4-2
PanelMate ControlNet Communication Driver Manual
PCCC Memory Addressing
General Format
The Allen-Bradley PLC-5 uses decimal word addresses. The Operator Station default format is S16. The
following word and bit addressing descriptions apply to the PLC-5 Command Set.
[xf:e.s/b] -
(/b is an optional field.)
x
File Type
B
Bit (Signed 16)
BT
Block Transfer
C
Counter
*
(Signed 16)
F
Floating point (IEEE single precision floating point)
N
Integer (Signed 16)
PD
PID
R
Control
*
(Signed 16)
T
Timer* (Signed 16)
*
For Control, Timer, and Counter files; word 0 is read only, and words 1 and 2
are read/write.
F
File Number
0-2
Reserved
3
Bit
4
Timer
5
Counter
6
Control
7
Integer
8
Floating Point
9-999
Additional File Storage
:
Element Delimiter
E
Element Number (0 to 999, decimal)
.
Subelement Delimiter
S
Subelement mnemonic (used with
C
ounter,
T
imer, and Cont
r
ol files).
T
imer (T):
PRE:
Preset Value (word 1)
ACC:
Accumulated Value (word 2)