background image

Ed. 0219 -  70702521 REV00     Caravaggio - Installation

5

ECO

ECO

ECO

ECO

H

2

O

min.

500 mm

in. 19,7

)

Max 35°C

Max 70%

Min 5°C

Max 104°F

Min 41°C

ECO

ECO

Fig.1. 

Fig.2. 

Fig.3. 

Transport

 

Fig.1.

Fitted with personal protection equipment, transport the 
appliance to the installation location. 
Use suitable equipment, capable of dealing with its weight: 
persons not involved with the appliance installation may not pass 
through or stand in the work area during the appliance assembly.
During the transport, pay particular attention to passing 
through openings and/or doors.

Preliminary operations

 

Fig.2.

Carefully remove the protective film.
If any glue residue is left on the surfaces, remove it with soapy 
water but without any corrosive or abrasive products or sharp 
or pointed instruments.

Check that all the parts making up the oven are in good 
condition and without any faults or breakages, if that is 
not the case, contact the Manufacturer for the 

procedures to follow.

Positioning

 

Fig.3.

Install the appliance in a room:
•   dedicated and suitable to the cooking of food;
•  having adequate air ventilation;
•   that complies with the current regulations on health and 

safety and systems in your country;

•  protected from the weather;
•  with temperatures b5° to +35°C maximum;
•  having a maximum humidity of 70%.

When choosing the positioning room, take into account 

that the appliance must be 

easy to move

 for any 

extraordinary maintenance: be careful since any 

brickwork after installation (e.g.: wall construction, door 
replacement with narrower ones, renovations, etc.) do not 
hamper movements.

Installation

Summary of Contents for Michelangelo ML435

Page 1: ...Michelangelo OVEN Installation manual ...

Page 2: ...2 ...

Page 3: ...it contains important information regarding product assembly and safety regulations Technical service The Manufacturer can solve any technical problem regarding installation Do not hesitate to contact him in case of doubt CUPPONE 1963 Cuppone F lli S r l Via Sile 36 31057 Silea TV ITALY T 39 0422 361143 F 39 0422 360993 info cuppone com www cuppone com Introduction Introduction 3 Technical service...

Page 4: ...ion Installation or maintenance that fails to comply with the instructions in this manual may cause damage injury or fatal accidents Persons not involved with the appliance installation may not pass through or stand in the work area during appliance assembly The serial plate provides important technical information This is vital in case of a request for maintenance or repair of the equipment pleas...

Page 5: ...water but without any corrosive or abrasive products or sharp or pointed instruments Check that all the parts making up the oven are in good condition and without any faults or breakages if that is not the case contact the Manufacturer for the procedures to follow Positioning Fig 3 Install the appliance in a room dedicated and suitable to the cooking of food having adequate air ventilation that co...

Page 6: ...eir correct assembly and fastening to the oven please refer to the instruction sheet accompanying them Fig 5 Comply rigorously with the following minimum distances of the oven from walls other appliances objects and combustible materials left hand side 50 mm right hand side 500 mm to allow easy access to the electrical system if this is not possible when required the oven shall have to be moved fr...

Page 7: ...gether with the one from the door during the work phases must be conveyed outside in one of the following ways through a hood supplied by the Manufacturer that ensures perfect compatibility with the oven For its correct assembly and fastening to the oven please refer to the instruction sheet accompanying it through an adequate extraction system supplied by the user in this case a draught switch mu...

Page 8: ... personnel The cable must be only of the type stated and the plug fitted to it must be suitable for the consumption and connection of the oven to the electrical mains If the oven has a twin chamber the power cables to be connected are two as the connecting plugs Electrical data Oven type Supply V Power kW Cable type Client s panel prot nxA 435 Single phase 230V 5 8 H07RN F 3G4 2x32 three phase 400...

Page 9: ...be made between the various devices with the terminal marked with the equipotential symbol The cable must have a maximum cross section of 10 mm2 in compliance with IEC EN 60335 2 42 2003 09 and must be yellow green must be grounded to the mains green yellow wire must be connected to a thermal differential switch in compliance with the regulations in force 0 03A A type must be connected to an omnip...

Page 10: ...ICROPROCESSOR KEYBOARD DISPLAY TOUCH C BF09 In 09A 0 12 microF I55 C 20A 1 A1 A2 A2 A1 A3 B1 B2 B3 Θ Installation Abbreviation Description CTRL B Oven control board C Motor start capacitor F Noise filter FU Fuses ID Digital input for remote ignition KM Contactor BF09 MC09 L Cooking chamber lights M1 Board cooling fan motor M Chimney opening motor PW B Power board RA1 2 3 Top resistors RB1 2 3 Bott...

Page 11: ... D ID TC RS485 PW B MICROPROCESSOR KEYBOARD DISPLAY TOUCH TR1 230Vac 12Vac 20VA FU T2 5AL250V Θ Θ Installation Abbreviation Description CTRL B Oven control board C Motor start capacitor F Noise filter FU Fuses ID Digital input for remote ignition KM Contactor BF09 MC09 L Cooking chamber lights M1 Board cooling fan motor M Chimney opening motor PW B Power board RA1 2 3 Top resistors RB1 2 3 Bottom ...

Page 12: ...2 RA A3 TB B1 SB B2 B3 RB COM RS485 GND 12Vcc D D GND D D ID TC RS485 MICROPROCESSOR DISPLAY TOUCH KEYBOARD Θ Θ Abbreviation Description CTRL B Oven control board C Motor start capacitor F Noise filter FU Fuse ULKTK 600V 2A FU1 Fuse ULKTK 600V 0 5A ID Digital input for remote ignition KM Contactor BF26 MC32 L Cooking chamber lights MF Fan M Chimney opening motor PW B Power board RA1 2 3 Top resist...

Page 13: ...ls and fumes that will gradually disappear during the following operating cycles Finish off explaining to the user how to use the appliance in an optimal and safe way and how to carry out ordinary maintenance and cleaning Positioning checks Reference chapter on page IS the installation room adequate and compliant with regulations correct ventilation maximum minimum temperature etc Positioning on p...

Page 14: ...CUPPONE 1963 Cuppone F lli S r l Via Sile 36 31057 Silea TV ITALY T 39 0422 361143 F 39 0422 360993 info cuppone com www cuppone com ...

Reviews: