background image

21

01040605  A  06/21

NSF/ANSI Standard 401

Substance

Common 

Name

Influent 

Challenge 

Concentration

Maximum 

Permissible 

Product 

Water 

Concen-

tration

Reduction 

Require-

ments

Minimum 

Reduction

Model: TD 1

Model: TD 2

Aqua-

sential 

RO

Aqua-

sential 

Smart 

RO

Aqua-

sential 

Smart 

RO 

Nitrate

Aqua-

sential 

RO 

(2yr)

Aqua-

sential 

Smart 

RO 

(2yr)

Aqua-

sential 

Smart 

RO 

(2yr) 

Nitrate

Flow Rate = 0.5 gpm (1.89 Lpm)

Capacity 1,000 gallons  

(3786 L)

Capacity 2,000 gallons  

(7570 L)

Average Reduction

Phenytoin

Dilantin

1

200 ng/L ± 20%

30 ng/L

85�0%

95�5%

>95�6%

>95�6%

>95�6%

>95�6%

>95�6%

>95�6%

Ibuprofen

Motrin

1

400 ± 20%

60 ng/L

85�0%

95�3%

>95�4%

>95�4%

>95�4%

>95�4%

>95�4%

>95�4%

Naproxen

Aleve

1

140 ± 20%

20 ng/L

85�71%

96�3%

>96�4%

>96�4%

>96�4%

>96�4%

>96�4%

>96�4%

Estrone

Estrogen

140 ± 20%

20 ng/L

85�71%

96�3%

>96�5%

>96�5%

>96�5%

>96�5%

>96�5%

>96�5%

Bisphenol A

BPA

2,000 ± 20%

300 ng/L

85�0%

98�8%

>98�9%

>98�9%

>98�9%

>98�9%

>98�9%

>98�9%

Nonylphenol

Nonylphenol

1,400 ± 20%

200 ng/L

85�71%

97�5%

>97�5%

>97�5%

>97�5%

>97�5%

>97�5%

>97�5%

Atenolol

Tenormin¹

200 ng/L ± 20%

30 ng/L

85�0%

94�2%

>94�2%

>94�2%

>94�2%

>94�2%

>94�2%

>94�2%

DEET

DEET

1,400 ± 20%

200 ng/L

85�71%

98�7%

>98�7%

>98�7%

>98�7%

>98�7%

>98�7%

>98�7%

Linuron

Linuron

140 ± 20%

20 ng/L

85�71%

96�6%

>96�6%

>96�6%

>96�6%

>96�6%

>96�6%

>96�6%

Carbamazepine

Tegretol¹

1,400 ± 20%

200 ng/L

85�71%

98�6%

>98�6%

>98�6%

>98�6%

>98�6%

>98�6%

>98�6%

Trimethoprim

Trimethoprim

140 ± 20%

20 ng/L

85�71%

96�7%

>96�7%

>96�7%

>96�7%

>96�7%

>96�7%

>96�7%

Metolachlor

Metolachlor

1,400 ± 20%

200 ng/L

85�71%

98�6%

>98�6%

>98�6%

>98�6%

>98�6%

>98�6%

>98�6%

TCEP

TCEP

5,000 ± 20%

700 ng/L

86�0%

98�0%

>98�0%

>98�0%

>98�0%

>98�0%

>98�0%

>98�0%

TCPP

TCPP

5,000 ± 20%

700 ng/L

86�0%

97�8%

>97�8%

>97�8%

>97�8%

>97�8%

>97�8%

>97�8%

Meprobamate

Meprobamate

400 ± 20%

60 ng/L

85�0%

94�7%

>95�1%

>95�1%

>94�7%

>95�1%

>95�1%

>94�7%

1,000 and 2,000 gallon capacity is only for use with PID

NSF/ANSI Standard 401 are considered incidental contaminants and emerging compounds�

¹Dilantin is a registered trademark of Pfizer Inc� Motrin is a registered trademark of Johnson & Johnson Consumer Inc� Aleve is a registered trademark of 

Bayer� Tenormin registered trademark of the AstraZeneca UK Ltd Tenormin is a registered trademark of Novartis Pharmaceuticals Corporation�

Summary of Contents for Aquasential RO

Page 1: ...Aquasential RO and Smart RO Advanced Drinking Water Systems Models from 2021 DCO 210105 06 03 21 CAT 01040605 Rev A 2021 Culligan International Company...

