background image

on pressures above the UPC for extended periods of time can increase the service frequency and failure of replacement 

parts� On a private water system, make sure the minimum pressure (when the pump starts) is greater than 20 psi (140 kPa)�

CAUTION! 

 

The use of a pressure reducing valve may limit the flow of water in the household.

Temperature

 - Do not install the unit where it might freeze, or next to a water heater or furnace or in direct sunlight� 

Outdoor installations require the use of the Outdoor Iron-OX5 filter system� Indoor systems installed outdoors will void the 

warranty and UL certification�

Reconditioning Cycle

There are several conditions that will cause the control to initiate a reconditioning cycle� The “REG” enunciator will 

light when the control has signaled for a reconditioning cycle� The “REG” enunciator will flash while the control is in a 

reconditioning cycle� The following are conditions that will call for reconditioning, assuming “dip 2” has been set to “DEL”:

1�  When the time clock has counted past the set number of days�

2�  At the preset time, after the “REG” button is depressed once� “REG” will light�

3�  Immediately, when the “REG” button is depressed for three seconds� “REG” will light and blink�

4�  Immediately, if power to the unit has been off for more than 3 hours and time of day has been returned�

5�  When the flow meter has recorded the passage of a predetermined number of gallons�

If “Dip Switch 2” is set to “Immediate”, the unit will begin a reconditioning cycle immediately for instances 2 and 4� With 

“Dip Switch 2” set to “Delayed”, the reconditioning cycle will not begin until the preset reconditioning time�

NOTE! 

If set to immediate mode as timeclock, the unit will initiate the reconditioning cycle at 12:00 AM. In the 

delay mode, “REG” indicator will light at 12:00 AM and reconditioning cycle will occur at programmed 

delayed time.

Display Lockout

The Culligan Select Plus

®

 Series control is equipped with a feature which will allow you to protect the programmed 

settings from tampering by unauthorized individuals� When the lockout feature is activated, the only parameters which can 

be adjusted are the Time-of-Day and the Time of Reconditioning Cycle� Refer to the “Setting of the Microprocessor” for 

activating this feature�

Power Loss

The AccuSoft

®

 circuit board is equipped with a Hi-Cap Capacitor and EEPROM memory chip� The capacitor is capable 

of maintaining the time, for at least two days, in the event of a power outage� The EEPROM ensures that the individual 

programming parameters of the filter are retained�
If the power outage lasts long enough to drain the Hi-Cap Capacitor, the control will flash “12:00 PM” when power 

is returned to the control� The unit will continue to keep time from the moment power is restored, and will initiate a 

full reconditioning cycle at the preset reconditioning time� The time of day will need to be reset in order to return the 

reconditioning cycle to its preset time�
Installing the optional battery back-up onto the circuit board will ensure the correct time of day is retained in the event of 

power outages lasting longer than two days�

Service

The Culligan Select Plus

®

 water filter is equipped with a self diagnostic program to insure optimal operation of your water 

filter� Should service become necessary, a phone icon will appear in the display� If this condition occurs, call your local 

Culligan Dealer for assistance� The phone icon and error code will be the only items displayed when service is required on 

the control�

9

 01040684  A  06/21

Summary of Contents for Aquasential Select Plus 10 Iron-OX5

Page 1: ...Aquasential Select Plus Iron OX5 Sulfur OX3 Filters Models from 2021 DCO 200382 06 30 21 CAT 01040684 Rev A 2021 Culligan International Company ...

Page 2: ... Analytical Laboratory is certified to perform coliform and E coli testing We strive to provide our customers with the testing they need at the lowest possible cost with the quickest turn around time STANDARD WATER TESTING For sizing systems and general chemical water characteristics WELL WATER TESTING Basic Realtor Drilling Surveilance Expanded Gold SPECIAL WATER TESTING Hemodialysis Scale Resin ...

Page 3: ...er 5 Thank You 6 Specifications 7 Application Operation 8 Menu Navigation 10 Care Cleaning 11 When How to Bypass Your System 12 Things to Check Before You Call For Service 13 Performance Data Sheet 14 Records Data 16 Culligan Limited Warranty 17 3 01040684 A 06 21 ...

Page 4: ...E Note is used to emphasize installation operation or maintenance information which is important but does not present any hazard Caution CAUTION Caution is used when failure to follow directions could result in damage to equipment or property Warning WARNING Warning is used to indicate a hazard which could cause injury or death if ignored The CAUTION and WARNING paragraphs are not meant to cover a...

