Last Revised 05/09/2013
19
In order to ensure that only this camera ID and/or Baud Rate will be changed you will
see that in the
COMMS SETTINGS
menu there is a blank field to the right of
INPUT SN
and underneath this a unique camera serial number to the right of
SN.
When the last digit of the serial number is entered press the
IRIS+
or
OPEN
key to
save it and then press the
IRIS-
or
CLOSE
key to exit. The changes will then take
effect. Note that the
INPUT SN
serial number will return to a blank field to allow a
new change to be made if required.
Setup of the Protocol
There are no dipswitches in this PTZ allowing protocol changes. The protocol is self-
detected and is automatically selected from either PELCO-D or PELCO-P.
You need to re-enter this unique serial
number in order for the ID and/or Baud Rate
change to take effect.
Move down to
INPUT SN
and press the
IRIS+
or
OPEN
key to enter this unique
number.
Write down the serial number and then
press the
IRIS+
or
OPEN
key.
Using the left or right direction key move
the arrow under the first digit of the serial
number and press the
IRIS+
or
OPEN
key
to select the required digit and then press
the
IRIS+
or
OPEN
key again to select it.