You have just purchased one of the finest reverse osmosis water treatment systems made� As an expression of our confidence in 

Culligan International Company products, your water treatment system is warranted to the orig i nal end-user, when in stalled in ac-

cor dance with Culligan specifications, against defects in material and work man ship from the date of original installation, as follows:

For the LIFETIME of the system

• Molded system manifold

For a period of TEN YEARS

• Faucet (Standard RO) 

• RO tank (Standard & Smart RO) 

• All other parts of the RO system (Standard & Smart RO)

For a period of FIVE YEARS

• Faucet w/display (Smart RO) 

• Rechargeable battery pack (Smart RO) 

• PCBs & associated LEDs & displays (Smart RO)

For a period of ONE YEAR

• Filters & Membranes (Standard & Smart RO)

If a part described above is found defective within the specified period, you should notify your independently operated Culligan 

dealer and arrange a time during normal business hours for the dealer to in spect the water treatment unit on your premises� Any 

part found defective within the terms of this warranty will be re paired or replaced by the dealer� You pay only freight from our 

factory and local dealer charges�
We are not responsible for damage caused by accident, fire, flood, freezing, Act of God, misuse, misapplication, neglect, 

oxidizing agents (such as chlorine, ozone, chloramines and other related components), alteration, installation or operation con-

trary to our written instructions, or by the use of accessories or components which do not meet Culligan specifications, is not 

covered by this warranty� Refer to the specifications section in the Installation and Operating manual for application parameters�
Our product performance specifications are furnished with each water treatment system� To the extent permitted by law, culligan 

disclaims all implied warranties, including without limitation warranties of merchantability and fitness for particular purpose; to 

the extent required by law, any such implied warranties are limited in duration to the one-year period specified above for the 

entire conditioner� As a manufacturer, we do not know the characteristics of your water supply or the purpose for which you 

are purchasing a water treatment system� The quality of water supplies may vary sea son al ly or over a period of time, and your 

water usage rate may vary as well� Water characteristics can also differ considerably if your water treatment system is moved 

to a new location� For these reasons, we as sume no liability for the determination of the proper equipment necessary to meet 

your requirements, and we do not authorize others to assume such ob ligations for us� Further, we assume no liability and 

extend no warranties, express or implied, for the use of this product with a non-potable water source� Warranty is void if system 

is installed outside a building without being rated for outdoor use� Our obligations under this warranty are limited to the repair 

or replacement of the failed parts of the water treatment system, and we as sume no liability whatsoever for direct, indirect, 

incidental, consequential, special, general, or other damages� 
The product and major parts are not covered by this warranty under any of the following circumstances: aging, bumping, 

scratching, etc� of the product during normal maintenance and use, the warranty period has expired, proof of purchase in the 

form of customer receipt or invoice cannot be found, any damage caused by installation or disassembly of the product by a 

non-authorized professional, the consumer has made a warranty claim but no quality problems can be found after testing by 

Culligan personnel�
Some states do not allow the exclusion of implied warranties or limitations on how long an implied warranty lasts, so the above 

limitation may not apply to you� Similarly, some states do not allow the exclusion of incidental or consequential damages, so the 

above limitation or exclusion may not apply to you� This warranty gives you specific legal rights, and you may also have other 

rights which vary from state to state� Consult your telephone directory for your local independently operated Culligan dealer, or 

write Culligan International Company for warranty and service information�

Culligan International Company

9399 W� Higgins Rd�, Suite 1100 

Rosemont, IL 60018 USA 

1-800-CULLIGAN or 1-847-430-2800

www.culligan.com

Summary of Contents for Aquasential RO

Page 1: ...Aquasential RO and Smart RO Advanced Drinking Water Systems Models from 2021 DCO 210105 06 03 21 CAT 01040605 Rev A 2021 Culligan International Company...

Page 2: ...Analytical Laboratory is certified to perform coliform and E coli testing We strive to provide our customers with the testing they need at the lowest possible cost with the quickest turn around time S...

Page 3: ...Customer 5 Thank You 7 Specifications 9 Application Operation 11 Navigation 14 Things to Check Before You Call 16 Care Cleaning 17 Performance Data Sheet 18 Records Data 32 Culligan Limited Warranty 3...

Page 4: ...paragraphs are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and careful attention are conditions which cannot be built into...

Page 5: ...und fault circuit interrupter GFCI GROUNDING INSTRUCTIONS This appliance must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a pat...

Page 6: ...is 25 2 C The full battery charging cycle 6 0V to 8 4V takes approximately 8 5 hours As a safety precaution charging terminates after 11 25 hours To start charging plug the 12V power supply in the fro...

Page 7: ...for specific performance claims as verified and substantiated by test data See performance data sheet included in this manual for specific claims Model ESP32 WROOM 32D used in Aquasential Smart RO Con...

Page 8: ...ion Sciences et D veloppement conomique Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouil...

Page 9: ...er than 10 gpg will reduce the life of the membrane The Arsenic cartridge must be installed after the RO membrane All specialty cartridges must have a Performance Indicator Device PID installed to tra...

Page 10: ...eral TD Min 1 1 year or 1 000 gallons TD Min 2 2 year or 2 000 gallons Specialty Remineralization Min 1 1 year or 1 000 gallons Min 2 2 year or 2 000 gallons Specialty Arsenic AS3 1 1 year or 1 000 ga...

Page 11: ...te Total Dissolved Solids The minimum driving force which is necessary to stop or reverse the natural osmosis process is termed osmotic pressure As the total dissolved solids level of the feed water i...

