Curtiss-Wright | Tritex II AC 90, 115 Rev. X PN39892 7/12/22
61
I/O supply connection
Digital Inputs
The Tritex II 90 mm and 115 mm have 8 digital inputs. They have a
common negative side but are optically isolated from other circuits within
the Tritex to allow the I/O Supply to be grounded. Digital Inputs are
sourcing only; they require a positive voltage to turn on. Each input can
be assigned to any of the internal input functions. (See Software Manual)
Input circuit (internal)
Digital Input Specifications
Description
Specification
Input Voltage Range
0 to 30 VDC
On state voltage range
10-30 VDC
Off state voltage range
0-5 VDC
On state current
10 V (min)
24 v (nominal)
30 V (maximum)
2.6 mA
6.6 mA
8.3 mA
Nominal Impedance (24V)
3.6kΩ
Off state current (max)
1.0 mA
Update rate
2 msec (typical)
Summary of Contents for EXLAR Tritex II AC
Page 12: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 11 UL Certificate of Compliance ...
Page 15: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 14 ...
Page 16: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 15 ...
Page 20: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 19 ...
Page 21: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 20 ...
Page 34: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 33 T2M X115 Actuator Dimensions ...
Page 38: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 37 ...
Page 87: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 86 T2IPC xxx Power Cable ...
Page 88: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 87 TTICO xxx Communications Cable ...