Things to Check Before You Call For Service
13
01040684 A 06/21
If you unexpectedly experience iron staining or rusty water, make these simple checks before calling your Culligan deal er�
One of the following conditions may be the reason for your change in water quality�
Important
If any of the following conditions is found, the water filter should be man u al ly reconditioned after you have corrected the problem�
Power Supply
Check your power supply cord� Is it plugged fully into the electric outlet? Be certain that the outlet is not controlled by a wall
switch which has been turned off� If power was interrupted it may be necessary to reset the control to correct time of day�
Tripped Circuit Breaker
An extended power disruption or daylight savings time could alter the time of reconditioning due to incorrect time of day
displayed on your Culligan unit� Reset "Time of Day" following the step by step instructions printed on the cover of the unit
below the display or in
"Table 1� Setting Time of Day" on page 10
� An optional battery back-up may be added to maintain
time of day during prolonged power outages� Please contact your local Culligan dealer for further information�
Power Failure
Any interruption in your power supply or time changes - such as daylight savings - will disrupt your filter’s reconditioning
schedule by causing the timer to run off-schedule� Reset timer to proper time of day�
Bypass Valves
Check to see if they are in the proper position� Cul-Flo-Valv® Bypass, if used, should be in the “Service” (handle stem
screwed out) position� If hand valves are used, see that inlet and outlet valve are opened and that the bypass valve is closed�
No Water
If you aren’t getting any water flow at all, make sure your water supply is work ing� Open a tap ahead of the filter (outside tap)
to see if you have any water pressure� If you have water pressure, check the bypass valve� If it is in the Service position, put
it into the bypass and call your Culligan dealer for service�
Increased Usage
Guests, family additions, new water-using appliances, etc�, all will result in more water usage and will require more
capacity from your filter� You can re pro gram your reconditioning schedule by following the directions
� Call your
Culligan dealer for advice and save a service call�
Outdoor Electrical and Power Supply
• The Installer should set the Media tank on a solid, level surface near
plumbing, drain, and electrical connections� The Media tank and
plumbing should be secured so the system can’t be knocked over�
• The customer should provide a GFCI electrical outlet suitable for
outdoor use that is NOT controlled by a switch that can be turned
off accidentally�
• For outdoor installation, only use an outdoor rated power supply�
• Power supply MUST be mounted on the wall at least 1 foot above
ground level�
• Properly ground to conform with all governing codes
and ordinances�
• Observe all state and local electrical codes�
• P/N 01041744 plug-in 20-foot power supply is included with
Outdoor systems and is rated for Outdoor installations. It is to
be mounted within 2-ft. of the outdoor receptacle. It MUST be
mounted at least 1-ft above ground level
• P/N 01040230 is an optional 20-foot extension cable rated for
outdoor installations (not included)�
• For Outdoor use with a UL Listed Class 2 Direct Plug-in
Power Unit only�
WARNING!
Use only Outdoor Power supplies for Outdoor installations.
DO NOT use Indoor Power Supplies for Outdoor system installations.