5.2. Installing Dual-Flare Duct
Fold Dual-Flare duct to shape as shown in Figure 2. Install Dual-Flare duct to heater exhaust (Figure 2) as
shown with sheet metal screws provided. This provides a multi-directional heat flow that may be set by
bending flaps.
5.3. Connecting The Gas Supply
For gas connection (Figure 3) attach regulator to the Hi-Pressure Line (A) at outside of building. Connect
flexible hose (B) to low pressure end of regulator with special brass coupling. See Section 2 for Universal LP
and natural gas requirements.
The installer must attach an installer-supplied flexible gas hose to the factory-supplied G ¾ male 60 degree
BSPP flare nut adaptor connected to the heater ball valve. Installation must be in accordance to AS/NZS
5601.1.