4.2 | ELECTRICAL SCHEMATIC
+
-
NC
NO
NC
-
+
M
3
2
1
4
TIME
DELAY
RELAY
5
V
OFF
20 AMP
PUMP
SOLENOID
SOLENOID
OPERATED
UP VALVE
SOLENOID
OPERATED
DOWN VALVE
Down Signal
Armguard Signal
NO
12 VDC
(OPTIONAL LIGHT)
20 AMP
(OPTIONAL ALL-MOTION ALARM)
REV.
DESCRIPTION
DATE
BY
A
INITIAL RELEASE
1/24/2014
DJS
B
REV. DISPLAY OF CONNECTIONS TO TIME DELAY RELAY,
ADDED BEACON & MOTION ALARM OPT
5/27/2014
GH
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
B-SIZE
Custom Equipment, Inc.
Richfield, WI 53076
Phone: (262)644-1300
DATE:3/28/2013
PART NO:WS-144-20-001-51
ELECTRICAL SCHEMATIC, HB-P4.5/5.0
SCALE:1:1
WELDING TOLERANCES: .X= .060 .XX= .030 .XXX= .010
MACHINING TOLERANCES: .X= .030 .XX= .015 .XXX= .005
DO NOT SCALE DRAWING
THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY TO CUSTOM, EQUIPMENT AND IS LOANED IN EXPECTATION THAT IT WILL BE KEPT CONFIDENTIAL AND USED ONLY FOR THE PURPOSE FOR WHICH IT IS LOANED.
WS-144-20-001-51
FORMING TOLERANCES: .X= .06 .XX= .020 .XXX= .010