Curtiss-Wright | Tritex II AC 90, 115 Rev. X PN39892 7/12/22
56
Control Logic Power Supply
An optional 24 Vdc power supply may be connected to the Control
Logic Power terminals C+ and C- on the power terminal block. It is
typically used to allow the Tritex II controller to remain powered while
main AC power required for sustained motion is removed. This maintains
position information (position feedback is still powered and active) so re-
homing is not required, and keeps communications active to networked
system components. A fuse is necessary unless power supply self-limits
at 3A or less.
Control Logic Power Supply Wiring and Fusing
Volts
Amps
Fuse
Wire
24V dc +/- 10%.
1
2 Amp, if power supply is
not limited at 3A or less
18 AWG
(0.8 mm^2)
300V, 105
⁰
C
Control Logic Power Supply Connections