![Custom Equipment HY-BRID LIFTS HB-P3.6 Maintenance & Troubleshooting Manual Download Page 12](http://html1.mh-extra.com/html/custom-equipment/hy-brid-lifts-hb-p3-6/hy-brid-lifts-hb-p3-6_maintenance-and-troubleshooting-manual_2700897012.webp)
BY CUSTOM EQUIPMENT LLC
BY CUSTOM EQUIPMENT LLC
22
23
MAINTENANCE & TROUBLESHOOTING
HB-P3.6
SUPO-726
REV A
MAINTENANCE & TROUBLESHOOTING
HB-P3.6
SUPO-726
REV A
2
1
NO
ENABLE
2
1 NC
E-STOP
2
1 NO
ELEV.
2
1 NO
LWR
TDR
5
4
3
2
1
ARMGUARD TIMER
NO
NC
LIMIT
SWITCH
4
3
2
1
BATTERY GAUGE
BATT+
BATT-
-
+
BATT +
BATT -
PUMP SOL./UP COIL
(OPTIONAL ALL-MOTION ALARM)
See Note 1
NOTES:
1) ULTRASONIC WELD AND HEAT SHRINK
OR BUTT SPLICE AND HEAT SHRINK (2 PLACES)
See Note 1
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
B-SIZE
ORIGINALLY DRAWN BY:
Custom Equipment, Inc.
Richfield, WI 53076
Phone: (262)644-1300
DATE:
WD,HB-P3.6 UPR CTL
SCALE:1:1
DO NOT SCALE DRAWING
THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY TO CUSTOM, EQUIPMENT AND IS LOANED IN EXPECTATION THAT IT WILL BE KEPT CONFIDENTIAL AND USED ONLY FOR THE PURPOSE FOR WHICH IT IS LOANED.
SPEC/MATL: Wiring Diagram
DRAWING #: WD-144-21-010-55
REV
DESCRIPTION OF CHANGE
DATE REV BY
A
INITIAL RELEASE
06/28/2016
DJS
ECO #
2017-3153A
SHEET 1 OF 1
WEIGHT: APPROX. 0.00 LB.
A
5.2 | WIRING DIAGRAM
PART NO. WD-144-21-010-55
SECTION 5 | WIRING DIAGRAMS
SECTION 5 | WIRING DIAGRAMS