3.3.2  Cabling

Pic. 5 - Cabling

If installing your own power cord, use only a three prong 

grounded cord with minimum 16 gauge wire.

Referring to Pic. 6:

 

»

To install a power cord, fi rst remove the cover from the elec-

trical connection box on the rear of the humidifi er by un-

screwing the four screws 

V

.  A Phillips head screwdriver is 

needed.

 

»

Unscrew the grey cap at the end of the power cord holder 

P

.  Slide the cap fi rst down the end of the power cord then 

insert power cord through the hole of the power cord holder.  

Do not fully tighten the cap until proper slack and distances 

inside the power box have been set.  

 

»

Carefully remove the electronic board 

M

 from the box by 

gently pulling it directly backwards.  It should slide out from 

the slots 

G

.

 

»

Connect all three wires-phase, neutral, ground- to the fi rst 

three terminals on the circuit board.  Match white to white, 

black to black, and green to green.

 

»

Put the electronic board back into electrical connection box 

by sliding it back carefully into the slots 

G

.

 

»

Close the electrical connection box and reinsert the four 

screws into their proper holes.  Verify enough slack is in the 

box and then tighten down the cap on the power cord holder 

to secure the cord in place and also prevent moisture from 

entering the electrical connection box.

3.4  Hydraulic connections

Pic. 6 - Hydraulic connections

Th e installation of the humidifi er requires 2 water connections—

one to feed the humidifi er (water supply hose) and one for drain-

ing (drain hose).  Both are included with your humidifi er.  

3.4.1  Water Supply Hose

Th e water supply hose has 3/4” diameter fi ttings at both ends.  

Connect the end that is “L” shaped to the male fi tting at the rear 

of the humidifi er.  Tighten fi rmly and plumber’s tape can be used 

to reduce any leaking.  Th e other end should be connected to 

your water supply, which should also have a 3/4” male fi tting.  It 

is possible to use reducers to take the hose diameter down from 

3/4” to 1/4” in order to use 1/4” tubing instead of 3/4”.  

IMPORTANT! Water Quality.  Th e use of water that has 

gone through the process of reverse osmosis (RO) water 

fi ltration is HIGHLY recommended to reduce calcium car-

bonate sediment occurring in the area being humidifi ed, 

as well as helping keeping the humidifi er clean and free 

from sediment blockages.  

3.4.2  Drain Hose

Th e drain hose should be installed by sliding it on to the water 

discharge port of the humidifi er—which is located below the 

water inlet male fi tting.  A longer hose can be used; just make 

sure it has an internal diameter of 3/8”.  

IMPORTANT! –Drain Hose Placement.  Th e drain hose 

must be hung down from the humidifi er’s installed loca-

tion at a very minimum angle of 100 in order to assure 

the water will drain correctly.  Th e hose should hang as 

straight down as possible.  Make certain there are no 

kinks, bottlenecks, or elbows in the hose to prevent water 

from draining out of the hose.  In addition, the end of the 

drain hose should be kept free from blockage and 1) NOT 

placed below the water’s surface in the drain and 2) NOT 

placed in a closed container that will have suffi  cient pres-

sure to keep the water from draining out of the hose (See 

Summary of Contents for mini NEB F3005

Page 1: ...F3005 mini NEB READ AND SAVE THESE INSTRUCTIONS Adiabatic humidifier ...

Page 2: ......

Page 3: ... o ring 13 0080348 Electric motor bracket 14 0080349 Air diffuser 15 0080356 Air filter 16 0080436 Drain elbow 17 0080437 Siphon 18 0080438 Drain pipe 19 0080447 O ring ø12 internal 20 0090154 Breather pipe 21 0090969 Solenoid valve with flow control 22 0090981 Inlet hose 23 0090982 Outlet hose 24 0091115 Basin assembly 25 0091135 Main body assembly 26 0091136 Junction box assembly 27 0091137 Elec...

Page 4: ...allation 8 4 Startup control turn off 9 4 1 Checks 9 4 2 Start up 9 4 3 Turn off 9 5 Maintenance 9 5 1 Introduction 9 5 2 Inspection and cleaning of the water feed solenoid valve 9 5 3 Air filter cleaning 10 5 4 Basic cleaning of the drain 10 5 5 Advanced cleaning to be performed as needed or monthly 10 5 6 Cleaning of the cone and the disk 11 6 Storage 12 6 1 General notes 12 6 2 Checklist to be ...

Page 5: ...ules Before installing the unit OR performing any maintenance or inspection of the unit be sure it is disconnected from the power supply Read all instructions before operating humidifier Keep humidifier free from obstructions to allow unit to function properly The humidifier must be connected to an electrical supply that complies with local regulations It is strongly recom mended to plug the humid...

Page 6: ...t the minimal distance to allow proper air flow and dispersion of humidity Any other positioning or shortened distances may compromise the performance of the humidifier 3 2 1 Minimal distances Pic 3 Positioning A B C D Minimal ft 6 6 1 6 1 6 2 6 Suggested ft 9 8 3 3 4 9 4 9 Tab 4 Minimal distances 3 3 Electrical connections 3 3 1 Electrical wiring diagram Pic 4 F3005 Wiring diagram 1 Humidifier mo...

Page 7: ...nd one for drain ing drain hose Both are included with your humidifier 3 4 1 Water Supply Hose The water supply hose has 3 4 diameter fittings at both ends Connect the end that is L shaped to the male fitting at the rear of the humidifier Tighten firmly and plumber s tape can be used to reduce any leaking The other end should be connected to your water supply which should also have a 3 4 male fitt...

Page 8: ...allation is confirmed to be solid and secure tighten four screws attaching bracket to rear of humidifier IMPORTANT Observe minimal distances in Par 3 2 when wall mounting the Cuoghi Mini NEB Make sure bracket is completely horizontal before drilling holes Be certain the wall is able to sustain the weight of the humidifier 10 9 lbs If drilling through drywall it is highly recommended to screw into ...

Page 9: ...er the humidistat to OPEN the main switch at the H H terminals The humidifier will slow down and the water inside the unit will fall back down to the water basin and trigger the siphon where it will be discharged through the drain hose IMPORTANT After shutting down the humidifier wait at least 30 seconds to allow the waste water to be completely discharged otherwise the siphon may not completely c...

Page 10: ... filter Clean the air filter media first by vacuuming then by rinsing upside down with water and a household detergent Let the air filter media dry naturally do not ring or squeeze it Reassemble all of the pieces carefully checking that the air filter media is correctly positioned in the plastic assembly and then re tighten down with screws Air filter media must be completely dry before reinstalla...

Page 11: ...bs release and the cone eases out The black gasket Or of the cone remains on the bottom of the disk gently pry it out and check that it is not damaged If it s compromised it must be replaced Remove the screw S and the disk D Clean the cone and the disk remove any dirt that can reduce or stop the passage of the water Pic 17 The cone and its gasket To assemble the cone follow carefully the following...

Page 12: ...CAUSES SOLUTIONS The power supply is interrupted Check the electrical connections start ing from the electrical control box to the internal box of the humidifier The start capacitor is burned Substitute the capacitor with a new one 7 2 Air comes out from the air outlet but not nebulized water POSSIBLE CAUSES SOLUTIONS Water does not arrive to the basin Check that the water supply tap is opened Che...

Page 13: ......

Page 14: ...Notes ...

Page 15: ...Notes ...

Page 16: ...CUOGHI LLC 135 Brandywine blvd suite A Fayetteville GA 30214 info cuoghillc com www cuoghillc com ...

Reviews: