Operator Panel 

(USER’S MANUAL SECTION 3)

Up/Down: Maneuver through metered 
values in Display Mode.

Home: Return to Display Mode from other
modes. Toggle between Current and Demand
in Meter Menu.  

F1-F4: Used to enter analysis modes. Used 
to maneuver in program, analysis and reset
m o d e s .

Previous Level: Moves up one level in 
hierarchy (e.g., in Program mode from
PGM/GEN/TYPE to PGM/GEN).

R e s e t : Enter/Exit Reset mode.

P r o g r a m : Enter/Exit Program mode.

H e l p : Enter/Exit Help menu.

Push Buttons (PBs)

(USER’S MANUAL SECTIONS 3&4)

Up/Down

PBs

5

Function

LEDs

Display
Window

Help PB

Program PB

Meter
Menu

(F1-F4)

Previous Level

Home

Function

PBs

Introduction 

Introduction

The IQ Analyzer is a compact, panel mount-
ed, micro-processor based device for users
who want to monitor all aspects of their
electrical distribution system. It has been
engineered to provide comprehensive
metering, power quality analysis, remote
input monitoring, control relaying, analog
inputs/outputs and communications 
capabilities. It will replace dozens of existing
individual meters, recorders, and relays. 

The IQ Analyzer displays a comprehensive
list of metered parameters, historical values,
harmonic profiles, peak demands and alarm
data. Custom screens may be easily pro-
grammed to conveniently view parameter
groupings, or to concurrently observe rela-
tionships as system conditions change.
Information display options and device pro-
gramming are accessible through a commu-
nications port via IMPACC 

( I n t e g r a t e d

Monitoring Protection and Control
C o m m u n i c a t i o n s )

, or directly at the Operator

Panel using Meter Menu and Function Keys.

The IQ Analyzer directly monitors 3-phase
lines to 600 Vac without the need for 
external potential transformers.  Above 600
Vac, external transformers are required.

The device complies with rigid ANSI C12.16
Class 10 revenue meter accuracy standards,
and provides true rms readings through the
50th harmonic. Accuracy is maintained in
applications with high distortion levels,
including systems exhibiting 3.0 Crest
F a c t o r .

(USER’S MANUAL SECTIONS 1&2)

Summary of Contents for IQ Analyzer

Page 1: ...Cutler Hammer IQ Analyzer START QUICKSTART GUIDE...

Page 2: ...lly understand the wide array of features offered by your IQ Analyzer it is strongly recommended that operators read the User s Manual Following initial power up of the IQ Analyzer the displayed Meter...

Page 3: ...ol relaying analog inputs outputs and communications capabilities It will replace dozens of existing individual meters recorders and relays The IQ Analyzer displays a comprehensive list of metered par...

Page 4: ...nager PGM DISPMGR CUST 7 Display Mode USER S MANUAL SECTIONS 5 2 The IQ Analyzer monitors and displays a compre hensive list of metered parameters The Meter Menu provides easy access using Up Down PBs...

Page 5: ...and information Note on Sign Convention USER S MANUAL SECTIONS 5 22 As a factory default lagging vars and power factor are represented as negative values at the load This is a negative sign convention...

Page 6: ...ent damage The only exception is when connecting disconnecting ribbon cables at J2 or J3 11 Wiring installation for the IQ Analyzer must follow a suitable Wiring Plan Drawing and conform to applicable...

Page 7: ...___________ Change Password Enter new 5 digit password if required __ __ __ __ __ General Setup Settings Worksheet 13 Quick Start Procedure USER S MANUAL SECTIONS 4 5 During initial setup of your IQ A...

Page 8: ...SECTION 6 Meter a typical load on a 480 volt 3 phase 3 wire ABC phase rotation 60Hz system with 1200 5 CTs 50 5 ground CTs and no PTs Assume Kilowatt hour energy resolution and lagging vars Power Fac...

Page 9: ...Setup Blinking Type of System Blinking Month Blinking Parameter Digit Blinking Parameter Blinking Time Date Programming Example Password Programming Example From Main Menu Press and Release Program P...

Page 10: ...r Re enter program setpoints using proper password Customer established or factory default 44444 or 10000 1 I O Fuse Littlefuse Plug in Microfuse Catalog 273 250 0 25A 125V or equivalent Troubleshooti...

Page 11: ...Cutler Hammer For additional information or technical assistance contact ADVANCED PRODUCT SUPPORT CENTER 1 800 809 2772 www cutlerhammer eaton com...

Reviews: