Appendix A. DIP SW. Setting ETU01U-Plus
35
B.1 ETU01U-Plus All DIP Switch Overview
DIP SW
GROUP
FUNCTION COMMENT
5
Parameter group 1 setting
See Table B.2
6
Parameter group 2 setting
See Table B.3
Table B.1 All DIP Switch Overview
Note: The ETU01U-Plus operates in unframed mode ONLY. The user data rate is
fixed at 2048K. DIPSW1 to DIPSW4 are not installed on the PCBA. The settings for
DIPSW5 bits 5-8 and DIPSW6 bits 4-5 do not matter.
B.2 DIP SW5 Parameter Group 1 Setting
DIP SW5
NO.
STATE
STATE
FUNCTION COMMENT
OFF OFF OFF Clock mode 0 (DCE1)
ON OFF OFF Clock mode 1 (DCE1)
OFF ON OFF Clock mode 2 (DTE1)
ON ON OFF Clock mode 3 (DTE2)
OFF OFF ON Clock mode 4 (DTE3)
ON OFF ON Reserved
OFF ON ON Reserved
-1,-2,-3
ON ON ON Reserved
See Table A-9
OFF
Line code: HDB3
-4
ON
Line code: AMI
OFF Don't
care
-5
ON Don't
care
OFF Don't
care
-6
ON Don't
care
OFF Don't
care
-7
ON Don't
care
OFF Don't
care
-8
ON Don't
care
No function on
ETU01U-Plus
Table B.2 DIP SW5 Parameter Group 1 Setting