Part No. 4801-3030 Rev. 1-15
Page
5
of
22
Super Saver XL-240 Heater
3.
Maintenance and Warranty
MAINTENANCE
1.
The appliance area should be kept clear & free from combustible materials, gasoline and other
flammable vapors, and liquids.
2
The flow of combustion and ventilation air must not be obstructed.
3.
Your Super Saver XL Heater should be inspected before each use, and at least annually by a qualified
service person.
4.
The hose should be visually inspected prior to each use of the heater. If it is evident there is excessive
abrasion or wear or the hose is cut, it must be replaced prior to the heater being put into operation.
The replacement hose assembly shall be that specified by the manufacturer. (See parts list).
5.
Inspect heater and gas connections periodically for gas leaks with an approved gas leak testing
solution (soap and water work well).
6.
Keep heater clean at all times.
A.
Open doors and blow out dust with high pressure air hose. Be sure interior of burner
and flared end are kept clean.
B.
Burner orifice and direct spark ignition assembly must be kept clean and free of
carbon build-up.
C.
Check blower wheel regularly for dust accumulation and clean periodically for
maximum airflow.
D.
Thermostat coils must be kept clean to assure proper temperature control.
E.
Heater must be cool before wash down. Do not operate heater for one hour following
wash-down.
DISCLAIMER
This appliance rating is based on the use of ANSI LC-2 test gases including LP (2500 BTU/ft
3
,
93.15 MJ/m
3
) and natural gas (1075 BTU/ft
3
, 40 MJ/m
3
). Cumberland makes no guarantees
regarding the proper operation of this appliance when these conditions are not met.