Page 5: ...ON If the power cord from the power supply to the unit looks or becomes damaged the cord and power supply should be replaced by a Culligan Service Agent or similarly qualified person in order to avoid a hazard CAUTION To reduce the risk of fire use only No 26 AWG or larger telecommunications line cord NOTE This system is not intended for use with water that is microbiologically unsafe or of unknow...

Page 6: ...allation operating and maintenance procedures A troubleshooting section provides a guide for quick and accurate problem solving Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system CAUTION This system is to be supplied with cold water only Installation or maintenance done on this system by an untrained service person ...

Page 7: ...psi 4 gpm 2 9 psi Maximum 6 gpm 9 psi 6 gpm 9 psi Operating Pressure 20 60 psi 20 60 psi Operating Temperature 33 120 F 1 48 C 33 120 F 1 48 C Electrical Requirements 24V 60Hz 24V 60Hz Power Consumption Continuous Maximum 3 Watts 10 Watts 3 Watts 10 Watts Drain Flow 5 5 gpm 5 5 gpm Reconditioning Time Backwash 15 minutes 15 minutes Air Draw 40 minutes 40 minutes Fast Rinse 5 minutes 5 minutes Capa...

Page 8: ... in sufficient volume for the required airhead During the Rinse cycle the air charge is compressed and stored within the filter tank and the filter media is rinsed prior to the system returning to the service cycle Hydrogen Sulfide Hydrogen Sulfide usually occurs naturally in well water as a dissolved gas It is typically the result of organic decomposition It has a characteristic rotten egg odor a...

Page 9: ...ode as timeclock the unit will initiate the reconditioning cycle at 12 00 AM In the delay mode REG indicator will light at 12 00 AM and reconditioning cycle will occur at programmed delayed time Display Lockout The Culligan Select Plus Series control is equipped with a feature which will allow you to protect the programmed settings from tampering by unauthorized individuals When the lockout featur...

Page 10: ...g cycle The REG annunciator will light when the control has signaled for a reconditioning The REG annunciator will flash while the control is in reconditioning The following are conditions that will call for reconditioning 1 When the flow meter has recorded the passage of a predetermined number of gallons 2 At the preset time when the number of days without a reconditioning is equal to the Timeclo...

Page 11: ...Important Culligan water systems are sold for use with potable water only If at any time the water becomes contaminated such as during a boil water situation the operation of the water system should be discontinued until it is verified that the water is again potable To do this turn the knob on the bypass valve to the bypass position Then call your Culligan dealer to have your system sanitized bef...

Page 12: ...e In the back of Culligan water filter is a Cul Flo Valv Bypass valve To bypass the unit turn the blue knob clockwise To return to filtered water service turn the blue knob counter clockwise Bypassed To BYPASS turn the blue knob clockwise see directional arrow on end of knob until the knob stops as shown in Figure 1 DO NOT OVERTIGHTEN Figure 1 Bypass valve Filtered Water To return to SERVICE turn ...

Page 13: ...t the bypass valve is closed No Water If you aren t getting any water flow at all make sure your water supply is work ing Open a tap ahead of the filter outside tap to see if you have any water pressure If you have water pressure check the bypass valve If it is in the Service position put it into the bypass and call your Culligan dealer for service Increased Usage Guests family additions new water...

Page 14: ... NSF ANSI Standard 42 for the effective reduction of iron up to 500 gallons as verified and substantiated by test data The Culligan Outdoor Select Plus Iron OX5 filter system has been tested and certified by WQA against NSF ANSI Standard 372 and NSF ANSI standard 42 for the effective reduction of iron up to 500 gallons as verified and substantiated by test data The Culligan Select Plus Iron OX5 fi...

Page 15: ...en sulfide up to 500 gallons as verified and substantiated by test data The Culligan Outdoor Select Plus Sulfur OX3 water filter system has been tested and certified by WQA against NSF ANSI Standard 372 and Standard NSF ANSI 42 for the effective reduction of hydrogen sulfide up to 500 gallons as verified and substantiated by test data The Culligan Select Plus Sulfur OX3 water filter system has bee...

Page 16: ...ation Annual Bi Annual Day Override Interval Owner Maintenance Replace Cartridge Filter s Water Analysis Hardness ____________________ grains gallon TotalDissolvedSolids TDS______________________mg l pH level acidity _____________________ S U Alkalinity_______________________________grains gallon Iron _______________________________ mg l Manganese__________________________________mg l Chlorine ___...

Page 17: ...disclaims all implied warranties including without limitation warranties of merchantability and fitness for particular purpose to the extent required by law any such implied warranties are limited in duration to the one year period specified above for the entire conditioner As a manufacturer we do not know the characteristics of your water supply or the purpose for which you are purchasing a water...