Diagnostics
Test Switches/Diagnostics
-Digital local loop back
-Analog local loop back
-Digital remote loop back
-Test pattern / generator
LED indicators
PWR Green
Power
TD Green
Transmit
data
RD Green
Receive
data
RTS
Green
Request to sent
DCD
Green
Data carrier detect
Tx CLK Loss
Red
Transmit clock loss
Signal Loss
Red
E1 line signal loss
Sync Loss
Red
E1 line sync loss
Alarm
Red
E1 line alarm, include: BPV error / CRC4 error
/ Frame slip / All ones(AIS) / Remote alarm
Error
Red
Bit errors during integral BERT
Test
Red
Loop back and pattern test enabled
Physical
Height:
45 mm (1 3/4")
Width:
195 mm (7 5/8")
Depth:
155 mm (6 1/8")
Weight:
0.5 kg (1 lb 2 oz)
Power supply
Voltage
90~250VAC (universal AC model)
18~75VDC (universal DC model)
Frequency
47 to 63 Hz for AC
Power consumption
10 Watts
Environment
Temperature
-10
°
~60
°
C / 15
°
~140
°
F
Humidity
0 to 95% non-condensing