Page 12: ...e only a certain percentage of contaminants can pass through Reverse Osmosis can reduce up to 99 of contaminants Advanced Filtration The advanced filtration cartridges are specifically designed to red...

Page 13: ...h lab For more information please contact your local Culligan dealer Additional information about the arsenic in water can be found through the EPA s website at www epa gov There are two forms of arse...

Page 14: ...ed Wi Fi blinks during Bluetooth pairing Blue blink Wi Fi blinks during Wi Fi pairing Green blink Wi Fi when Wi Fi connection lost Red blink LED Indicators on the RO unit 1 Year Filter 2 Year Filter I...

Page 15: ...is in use Figure 2 Faucet LED indicators NOTE Wi Fi icon will only illuminate red if the device was previously connected but now can no longer connect router unplugged changed Wi Fi password router h...

Page 16: ...sure seem low there won t be very much water in the storage tank Check the shut off valve on the storage tank to be sure it is open Constant Running to Drain The system should run a small amount of wa...

Page 17: ...iciency of the system in order to determine when the RO membrane should be replaced and ensure the system is working properly Any time the water is going to be turned off to the unit the power should...

Page 18: ...articulate class 1 and chloramine and NSF ANSI 53 for the reduction of cyst lead mercury VOC MTBE perfluooroctanoic acid PFOA and perfluorooctane sulfonate PFOS and NSF ANSI 58 for the reduction of cy...

Page 19: ...00 10 1 3 96 5 97 6 99 1 99 2 99 2 99 1 99 2 99 2 Flouride 8 0 10 1 5 96 3 95 2 97 6 96 8 96 8 97 6 96 8 96 8 Radium 226 2282 25 pCi L 10 5 pCi L 97 8 98 2 99 0 99 0 99 0 99 0 99 0 99 0 Selenium 0 10...

Page 20: ...PID NSF ANSI Standard 53 Substance Influent Challenge Concen tration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model TD 1 Model TD 2 Aqua sential RO Aq...

Page 21: ...97 5 Atenolol Tenormin 200 ng L 20 30 ng L 85 0 94 2 94 2 94 2 94 2 94 2 94 2 94 2 DEET DEET 1 400 20 200 ng L 85 71 98 7 98 7 98 7 98 7 98 7 98 7 98 7 Linuron Linuron 140 20 20 ng L 85 71 96 6 96 6 9...

Page 22: ...tance Influent Challenge Concen tration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model TD Min 1 Model TD Min 2 Aqua sential RO Aqua sential Smart RO A...

Page 23: ...7 5 97 5 Atenolol Tenormin 200 ng L 20 30 ng L 85 0 94 2 94 2 94 2 94 2 94 2 94 2 94 2 DEET DEET 1 400 20 200 ng L 85 71 98 7 98 7 98 7 98 7 98 7 98 7 98 7 Linuron Linuron 140 20 20 ng L 85 71 96 6 96...

Page 24: ...0 088 0 005 1 1 Dichloroethylene 0 083 0 001 Cis 1 2 Dichloroethylene 0 170 0 001 Trans 1 2 Dichloroethylene 0 086 0 001 1 2 Dichloropropane 0 080 0 001 Cis 1 3 Dichloropropylene 0 079 0 001 Dinoseb 0...

Page 25: ...oethane 0 081 0 001 Tetrachloroethylene 0 081 0 001 Toluene 0 078 0 001 2 4 5 tp Silvex 0 270 0 002 Tribromoacetic Acid 0 042 0 001 1 2 4 Trichlorobenzene 0 160 0 001 1 1 1 Trichloroethane 0 084 0 005...

Page 26: ...Concentration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model Aquasential RO Pre 1 RO 50 and Post Adv 1 Aquasential Smart RO Pre 1 RO 75 and Post Adv...

Page 27: ...rivalent reduction See Arsenic Fact section for an explanation of reduction performance NSF ANSI Standard 53 Substance Influent Challenge Concen tration Maximum Permissible Product Water Concen tratio...

Page 28: ...6 97 6 Lead 0 16 0 003 0 005 98 1 98 1 Nitrate5 27 0 10 10 0 72 7 72 7 Nitrite 3 0 10 1 0 73 9 73 9 Radium 226 2283 25pCi L 5pCi L 5pCi L 99 0 99 0 Selenium 0 104 0 0016 0 00205 98 5 98 5 Cyst4 50 000...

Page 29: ...99 2 Fluoride 8 2 0 3 0 039 96 8 96 8 Lead 0 16 0 002 0 002 Nitrate5 27 0 10 10 0 Nitrite 3 0 10 1 0 Radium 226 2283 25pCi L 5pCi L 5pCi L 99 0 99 0 Selenium 0 104 0 0016 0 00182 98 5 98 5 Cyst4 50 0...

Page 30: ...Tank 34 1 gpd Prod Rate without Storage Tank To Atmosphere 34 1 gpd Efficiency Rating2 54 7 Recovery Rating3 52 8 Influent Challenge Concentration Mg L 737 Max Permissible Product Water Concentration...

Page 31: ...d on water supplies containing a detectable free chlorine residual or on water supplies that have been demonstrated to contain only pentavalent arsenic Treatment with chloramine combined chlorine is n...

Page 32: ...No Date Installed For Service Call Culligan at Date Serviced Cartridge s Changed Feed TDS Product TDS 1 Port Prefilter 2 Port RO Membrane 3 Port Specialty Filter 4 Port Postfilter 32 01040605 A 06 21...

Page 33: ...iod specified above for the entire conditioner As a manufacturer we do not know the characteristics of your water supply or the purpose for which you are purchasing a water treatment system The qualit...