Substance Reduction
1
Aquasential RO/Aquasential Smart RO with Post-filter (Post 1 P/N 01038123, Post 2 P/N 01038124)
These systems have been tested and certified by the Water Quality Association according to NSF/ANSI 58, NSF/ANSI 42, and CSA B483�1
for the reduction of the substances listed below� The concentration of the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for water leaving the system, as specified by NSF/ANSI 58, NSF/ANSI 42, and
CSA B483�1� While testing was performed under standard laboratory conditions, actual performance may vary�
Substance
Influent
Challenge
Concentration
(mg/L)
Max.
Permissible
Product
Water
Concen-
tration
(mg/L)
Minimum
Percent
Removal
RO & RO
(2yr)
Minimum
Percent
Removal
Aquasential
Smart RO &
Smart RO
(2yr)
Aqua-
sential
RO
Aqua-
sential
Smart
RO
Aqua-
sential
Smart
RO
Nitrate
Aqua-
sential
RO
(2yr)
Aqua-
sential
Smart
RO
(2yr)
Aqua-
sential
Smart
RO
(2yr)
Nitrate
Flow Rate = 0.75 gpm (2.84 Lpm)*
Capacity 1,000 gallons
(3786 L)*
Capacity 2,000 gallons
(7570 L)*
Average Percent Removal
Aesthetic
Chlorine*
2�0 +/- 10%
>50%
>50%
94�6%
94�6%
94�6%
94�6%
94�6%
94�6%
Arsenic
(pentavalent)²
0�050 +/- 10%
0�010
99�0%
97�2%
99�0%
98�8%
98�8%
99�0%
98�8%
98�8%
Barium
10�0 +/- 10%
2�0
97�8%
98�2%
99�0%
99�0%
99�0%
99�0%
99�0%
99�0%
Cadmium
0�03 +/- 10%
0�005
97�5%
74�5%
98�4%
94�7%
94�7%
98�4%
94�7%
94�7%
Hexavalent
Chromium
0�30 +/- 10%
0�1
94�4%
92�6%
96�2%
94�4%
94�4%
96�2%
94�4%
94�4%
Trivalent
Chromium
0�30 +/- 10%
0�1
95�1%
73�9%
96�0%
91�3%
91�3%
96�0%
91�3%
91�3%
Copper
3�00 +/- 10%
1�3
96�5%
97�6%
99�1%
99�2%
99�2%
99�1%
99�2%
99�2%
Flouride
8�0 +/- 10%
1�5
96�3%
95�2%
97�6%
96�8%
96�8%
97�6%
96�8%
96�8%
Radium
226/2282
25 pCi/L
+/- 10%
5 pCi/L
97�8%
98�2%
99�0%
99�0%
99�0%
99�0%
99�0%
99�0%
Selenium
0�10 +-/10%
0�05
98�0%
98�3%
98�5%
98�5%
98�5%
98�5%
98�5%
98�5%
Turbidity
11 NTU
0�1 NTU
99�4%
99�3%
99�3%
99�4%
99�3%
99�3%
Cyst⁴
>50,000 / mL
>99�99% >99�99% >99�99% >99�99% >99�99% >99�99%
TDS
750 +/- 5%
187
89�6%
88�5%
92�5%
91�7%
92�5%
91�7%
Lead
0�15 +/- 10%
0�005
96�8%
98�1%
-
98�1%
-
Nitrate⁵
27�00 +/- 10%
10�0
62�8%
72�7%
-
72�7%
-
Nitrite
3�00 +/- 10%
1�0
65�3%
73�9%
-
73�9%
-
* Flow rate and capacity information is applicable to aesthetic chlorine reduction�
¹ While testing was performed under standard laboratory conditions, actual performance may vary depending on water pressure, temperatures and other
substances, which may be found in your water�
² These systems have been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations of
0�050 mg/L or less� This system reduces pentavalent arsenic, but may not remove other forms of arsenic� These systems are to be used on water supplies
containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic�
Treatment with chloramines (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic� Please see the
Arsenic Facts Sheet for further information�
³ Based upon testing methods using Barium as a surrogate� All concentrations in pCi/L pico curie/L�
⁴ Includes Giardia lamblia, Entamoeba histolyca and Cryptosporidium.
⁵ Units are not certified on water supplies with a pressure less than 40 psi (280 kPa). A booster pump is strongly recommended.