting and vice versa.
Warning - This Appliance Must be Earthed
Please Note:
The remote system is supplied with both the hard-wired
wall mounted switch and infrared system as standard.
Both options allow full control of the fire. Both options can be used in
tandem. Alternatively the infrared can be used without the wall-mounted
switch; vice versa the wall-mounted switch can be used with out the
infrared system.
It is very important when removing one option or the other that it is done
correctly in order for the option left to function correctly on its own.