background image

Preface

III

Support Services

It is Cutler-Hammer’s goal to ensure your greatest possible satisfaction with the operation of our
products. We are dedicated to providing fast, friendly, and accurate assistance. That is why we offer
you so many ways to get the support you need. Whether it’s by phone, fax, modem, or mail, you can
access Cutler-Hammer support information 

24 hours a day, seven days a week

. Our wide range of

services include:

Technical Support

VOICE 1-800-809-2772
FAX 614-882-0417
EMAIL [email protected]

If you are in the U.S. or Canada, you can take advantage of our toll-free line for technical assistance
with hardware and software product selection, system design and installation, and system debugging
and diagnostics. Technical support engineers are available for calls during regular business hours
(8 am - 5:30 pm EST) by calling 1-800-809-2772. International calls can be made to either the Tech Line at
1-800-809-2772 (toll call) or the Cutler-Hammer main business line at 614-882-3282.  You can contact our
technical support engineers by faxing your support requests directly to the Advanced Product Support
Center (APSC) located in Columbus, Ohio at 614-882-0417.  You can also contact our technical support
engineers by emailing your support requests to [email protected].

Emergency Technical Support

VOICE 1-800-809-2772

Because machines do not run on a nine-to-five schedule, we offer emergency after-hours technical
support. A technical support engineer can be paged for emergencies involving plant down situations or
safety issues. Emergency support calls are automatically routed directly to our answering service
after-hours (5:30 pm - 8 am EST) and weekends. For emergency technical support, call 1-800-809-2772.

Note that the Emergency Technical Support phone number does not currently support product repairs
or shipping outside normal business hours.

Information Fax-Back Service

FAX 614-899-5323

The latest Cutler-Hammer product information, specifications, technical notes and company news is
available to you via fax through our direct document request service at 614-899-5323. Using a touch-
tone phone, you can select any of the info faxes from our automated product literature and technical
document library, punch in a fax number and receive the information immediately.

If you have Internet capabilities, you also have access to technical support via our website at
http://www.cutlerhammer.eaton.com/automation. The website includes technical notes, frequently
asked questions, release notes, and other technical documentation. This direct technical support
connection also offers you the ability to request assistance and exchange software files electronically.

Bulletin Board Service

MODEM 614-899-5209

Parameters: 8 data bits, 1 stop bit, parity none, 9600-28.8K baud

If you have modem access, you can dial in directly to our electronic bulletin board service for the latest
product and company information. File sharing, product software downloads and our user message
service are just a few of the things you will find online at 614-899-5209.

Summary of Contents for EATON PanelMate ControlNet

Page 1: ...Eaton Corporation Cutler Hammer Group 811 Greencrest Drive Columbus OH 43081 PanelMate ControlNet CommunicationDriver Manual...

Page 2: ...e law to copy the software on any medium except as specifically allowed in the agreement RESTRICTED RIGHTS LEGEND Use duplication or disclosure by the Government is subject to restrictions set forth i...

Page 3: ...ple Stations to Multiple PLCs 3 3 PLC Modules 3 4 Operator Station Connection to ControlNet using the ControlNet Interface Module 3 4 Wiring Guidelines 3 4 Chapter 4 Memory Addressing and Communicatio...

Page 4: ...ii PanelMate ControlNet Communication Driver Manual ControlNet Interface Peer Error codes A 2 System Errors A 2 Local Errors A 3 Index I 1...

Page 5: ...Preface I Preface Welcome to Cutler Hammer s PanelMate ControlNet Communication Driver Manual This chapter gives a brief overview of this manual and provides information on Support Services...

Page 6: ...ControlNet module connects to the network the connectivity options how to configure the PLC Name and Port Table in PanelMate software and wiring guidelines Chapter 4 Memory Addressing and Communicatio...

Page 7: ...echnical support A technical support engineer can be paged for emergencies involving plant down situations or safety issues Emergency support calls are automatically routed directly to our answering s...

Page 8: ...form Repair and Upgrade Service VOICE 614 882 3282 ext 7601 FAX 614 882 3414 Our well equipped Customer Service department is ready to assist you with repairs upgrades and spare parts services If a si...

Page 9: ...Chapter 1 Introduction 1 1 Introduction This chapter discusses Driver installation 1...

Page 10: ...OM Caution Before installing the drivers make sure that the PanelMate Configuration software is not already running To install the drivers from the CD ROM select the Install Software option and then I...

Page 11: ...Chapter 2 ControlNet Interface Module 2 1 ControlNet Interface Module This chapter discusses The Hardware Layout Address Settings LED Indicators 2...

Page 12: ...pecific status The bottom set of stacked LED s are used to monitor redundant ControlNet channel status See the table below for a more detailed description of each component Item Description 1 ControlN...

Page 13: ...71 0 1 0 0 0 1 1 1 22 0 0 0 1 0 1 1 0 72 0 1 0 0 1 0 0 0 23 0 0 0 1 0 1 1 1 73 0 1 0 0 1 0 0 1 24 0 0 0 1 1 0 0 0 74 0 1 0 0 1 0 1 0 25 0 0 0 1 1 0 0 1 75 0 1 0 0 1 0 1 1 26 0 0 0 1 1 0 1 0 76 0 1 0 0...

Page 14: ...d Recoverable configuration fault Invalid firmware OEM data or Personality Block Flashing Green No errors Solid Green No errors Amber Configuration mode Channel Status The Channel Status LEDs are the...

