8
N:
R - S - T...L:
B
AC 3 N400
IN
OUT
IN
OUT
AC 230
AC 3 208
N
N
N
N
N
N
R
S
T
C
L
N
N
N
R
S
T
AC 3 230
IN
OUT
N
N
N
R
S
T
N
N
N
R
S
T
N
N
N
L
L
L
L
L
IN
OUT
L1
L2
L3
L1
L2
L3
ECO
ECO
A
A
Fig.8.
Electrical connection
Fig.8.
The electrical connection must be carried out
exclusively
by qualified personnel after reading the
safety warnings at the beginning of the manual.
Before installing the appliance,
check that systems
comply with the regulations in force
in the country
where it is going to be used and
with the specifications
indicated on the appliance rating plate
on the RH side of
the oven.
The appliance is supplied without either power cable or plug:
they must both be fitted by qualified personnel. The cable
must be only
of the type stated
and the plug fitted to it must
be suitable for the consumption and connection of the oven to
the electrical mains.
If the oven has a twin chamber, the power cables to be
connected are two as the connecting plugs.
Electrical data
Oven
type
Supply
V
Power
kW
Cable
type
Client’s
panel prot.
nxA
435
Single phase 230V
5,8
H07RN-F 3G4
2x32
three-phase 400V
H07RN-F 5G1
4x16
three-phase 30V
H07RN-F 4G1,5
3x16
three-phase 208V
15/4 SOOW CABLE
3x16
635
three-phase 400V
8,4
H07RN-F 5G1,5
4x16
three-phase 230V
H07RN-F 4G2,5
3x25
three-phase 208V
13/4 SOOW CABLE
3x25
635L
three-phase 400V
8,6
H07RN-F 5G1,5
4x16
three-phase 230V
H07RN-F 4G2,5
3x25
three-phase 208V
13/4 SOOW CABLE
3x25
935
three-phase 400V
12,6
H07RN-F 5G2,5
4x20
three-phase 230V
H07RN-F 4G4
3x32
three-phase 208V
9/4 SOOW CABLE
3x40
Installation
earth
neutral
phases
Summary of Contents for Michelangelo ML435
Page 1: ...Michelangelo OVEN Installation manual ...
Page 2: ...2 ...