Appendix A. DIP SW. Setting ETU01U-Plus
36
B.3 DIP SW6 Parameter Group 2 Setting
DIP SW6
NO.
STATE
STATE
FUNCTION COMMENT
OFF
Line Impedance: 120 Ohm
TP (RJ-45)
-1
ON
Line Impedance: 75 Ohm
Coaxial (BNC)
OFF
RC Phase: Normal
-2
ON
RC Phase: Inverted
OFF
TC Phase: Normal
-3
ON
TC Phase: Inverted
OFF
DCD always ON, except E1 Sig.Loss
-4
ON
DCD follows RTS, except E1 Sig.Loss
OFF
Synchronous
(see Note 1)
-5
ON Asynchronous
OFF Reserved
-6
ON Reserved
OFF
Data port loopback: Disable
-7
ON
Data port loopback: Enable
OFF
Front panel push buttons: Disable
-8
ON
Front panel push buttons: Enable
Table B.3 DIP SW6 Parameter Group 2 Setting
Note 1: In normal operation this switch should be left OFF. However, if running a
transparent asynchronous application (TD, RD and no clock) enable this switch. This
will disable the automatic clock polarity function and allow error free transparent
operation. (Added in firmware version V1.2 and CPLD version V1.4)