Chapter 4. Web Configuration & Operation
79
CHAPTER 3
WEB OPERATION & CONFIGURATION
Link Event can be configured on a per-port basis. Select the desire port number from the pull-down menu to configure
its Link Event settings.
Event Name:
Ethernet OAM entities monitor link status by exchanging Event Notification OAMPDUs. When one of the
events listed here is detected, an OAM entity sends an Event Notification OAMPDU to its peer OAM entity.
Error Frame Event:
The Errored Frame Event counts the number of errored frames detected during the specified
period. The period is specified by a time interval (Window in order of 1 sec). This event is generated if the errored
frame count is equal to or greater than the specified threshold for that period (Period Threshold). Errored frames
are frames that had transmission errors as detected at the Media Access Control sublayer. Error Window for
'Error Frame Event' must be an integer value between 1-60 and its default value is '1'. Whereas Error Threshold
must be between 0-0xffffffff and its default value is '0'.
Symbol Period Error Event:
The Errored Symbol Period Event counts the number of symbol errors that occurred
during the specified period. The period is specified by the number of symbols that can be received in a time
interval on the underlying physical layer. This event is generated if the symbol error count is equal to or greater
than the specified threshold for that period. Error Window for 'Symbol Period Error Event' must be an integer
value between 1-60 and its default value is '1'. Whereas Error Threshold must be between 0-0xffffffff and its
default value is '0'.
Seconds Summary Event:
The Errored Frame Seconds Summary Event TLV counts the number of errored frame
seconds that occurred during the specified period. The period is specified by a time interval. This event is
generated if the number of errored frame seconds is equal to or greater than the specified threshold for that
period. An errored frame second is a one second interval wherein at least one frame error was detected. Errored
frames are frames that had transmission errors as detected at the Media Access Control sublayer. Error Window
for 'Seconds Summary Event' must be an integer value between 10-900 and its default value is '60'. Whereas
Error Threshold must be between 0-0xffff and its default value is '1'.
Error Window:
Specify the window period in the order of 1 sec for the observation of various link events.
Error Threshold:
Specify the error threshold value for the window period for the appropriate Link event so as to notify
the peer of this error.
3.6.3 Port Statistics
Rx & Tx OAM Information PDU’s:
The number of received and transmitted OAM Information PDU's. Discontinuities of
this counter can occur at re-initialization of the management system.
Rx & Tx Unique Error Event Notification:
A count of the number of unique Event OAMPDUs received and transmitted
on this interface. Event Notifications may be sent in duplicate to increase the probability of successfully being received,
given the possibility that a frame may be lost in transit. Duplicate Event Notification transmissions are counted by
Duplicate Event Notification counters for Tx and Rx respectively. A unique Event Notification OAMPDU is indicated as