Page 2: ...Analytical Laboratory is certified to perform coliform and E coli testing We strive to provide our customers with the testing they need at the lowest possible cost with the quickest turn around time S...

Page 3: ...Customer 5 Thank You 7 Specifications 9 Application Operation 11 Navigation 14 Things to Check Before You Call 16 Care Cleaning 17 Performance Data Sheet 18 Records Data 32 Culligan Limited Warranty 3...

Page 4: ...paragraphs are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and careful attention are conditions which cannot be built into...

Page 5: ...und fault circuit interrupter GFCI GROUNDING INSTRUCTIONS This appliance must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a pat...

Page 6: ...is 25 2 C The full battery charging cycle 6 0V to 8 4V takes approximately 8 5 hours As a safety precaution charging terminates after 11 25 hours To start charging plug the 12V power supply in the fro...

Page 7: ...for specific performance claims as verified and substantiated by test data See performance data sheet included in this manual for specific claims Model ESP32 WROOM 32D used in Aquasential Smart RO Con...

Page 8: ...ion Sciences et D veloppement conomique Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouil...

Page 9: ...er than 10 gpg will reduce the life of the membrane The Arsenic cartridge must be installed after the RO membrane All specialty cartridges must have a Performance Indicator Device PID installed to tra...

Page 10: ...eral TD Min 1 1 year or 1 000 gallons TD Min 2 2 year or 2 000 gallons Specialty Remineralization Min 1 1 year or 1 000 gallons Min 2 2 year or 2 000 gallons Specialty Arsenic AS3 1 1 year or 1 000 ga...

Page 11: ...te Total Dissolved Solids The minimum driving force which is necessary to stop or reverse the natural osmosis process is termed osmotic pressure As the total dissolved solids level of the feed water i...

Page 12: ...e only a certain percentage of contaminants can pass through Reverse Osmosis can reduce up to 99 of contaminants Advanced Filtration The advanced filtration cartridges are specifically designed to red...

Page 13: ...h lab For more information please contact your local Culligan dealer Additional information about the arsenic in water can be found through the EPA s website at www epa gov There are two forms of arse...

Page 14: ...ed Wi Fi blinks during Bluetooth pairing Blue blink Wi Fi blinks during Wi Fi pairing Green blink Wi Fi when Wi Fi connection lost Red blink LED Indicators on the RO unit 1 Year Filter 2 Year Filter I...

Page 15: ...is in use Figure 2 Faucet LED indicators NOTE Wi Fi icon will only illuminate red if the device was previously connected but now can no longer connect router unplugged changed Wi Fi password router h...

Page 16: ...sure seem low there won t be very much water in the storage tank Check the shut off valve on the storage tank to be sure it is open Constant Running to Drain The system should run a small amount of wa...

Page 17: ...iciency of the system in order to determine when the RO membrane should be replaced and ensure the system is working properly Any time the water is going to be turned off to the unit the power should...

Page 18: ...articulate class 1 and chloramine and NSF ANSI 53 for the reduction of cyst lead mercury VOC MTBE perfluooroctanoic acid PFOA and perfluorooctane sulfonate PFOS and NSF ANSI 58 for the reduction of cy...

Page 19: ...00 10 1 3 96 5 97 6 99 1 99 2 99 2 99 1 99 2 99 2 Flouride 8 0 10 1 5 96 3 95 2 97 6 96 8 96 8 97 6 96 8 96 8 Radium 226 2282 25 pCi L 10 5 pCi L 97 8 98 2 99 0 99 0 99 0 99 0 99 0 99 0 Selenium 0 10...

