SL100X/SL240X PROTOCOL
Copyright 2012
8-2
FibreXtreme HW Reference for FPDP Cards
Table 8-1 Ordered Set Mapping
Fibre Channel
Ordered Set
ANSI/VITA 17.1
Ordered Set
Description
SOFc1
SOF
Start of Frame:
PIO1 = 0, PIO2 = 0, DIR = 0
SOFi1
SOF
Start of Frame:
PIO1 = 0, PIO2 = 0, DIR = 1
SOFn1
SOF
Start of Frame:
PIO1 = 0, PIO2 = 1, DIR = 0
SOFi2
SOF
Start of Frame:
PIO1 = 0, PIO2 = 1, DIR = 1
SOFn2
SOF
Start of Frame:
PIO1 = 1, PIO2 = 0, DIR = 0
SOFi3
SOF
Start of Frame:
PIO1 = 1, PIO2 = 0, DIR = 1
SOFn3
SOF
Start of Frame:
PIO1 = 1, PIO2 = 1, DIR = 0
SOFf
SOF
Start of Frame:
PIO1 = 1, PIO2 = 1, DIR = 1
EOFt
SEOF
Status EOF:
FIFO Overflow = 0, NRDY = 0
EOFdt
SEOF
Status EOF:
FIFO Overflow = 0, NRDY = 1
EOFa
SEOF
Status EOF:
FIFO Overflow = 1, NRDY = 0
EOFn
SEOF
Status EOF:
FIFO Overflow = 1, NRDY = 1
EOFni
MEOF
Mark EOF:
EOF for a SYNC frame
EOFdti
FEOF
Frame EOF:
EOF for a normal data frame
R_RDY
SWDV
SYNC with DATA Valid:
Says that the next frame will be a
SYNC with DATA frame
NOS
STOP
Tells the remote transmitter to stop
sending data
CLS
GO
Tells the remote transmitter it can
continue to send data
IDLE
IDLE
IDLE character:
Used as a padding word to maintain
receiver synchronization