Pic. 11 - Solenoid valve

If cleaning becomes too frequent, it is advisable to install a car-

tridge fi lter on the water supply line (see: paragraph 3.4 - Hy-

draulic connections)

WARNING: do NOT run the humidifi er without the water 

fi lter C.

5.3  Air fi lter cleaning

Pic. 12 - Air fi lter disassemble

Th e air fi lter will need to be cleaned periodically as dirt and dust 

will accumulate in the fi lter and reduce the incoming air fl ow 

which will lower the overall effi  ciency of the humidifi er.  How 

often the air fi lter needs to be cleaned depends on the air quality 

and the environment in which the humidifi er operates.  
To clean the air fi lter:

 

»

Disassemble the fi lter assembly by unscrewing the two screws 

V

” that keep the plastic screen “

R

” in place.

 

»

Remove plastic assembly and mesh air fi lter.

 

»

Clean the air fi lter media fi rst by vacuuming, then by rinsing 

upside down with water and a household detergent.  

 

»

Let the air fi lter media dry naturally; do not ring or squeeze 

it.  Reassemble all of the pieces; carefully checking that the 

air fi lter media is correctly positioned in the plastic assembly 

and then re-tighten down with screws.  

 

»

Air fi lter media must be completely dry before reinstallation 

and starting the humidifi er.  

IMPORTANT!  Never run the humidifi er without the air 

fi lter assembly.

5.4  Basic cleaning of the drain

Pic. 13 - Parts to be cleaned

 

»

Remove the grid and the air fi lter.

 

»

Remove and clean the plastic elbows 

E1

 and 

E2

, the pipes 

P1

 and 

P2

.

 

»

Reassemble all the parts and remember to place the o-ring 

Or

 in the plastic elbow 

E2

.

5.5  Advanced cleaning (to be performed as 

needed or monthly)

 

»

Remove the three screws 

S1

 that fi x the basin to the main 

body.

 

»

Remove the two screws 

S2

 that fi x the electric box to the 

main body.

 

»

Remove together the basin and the electric box from the 

main body.

Summary of Contents for mini NEB F3005

Page 1: ...F3005 mini NEB READ AND SAVE THESE INSTRUCTIONS Adiabatic humidifier ...

Page 2: ......

Page 3: ... o ring 13 0080348 Electric motor bracket 14 0080349 Air diffuser 15 0080356 Air filter 16 0080436 Drain elbow 17 0080437 Siphon 18 0080438 Drain pipe 19 0080447 O ring ø12 internal 20 0090154 Breather pipe 21 0090969 Solenoid valve with flow control 22 0090981 Inlet hose 23 0090982 Outlet hose 24 0091115 Basin assembly 25 0091135 Main body assembly 26 0091136 Junction box assembly 27 0091137 Elec...

Page 4: ...allation 8 4 Startup control turn off 9 4 1 Checks 9 4 2 Start up 9 4 3 Turn off 9 5 Maintenance 9 5 1 Introduction 9 5 2 Inspection and cleaning of the water feed solenoid valve 9 5 3 Air filter cleaning 10 5 4 Basic cleaning of the drain 10 5 5 Advanced cleaning to be performed as needed or monthly 10 5 6 Cleaning of the cone and the disk 11 6 Storage 12 6 1 General notes 12 6 2 Checklist to be ...

Page 5: ...ules Before installing the unit OR performing any maintenance or inspection of the unit be sure it is disconnected from the power supply Read all instructions before operating humidifier Keep humidifier free from obstructions to allow unit to function properly The humidifier must be connected to an electrical supply that complies with local regulations It is strongly recom mended to plug the humid...

Page 6: ...t the minimal distance to allow proper air flow and dispersion of humidity Any other positioning or shortened distances may compromise the performance of the humidifier 3 2 1 Minimal distances Pic 3 Positioning A B C D Minimal ft 6 6 1 6 1 6 2 6 Suggested ft 9 8 3 3 4 9 4 9 Tab 4 Minimal distances 3 3 Electrical connections 3 3 1 Electrical wiring diagram Pic 4 F3005 Wiring diagram 1 Humidifier mo...

Page 7: ...nd one for drain ing drain hose Both are included with your humidifier 3 4 1 Water Supply Hose The water supply hose has 3 4 diameter fittings at both ends Connect the end that is L shaped to the male fitting at the rear of the humidifier Tighten firmly and plumber s tape can be used to reduce any leaking The other end should be connected to your water supply which should also have a 3 4 male fitt...

Page 8: ...allation is confirmed to be solid and secure tighten four screws attaching bracket to rear of humidifier IMPORTANT Observe minimal distances in Par 3 2 when wall mounting the Cuoghi Mini NEB Make sure bracket is completely horizontal before drilling holes Be certain the wall is able to sustain the weight of the humidifier 10 9 lbs If drilling through drywall it is highly recommended to screw into ...

Page 9: ...er the humidistat to OPEN the main switch at the H H terminals The humidifier will slow down and the water inside the unit will fall back down to the water basin and trigger the siphon where it will be discharged through the drain hose IMPORTANT After shutting down the humidifier wait at least 30 seconds to allow the waste water to be completely discharged otherwise the siphon may not completely c...

Page 10: ... filter Clean the air filter media first by vacuuming then by rinsing upside down with water and a household detergent Let the air filter media dry naturally do not ring or squeeze it Reassemble all of the pieces carefully checking that the air filter media is correctly positioned in the plastic assembly and then re tighten down with screws Air filter media must be completely dry before reinstalla...

Page 11: ...bs release and the cone eases out The black gasket Or of the cone remains on the bottom of the disk gently pry it out and check that it is not damaged If it s compromised it must be replaced Remove the screw S and the disk D Clean the cone and the disk remove any dirt that can reduce or stop the passage of the water Pic 17 The cone and its gasket To assemble the cone follow carefully the following...

Page 12: ...CAUSES SOLUTIONS The power supply is interrupted Check the electrical connections start ing from the electrical control box to the internal box of the humidifier The start capacitor is burned Substitute the capacitor with a new one 7 2 Air comes out from the air outlet but not nebulized water POSSIBLE CAUSES SOLUTIONS Water does not arrive to the basin Check that the water supply tap is opened Che...