Curtiss-Wright | Tritex II AC 90, 115 Rev. X PN39892 7/12/22
24
Specifications: Size 115 Linear Actuators
T2M
/X
115
Stator
1 Stack
2 Stack
3 Stack
Lead
RPM @ 240 VAC
3000
2000
1500
0.1
Continuous Force
lbf (N)
2,060 (9,163)
3,224 (14,341)
NA
Peak Force
lbf (N)
4,120 (18,327)
5,400 (24,020)
NA
Max Speed
in/sec (mm/sec)
5.00 (127)
3.33 (84)
NA
T2X - C
a
(Dynamic Load Rating)
lbf (N)
7900 (35141)
NA
T2M - C
a
(Dynamic Load Rating)
lbf (N)
4736 (21067)
NA
0.2
Continuous Force
lbf (N)
1,177 (5,235)
1,843 (8,198)
2,380 (10,586)
Peak Force
lbf (N)
2,354 (10,471)
3,685 (16,392)
4,760 (21,174)
Max Speed
in/sec (mm/sec)
10.00 (254)
6.67 (169)
5.00 (127)
T2X - C
a
(Dynamic Load Rating)
lbf (N)
8300 (36920)
T2M - C
a
(Dynamic Load Rating)
lbf (N)
4890 (21751)
0.5
Continuous Force
lbf (N)
530 (2,358)
829 (3,688)
1,071 (4,764)
Peak Force
lbf (N)
1,059 (4711)
1,658 (7,375)
2,142 (9,528)
Max Speed
in/sec (mm/sec)
25.00 (635)
16.67 (423)
12.50 (317)
T2X - C
a
(Dynamic Load Rating)
lbf (N)
7030 (31271)
T2M - C
a
(Dynamic Load Rating)
lbf (N)
4218 (18763)
0.75
Continuous Force
lbf (N)
353 (1,570)
553 (2,460)
714 (3,176)
Peak Force
lbf (N)
706 (3,140)
1,106 (4,920)
1,428 (6,352)
Max Speed
in/sec (mm/sec)
37.5 (953)
25 (635)
17.75 (450)
T2X - C
a
(Dynamic Load Rating)
lbf (N)
6335 (28179)
T2M - C
a
(Dynamic Load Rating)
lbf (N)
3328 (14804)
Drive Current @ Continuous Force
Amps
8.5
8.5
8.5
Available Stroke Lengths
in (mm)
4 (102), 6 (150), 10 (254), 12 (300), 18 (450)
Inertia (zero stroke)
lb-in-s
2
/ Kg-m
2
0.01132
(0.000012790)
0.01232
(0.00001392)
0.01332
(0.00001505)
Inertia Adder (per inch of stroke)
lb-in-s
2
/in/ Kg-m
2
/in
0.0005640 (0.0000006372)
Approximate Weight
lb (kg)
34 (15.5) for 6 inch stroke, 1 stack. Add 2 (1) per inch of stroke. Add
8 (4) per motor stack. Add 4 (2) for brake.
Operating Temperature Range
*
-
20 to 65˚ C (
-
40˚C available, consult Exlar)
Continuous AC Input Current
**
Amps
8.3
8.3
8.3
*
Ratings based on 25˚C conditions.
** Continuous input current rating is defined by UL and CSA.
*** T2X peak force for 0.1 inch lead is 5400 lbf (24020 N). T2M peak force for 0.1 inch lead limited to 3966 lbf (17,642 N).
Summary of Contents for EXLAR Tritex II AC
Page 12: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 11 UL Certificate of Compliance ...
Page 15: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 14 ...
Page 16: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 15 ...
Page 20: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 19 ...
Page 21: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 20 ...
Page 34: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 33 T2M X115 Actuator Dimensions ...
Page 38: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 37 ...
Page 87: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 86 T2IPC xxx Power Cable ...
Page 88: ...Curtiss Wright Tritex II AC 90 115 Rev X PN39892 7 12 22 87 TTICO xxx Communications Cable ...