30
01040605 A 06/21
Output (Total Dissolved Solids (TDS) Reduction and Output Production)
1
– RO 50
Tank Size
3 gallons
Product System Daily Prod� Rate To Pressurized Storage Tank
27�8 gpd
Prod� Rate without Storage Tank To Atmosphere
28�0 gpd
Efficiency Rating
2
23�2%
Recovery Rating
3
39�2%
Influent Challenge Concentration (Mg/L)
737
Max� Permissible Product Water Concentration (Mg/L)
187
Minimum Percent Removal
89�6%
Average Percent Removal
92�5%
1
These systems have been tested under standard laboratory conditions� Actual production rate and TDS rejection will depend on
temperature, water pressure, TDS level, membrane variation and usage pattern�
2
Efficiency rating means the percentage of the influent water to the system that is available to the user are reverse osmosis treated water
under operating conditions that approximate daily usage�
3
Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as
reverse osmosis treated water when the systems are operated without a storage tank or when the storage tank is bypassed�
Output (Total Dissolved Solids (TDS) Reduction and Output Production)
1
– RO 75
Tank Size
3 gallons
Product System Daily Prod� Rate To Pressurized Storage Tank
34�1 gpd
Prod� Rate without Storage Tank To Atmosphere
34�1 gpd
Efficiency Rating
2
54�7%
Recovery Rating
3
52�8%
Influent Challenge Concentration (Mg/L)
737
Max� Permissible Product Water Concentration (Mg/L)
187
Minimum Percent Removal
88�5%
Average Percent Removal
90�4%
1
These systems have been tested under standard laboratory conditions� Actual production rate and TDS rejection will depend on
temperature, water pressure, TDS level, membrane variation and usage pattern�
2
Efficiency rating means the percentage of the influent water to the system that is available to the user are reverse osmosis treated water
under operating conditions that approximate daily usage�
3
Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as
reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed�
Testing Conditions (Complete System)
Temperature:
77 F + 2 F
Pressure:
50 psi
pH:
7�5 + 0�5
Turbidity:
<1 NTU
These systems have been tested and shown to operate at their calculated recovery rating under standard laboratory conditions�
These reverse osmosis systems contain a replaceable component critical to the efficiency of the systems� Replacement of
the reverse osmosis component should be with one of identical specifications, as defined by the manufacturer, to assure
the same efficiency and contaminant reduction performance