Page 20: ...PID NSF ANSI Standard 53 Substance Influent Challenge Concen tration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model TD 1 Model TD 2 Aqua sential RO Aq...

Page 21: ...97 5 Atenolol Tenormin 200 ng L 20 30 ng L 85 0 94 2 94 2 94 2 94 2 94 2 94 2 94 2 DEET DEET 1 400 20 200 ng L 85 71 98 7 98 7 98 7 98 7 98 7 98 7 98 7 Linuron Linuron 140 20 20 ng L 85 71 96 6 96 6 9...

Page 22: ...tance Influent Challenge Concen tration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model TD Min 1 Model TD Min 2 Aqua sential RO Aqua sential Smart RO A...

Page 23: ...7 5 97 5 Atenolol Tenormin 200 ng L 20 30 ng L 85 0 94 2 94 2 94 2 94 2 94 2 94 2 94 2 DEET DEET 1 400 20 200 ng L 85 71 98 7 98 7 98 7 98 7 98 7 98 7 98 7 Linuron Linuron 140 20 20 ng L 85 71 96 6 96...

Page 24: ...0 088 0 005 1 1 Dichloroethylene 0 083 0 001 Cis 1 2 Dichloroethylene 0 170 0 001 Trans 1 2 Dichloroethylene 0 086 0 001 1 2 Dichloropropane 0 080 0 001 Cis 1 3 Dichloropropylene 0 079 0 001 Dinoseb 0...

Page 25: ...oethane 0 081 0 001 Tetrachloroethylene 0 081 0 001 Toluene 0 078 0 001 2 4 5 tp Silvex 0 270 0 002 Tribromoacetic Acid 0 042 0 001 1 2 4 Trichlorobenzene 0 160 0 001 1 1 1 Trichloroethane 0 084 0 005...

Page 26: ...Concentration Maximum Permissible Product Water Concen tration Reduction Require ments Minimum Reduction Model Aquasential RO Pre 1 RO 50 and Post Adv 1 Aquasential Smart RO Pre 1 RO 75 and Post Adv...

Page 27: ...rivalent reduction See Arsenic Fact section for an explanation of reduction performance NSF ANSI Standard 53 Substance Influent Challenge Concen tration Maximum Permissible Product Water Concen tratio...

Page 28: ...6 97 6 Lead 0 16 0 003 0 005 98 1 98 1 Nitrate5 27 0 10 10 0 72 7 72 7 Nitrite 3 0 10 1 0 73 9 73 9 Radium 226 2283 25pCi L 5pCi L 5pCi L 99 0 99 0 Selenium 0 104 0 0016 0 00205 98 5 98 5 Cyst4 50 000...

Page 29: ...99 2 Fluoride 8 2 0 3 0 039 96 8 96 8 Lead 0 16 0 002 0 002 Nitrate5 27 0 10 10 0 Nitrite 3 0 10 1 0 Radium 226 2283 25pCi L 5pCi L 5pCi L 99 0 99 0 Selenium 0 104 0 0016 0 00182 98 5 98 5 Cyst4 50 0...

Page 30: ...Tank 34 1 gpd Prod Rate without Storage Tank To Atmosphere 34 1 gpd Efficiency Rating2 54 7 Recovery Rating3 52 8 Influent Challenge Concentration Mg L 737 Max Permissible Product Water Concentration...

Page 31: ...d on water supplies containing a detectable free chlorine residual or on water supplies that have been demonstrated to contain only pentavalent arsenic Treatment with chloramine combined chlorine is n...

Page 32: ...No Date Installed For Service Call Culligan at Date Serviced Cartridge s Changed Feed TDS Product TDS 1 Port Prefilter 2 Port RO Membrane 3 Port Specialty Filter 4 Port Postfilter 32 01040605 A 06 21...

Page 33: ...iod specified above for the entire conditioner As a manufacturer we do not know the characteristics of your water supply or the purpose for which you are purchasing a water treatment system The qualit...

Reviews: