2 — INSTALLATION AND WIRING
pg. 7
1212 & 1212P Manual - Sep 2019
WIRING: STANDARD INSTALLATION, 1212P
The wiring diagram presented in Figure 3b shows a typical installation for a pallet truck application.
This installation is shown with a Curtis electronic throttle. The inhibit input can be wired into
the circuit in various ways; in the standard installation shown here it serves as an interlock (see
pin J1-6), and is B+ inactive (Inhibit Type parameter set to 4).
The J2 connector can be used interchangeably for the programmer or for the charge inhibit.
The polarity of the motor
M1
and
M2
connections will affect the operation of the emergency reverse
feature. The forward and reverse switches and the
M1
and
M2
connections must be configured so
that the vehicle drives away from the operator when the emergency reverse button is pressed.
CAUTION
Figure 3b
Standard Wiring Configuration, Curtis 1212P Controller.
INTERLOCK
KEYSWITCH CONTROL
FUSE
M2
M1
INTERLOCK SW
(Inhibit Type = 4)
J1-8
J3-1
B-
B+
POWER
FUSE
BATTERY
Programmer
1212P Controller
MODE (M1,M2)
J1-4
J1-2
J1-13
J1-1
J1-6
J2-4
J2-3
J2-2
J2-1
B+
I/O GND
Tx
Rx
MOTOR
CURTIS
ET-19XX
J1-5
KSI
EMERGENCY
STOP
MODE SW
STATUS LED
NEUTRAL INPUT
EMERGENCY
REVERSE
EM REV SW
J1-14
PUMP CONTACTOR
COIL
LIFT LOCKOUT
OUTPUT
I/O GND
POT WIPER
J1-3
J1-11
BDI
BDI(0-5V)
J3-2
BRAKE +
BRAKE -
EM BRAKE
LIFT LOCKOUT
INPUT
J1-9
PIN3
B+
B-
CHARGE INHIBIT
J2-3
CHARGER
SOCKET
J1-12
J1-10
POT HIGH
J1-7
B+
POT LOW
HORN
KSI
GND
0.5V-4.5V
Neutral
LIFT SW
HORN
SW
EMERGENCY
STOP
STATUS LED
R
(Throttle Type = 5)
Must match the parameter