Cutler-Hammer IQ Analyzer Quick Start Manual Download Page 9

From Main Menu
Press and Release

Program PB

Press Up (F2), then

Enter (F4) to input

default password

10000

Program Mode

Top Level Menu

Displayed

Press and Release

Select (F1) PB

Use F1-F4 PBs to
Move and Select

Change Date/Time

Use F1-F3 PBs to
Move and Select

Parameter to Change

Use F1-F4 PBs to 

Establish and Enter

Desired Data

Press Program

PB to Exit 

Program Mode

Top Level Entry Screen

Displayed

Incorrect Password Exits

Program Mode

Automatically

General Setup

Blinking

Type of System

Blinking

Month

Blinking

Parameter Digit

Blinking

Parameter

Blinking

Time/Date Programming Example

Password Programming Example

From Main Menu

Press and Release

Program PB

Press Up (F2), then

Enter (F4) to input

default password

10000

Program Mode

Top Level Menu

Displayed

Press and Release

Select (F1) PB

Use F1-F4 PBs to
Move and Select

Change Password

Use F1-F4 PBs to 

Establish and Enter 

New Password

Press Program

PB to Exit 

Program Mode

Top Level Entry Screen

Displayed

Incorrect Password Exits

Program Mode

Automatically

General Setup

Blinking

Type of System

Blinking

5 Digit Password

Displayed

Changed Password

Blinking

17

Summary of Contents for IQ Analyzer

Page 1: ...Cutler Hammer IQ Analyzer START QUICKSTART GUIDE...

Page 2: ...lly understand the wide array of features offered by your IQ Analyzer it is strongly recommended that operators read the User s Manual Following initial power up of the IQ Analyzer the displayed Meter...

Page 3: ...ol relaying analog inputs outputs and communications capabilities It will replace dozens of existing individual meters recorders and relays The IQ Analyzer displays a comprehensive list of metered par...

Page 4: ...nager PGM DISPMGR CUST 7 Display Mode USER S MANUAL SECTIONS 5 2 The IQ Analyzer monitors and displays a compre hensive list of metered parameters The Meter Menu provides easy access using Up Down PBs...

Page 5: ...and information Note on Sign Convention USER S MANUAL SECTIONS 5 22 As a factory default lagging vars and power factor are represented as negative values at the load This is a negative sign convention...

Page 6: ...ent damage The only exception is when connecting disconnecting ribbon cables at J2 or J3 11 Wiring installation for the IQ Analyzer must follow a suitable Wiring Plan Drawing and conform to applicable...

Page 7: ...___________ Change Password Enter new 5 digit password if required __ __ __ __ __ General Setup Settings Worksheet 13 Quick Start Procedure USER S MANUAL SECTIONS 4 5 During initial setup of your IQ A...

Page 8: ...SECTION 6 Meter a typical load on a 480 volt 3 phase 3 wire ABC phase rotation 60Hz system with 1200 5 CTs 50 5 ground CTs and no PTs Assume Kilowatt hour energy resolution and lagging vars Power Fac...

Page 9: ...Setup Blinking Type of System Blinking Month Blinking Parameter Digit Blinking Parameter Blinking Time Date Programming Example Password Programming Example From Main Menu Press and Release Program P...

Page 10: ...r Re enter program setpoints using proper password Customer established or factory default 44444 or 10000 1 I O Fuse Littlefuse Plug in Microfuse Catalog 273 250 0 25A 125V or equivalent Troubleshooti...

Page 11: ...Cutler Hammer For additional information or technical assistance contact ADVANCED PRODUCT SUPPORT CENTER 1 800 809 2772 www cutlerhammer eaton com...

Reviews: