C550c Operation Manual
5 System setup
99
5.4 Calibrate the equipment
Every time you power up the controller, you will need to confirm what equipment is connected to the
C550c controller.
Briefly, after the setup wizard is complete, in the Equipment settings menu, select the drum type,
crawler, crawler wheel size, camera type and other equipment that is currently attached to the controller.
Then select the
Continue
menu item.
You will then continue to the controller home screen.
If you have a pushrod connected you will be advised to rewind the pushrod fully onto the reel (coiler).
Make sure the pushrod is layered evenly and correctly onto the reel and the end of the rod is level with
the rod guide.
Press the Calibrate button to calibrate the reel.
After calibrating the reel, press the
Back
button or Esc key to return to the controller home screen.
You can now use the Settings menus to configure the system; continue to
page 101
Note: For definitions of calibration and zero distance, see
page 22