Page 15: ...5 Connectors The Channel A and Channel B connectors J2 and J3 respectively on the ControlNet interface card provide redundant coax media connections to ControlNet using standard BNC female connectors...

Page 16: ...2 6 PanelMate ControlNet Communication Driver Manual...

Page 17: ...Chapter 3 Connectivity 3 1 Connectivity This chapter discusses Supported Messaging Network Connection Connectivity Options PLC Modules Wiring Guidelines 3...

Page 18: ...low shows the rear of a PanelMate Power Pro Series unit To connect the operator station to the ControlNet network 1 Install a passive Tee Tee and drop cable are combined connector 1 on the network cab...

Page 19: ...Chapter 3 Connectivity 3 3 Connectivity Options One Operator Station to One PLC Connecting to ControlNet using the ControlNet Interface Card Multiple Stations to Multiple PLCs...

Page 20: ...s N A Stop Bits N A Parity N A Baud Rate N A Electrical N A Name Use a six character name alphanumeric or underscore Port I O Name assigned to the PLC by the user Model Set to match the A B PLC model...

Page 21: ...to the Allen Bradley PLC 5 Using DF1 PCCC Messaging 4 1 Memory Addressing and Communications to the Allen Bradley PLC 5 Using DF1 PCCC Messaging This chapter discusses PCCC Memory Addressing I O Form...

Page 22: ...C Counter Signed 16 F Floating point IEEE single precision floating point N Integer Signed 16 PD PID R Control Signed 16 T Timer Signed 16 For Control Timer and Counter files word 0 is read only and...

Page 23: ...umber is not specified optional 0 15 Decimal for all other files types including Bit type files which specify the element number Note Access to bits directly within a complex structure such as timers...

Page 24: ...er Manual Bit Counter C 15 CUup enable 14 CD down enable 13 DN done 12 OV overflow 11 UN underflow 0 10 INVALID Bit PID EN CT CL PVT DO SWM CA MO PE INI SPOR OLL OLH EWD DVNA DVPA PVLA PVHA SP KP KI K...

Page 25: ...LC 5 Using DF1 PCCC Messaging 4 5 OUT PVH PVL DVP DVN PVDB DVDB MAXI MINI TIE Bit Control R 15 EN enable 14 EUunload enable 13 DN done 12 EMempty 11 ER error 10 UL unload 9 IN inhibit 8 FD found 0 7 I...

Page 26: ...utput Rack delimiter r Assigned rack number 0 3 for PLC 5 12 and PLC 5 15 0 7 for PLC 5 25 g I O group number 0 7 for all PLC 5 models Bit delimiter b Terminal bit number 0 17 for all PLC 5 models Not...

Page 27: ...2 len Length value in element 52 of Control file 53 R111 721 PoS Position value in element 721 of Control file 111 b041 581 Element 581 of Bit file 41 n421 008 Element 8 of Integer file 421 F8 23 Elem...

Page 28: ...4 8 PanelMate ControlNet Communication Driver Manual...

Page 29: ...ng 5 1 Memory Addressing and Communications to the Allen Bradley ControlLogix Using Control Information Protocol CIP Messaging This chapter discusses CIP References ControlNet Messaging ControlLogix A...

Page 30: ...by commas There can be 0 1 2 or 3 dimensions defined in a single reference All dimensions are delimited by the and characters Range of each dimension is limited by 16 bits 0 0xFFFF and define the offs...

Page 31: ...of data is needed for the new page In this case the old connection s is are terminated and new ones established Background reads for alarming trending and message display are established at startup an...

Page 32: ...en communicating to a ControlLogix PLC and then use that tag cross reference file CSV within the PanelMate Power Pro editor To export with the RSLogix 5000 editor select Export Tags from the Tools pul...

Page 33: ...LC Messages The PLC2 3 5 SLC Mapping dialog box lets the user establish the assignment of file number to array tag name Note that this PLC 5 or SLC file assignment is not shown in the exported tag cro...

Page 34: ...n 0 through 15 DINT nn 0 through 31 SINT nn 0 through 7 mmm is an array element in a one dimensional 1 D array mmm 0 to 65535 Alias is an alias or pointer to another tag An alias can be configured as...

Page 35: ...ruder5_Temp CTL PID Controller1 POS CONTROL message31 REQ_LEN MESSAGE Main_program Counter pre COUNTER within a Program tag First_Floor Tank 0 0 INT within a Program tag The following are examples of...

Page 36: ...5 8 PanelMate ControlNet Communication Driver Manual...

Page 37: ...Appendix A Error Codes A 1 Error Codes This appendix includes ControlNet specific error messages A...

Page 38: ...or The ControlNet Interface module data exchange interface could not be opened Sys 0 ControlNet Interface open data exchange interface timeout The ControlNet Interface module attempt to open the data...

Page 39: ...1 via ControlNet Interface error parsing reference n10 0 An error was encountered parsing the reference the operation cannot be performed Loc 0 on plc1 via ControlNet Interface unscheduled messaging n...

Page 40: ...A 4 PanelMate ControlNet Communication Driver Manual...

Page 41: ...Local Errors A 3 System Errors A 2 ControlNet Interface Status 2 3 ControlNet Messaging 5 3 Correspondence Address P IV D Driver Installation 1 2 E Emergency Technical Support P III H Hardware Layout...

Page 42: ...I 2 PanelMate Power Pro ControlNet Communication Driver Manual...

Page 43: ...cribed in this document Are the instructions easy to follow Are the examples helpful useful Are there enough examples Is the document organized logically Is it easy to find what you are looking for Ar...

Reviews: