![CTC Union EcoPart 425-435 Installation And Maintenance Manual Download Page 12](http://html1.mh-extra.com/html/ctc-union/ecopart-425-435/ecopart-425-435_installation-and-maintenance-manual_2693353012.webp)
12
CTC EcoPart i425-i435 Pro
General Information
2.2 Table 230 V 1N~
230V 1N~
CTC EcoPart i425 Pro
CTC EcoPart i430 Pro
KM414EP 2xLEP
KM410EP 2xLEP
KM14EP 2xLEP
KM414EP 2xLEP
CTC EcoLogic Pro
CTC EcoLogic Pro
kW
15.3
17.2
A
33.5
33.5
38.0
38.0
IPX1
IPX1
A
47.7
54.2
A
27.1
20.6
27.1
27.1
CTC EcoPart 425
CTC EcoPart 430
KM414EP 2xLEP
KM410EP 2xLEP
KM414EP 2xLEP
KM414EP 2xLEP
CTC Basic display
CTC Basic display
kW
10.7
12.6
A
24.0
24.0
28.0
28.0
IPX1
IPX1
A
47.7
54.2
A
27.1
20.6
27.1
27.1
A
30.0
30.0
30.0
30.0
230V 1N~
kW
20.42
24.18
kW
12.09
8.33
12.09
12.09
COP
1)
@ -5/45
3.24
3.30
3.24
3.24
kW
24.44 | 24.48 | 22.68
28.94 | 27.86 | 26.80
kW
14.47 | 13.93 |13.40
9.97 | 9.55 | 9.28
14.47 | 13.93 |13.40
14.47 | 13.93 |13.40
COP
1)
@ 0/35 0/45 0/55
4.54 | 3.64 | 2.95
4.60 | 3.68 | 2.98
4.54 | 3.64 | 2.95
4.54 | 3.64 | 2.95
kW
27.90 | 26.97 | 25.86
32.96 | 31.96 | 30.56
kW
16.48 | 15.98 | 15.28
11.42 | 10.99 | 10.58
16.48 | 15.98 | 15.28
16.48 | 15.98 | 15.28
COP
1)
@ 5/35 5/45 5/55
5.13 | 4.11 | 3.28
5.20 | 4.16 | 3.28
5.13 | 4.11 | 3.28
5.13 | 4.11 | 3.28
230V 1N~
l
4.07
2.90
4.07
4.07
ºC
-5 / 20
bar
0.2 / 3.0
0.2 / 3.0
l/s
0.53
0.38
0.53
0.53
l/s
0.88
0.64
0.88
0.88
8.7
8.1
8.7
8.7
230V 1N~
l
2.7
1.9
2.7
2.7
4.790
3.371
4.790
4.790
Polyolester (POE)
MPa
3.1 (31 bar)
dB(A)
45.6
45.4
kg
334
354
mm
596 x 1760 x 680
230V 1N~
ºC
110
l/s
0.34
0.24
0.34
0.34
8.6
4.3
8.6
8.6
l/s
0.68
0.48
0.68
0.68
LEP (Low Energy Pump)
1-Fas
Electrical data
Name
Type
Operating system
Rated power
Rated current
IP class
Max. operating current Compressors
Max. operating current Compressor
Name
Type
Operating system
Rated power
Rated current
IP class
Max. operating current Compressors
Max. operating current Compressor
Max starting current
Operational data for heat pump
Output from compressor
1)
@ -5/45
Output from compressor
1)
@ -5/45
Output from compressor
1)
@ 0/35 0/45 0/55
Output from compressor
1)
@ 0/35 0/45 0/55
Output from compressor
1)
@ 5/35 5/45 5/55
Output from compressor
1)
@ 5/35 5/45 5/55
1)
EN14511:2007, inclusive circulation pumps
Brine system
Water volume (V)
Brine system min/max temp. (TS)
Brine system min/max pressure (PS)
Brine system min fl ow ∆t = 5 K
Brine system nominal fl ow ∆t = 3 K
Kvs value ∆t = 3 K at nominal fl ow
Brine system pump
Class A circulation pump (LEP)
Pump capacity
See diagram in the Pipe installation chapter
Other data
Refrigerant quantity (R407C, fl uorinated
greenhouse gases GWP 1774)
CO
2
equivalent
Compressor oil
Pressure switch cut-off HT
Sound power EN 12102 +/-2 dB(A)
Weight net
Width x Height x Depth
Heating system
Max temperature heating medium (TS)
Heating system min fl ow
2)
Kvs value ∆t = 10 K, at min fl ow
Heating system nominal fl ow
3)
Heating medium pump
2)
∆t = 10 K och 0/35 °C heat pump operation.
3)
∆t = 5 K och 0/35 °C heat pump operation.
1-Fas
No annual leakage control of the refrigerant is required
Summary of Contents for EcoPart 425-435
Page 31: ...31 CTC EcoPart i425 i435 Pro General Information ...
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com ...