V1.0
1/6 HP Portable Submersible Sump Pump
8887119
Visit www.princessauto.com for more information
5
17. Do not expose the pump to freezing temperatures. Freezing could
cause severe damage.
18. Do not insert fingers or any object into the pump or motor openings.
19. The pump normally runs hot. To avoid burns when servicing the pump,
allow it to cool after shutdown before handling it.
20. Always check the pump before each operation. A damaged pump must
not be used. Replace the pump.
ELECTRICAL SAFETY
WARNING! Hazardous voltage can shock, burn or kill. When installing,
operating or servicing this pump, follow the safety instructions listed below.
1.
Before installing this product, have the electrical circuit checked by an
electrician to ensure proper grounding.
2. Connect this product to a grounded circuit equipped with a Ground
Fault Circuit Interrupter (GFCI) device.
3.
Do not install the pump in any location classified as hazardous by the
National Electrical Code, ANSI / NFPA 80-1984 or the Canadian Electrical
Code.
4.
Do not allow the plug on the end of the electrical cord to be submerged.
5.
Do not use extension cords. They are a fire hazard and can reduce the
voltage sufficiently to prevent pumping and / or damage the motor.
6.
Do not handle or service the pump while it is connected to the power
supply.
7.
The supply voltage must be within 10% of the nameplate voltage.
Incorrect voltage can cause fire or seriously damage the motor and
voids the warranty. If in doubt, contact a licensed electrician.
8. Meet all national electrical code and local codes for all wiring.
9. Do not handle a pump or pump motor with wet hands, or when
standing on a wet or damp surface or in water.
10. Protect yourself against electric shocks when working on electrical
equipment. Avoid body contact with grounded surfaces. There is an
increased chance of electrical shock if your body is grounded.
11. The fuse must be a residual current circuit-breaker with a measured
residual current of no more than 30 mA.
12. If the device is not in use, make sure that the plug is removed from the
power source.