6
Aerial work platform
ZED 20.3 HV
COD. UM0284_GB | REV. 0.0 | ED: 09/17
GB
Chapter 12
TROUBLESHOOTING
Alarm code
Description
AlArM1
AlArM2
ErrOr TOrr
0x
08
01
spieAlarm_installAngRotTorr
02
spieAlarm_inceppRotTorr
03
spieAlarm_inceppDiscesa
04
spieAlarm_inceppSilo
12.2.1
Reset alarms
To access the switch with a red cover (Fig. 12.2):
•
open the cover panel (1) which is found on the bed of the vehicle;
•
open the cover panel to the compartment (2);
•
then, open the panel (3) covering the box which contains the Safety and Carriage engine control
units;
•
the errors are reset by lipping the switch with the red safety cover (4). Move and hold the switch
into position once for ive seconds until the alarm LEDs (ALARM 1, ALARM 2) lash quickly.
•
Now reset the switch into itsinitial position with the safety cover in position and check that the
alarm LEDs are off;
•
Close the various panels securely.
4
3
2
1
Fig.
12.2