Appendix A. DIP SW. Setting ETU01-Plus
32
A.6 DIP SW5 Parameter Group 1 Setting
DIP SW5
NO.
STATE
STATE
FUNCTION COMMENT
OFF OFF OFF Clock mode 0 (DCE1)
ON OFF OFF Clock mode 1 (DCE1)
OFF ON OFF Clock mode 2 (DTE1)
ON ON OFF Clock mode 3 (DTE2)
OFF OFF ON Clock mode 4 (DTE3)
ON OFF
ON Reserved
OFF
ON ON Reserved
-1,-2,-3
ON ON ON Reserved
See Table A-9
OFF
Line code: HDB3
-4
ON
Line code: AMI
OFF
Frame mode: CCS (PCM31)
-5
ON
Frame mode: CAS (PCM30)
OFF CRC4:
OFF
-6
ON CRC4:
ON
OFF
Idle code: Mark (0xFF)
-7
ON
Idle code: Flag (0x7E)
OFF
Data channel rate: N
×
64
-8
ON
Data channel rate: N
×
56
Table A.6 DIP SW5 Parameter Group 1 Setting