2.1 Table 400 V 3N~
400V 3N~
CTC EcoPart i425 Pro
CTC EcoPart i430 Pro
KM417EP 2xLEP
KM408EP 2xLEP
KM417EP 2xLEP
KM412EP 2xLEP
CTC EcoLogic Pro
CTC EcoLogic Pro
kW
15.4
17.0
A
22.2
24.6
IPX1
IPX1
A
16.7
19.7
A
11.5
5.2
11.5
8.2
CTC EcoPart 425
CTC EcoPart 430
KM417EP 2xLEP
KM408EP 2xLEP
KM417EP 2xLEP
KM412EP 2xLEP
CTC Basic display
CTC Basic display
kW
10.8
12.4
A
15.6
17.9
IPX1
IPX1
A
16.7
19.7
A
11.5
5.2
11.5
8.2
A
32.0
17.7
32.0
23.5
400V 3N~
kW
20.89
23.93
kW
14.05
6.84
14.05
9.88
COP
1)
@ -5/45
3.19
3.34
3.19
3.30
kW
24.43 | 24.01 | 23.42
27.99 | 27.38 | 26.84
kW
16.24 | 16.14 |15.87
8.19 | 7.87 | 7.55
16.24 | 16.14 | 15.87
11.75 | 11.24 | 10.97
COP
1)
@ 0/35 0/45 0/55
4.36 | 3.61 | 3.07
4.58 | 3.64 | 2.99
4.36 | 3.61 | 3.07
4.60 | 3.66 | 2.96
kW
28.69 | 27.47 | 26.81
32.78 | 31.37 | 30.73
kW
19.25 | 18.42 | 18.16
9.44 | 9.05 | 8.65
19.25 | 18.42 | 18.16
13.53 | 12.95 | 12.57
COP
1)
@ 5/35 5/45 5/55
5.02 | 4.05 | 3.38
5.02 | 4.04 | 3.30
5.02 | 4.05 | 3.38
5.11 | 4.11 | 3.35
400V 3N~
l
4.07
2.90
4.07
3.40
ºC
5 / 20
bar
0.2 / 3.0
0.2 / 3.0
l/s
0.63
0.31
0.63
0.44
l/s
1.05
0.51
1.05
0.73
8.9
5.8
8.9
7.2
400V 3N~
l
2.7
1.9
2.7
2.3
ton
4.790
3.371
4.790
4.080
Polyolester (POE)
MPa
3.1 (31 bar)
dB(A)
58.5
58.5
kg
334
354
mm
596 x 1760 x 680
400V 3N~
ºC
110
l/s
0.40
0.20
0.40
0.28
5.9 (6 kPa)
4.1 (3 kPa)
5.9 (6 kPa)
5.5 (3.5 kPa)
l/s
0.81
0.39
0.81
0.56
LEP (Low Energy Pump)
Electrical data
Name
Type
Operating system
Rated power
Rated current
IP class
Max. operating current Compressors
Max. operating current Compressor
Name
Type
Operating system
Rated power
Rated current
IP class
Max. operating current Compressors
Max. operating current Compressor
Max starting current
Operational data for heat pump
Output from compressor
1)
@ -5/45
Output from compressor
1)
@ -5/45
Output from compressor
1)
@ 0/35 0/45 0/55
Output from compressor
1)
@ 0/35 0/45 0/55
Output from compressor
1)
@ 5/35 5/45 5/55
Output from compressor
1)
@ 5/35 5/45 5/55
1)
EN14511:2007, inclusive circulation pumps
Brine system
Water volume (V)
Brine system min/max temp. (TS)
Brine system min/max pressure (PS)
Brine system min fl ow ∆t = 5 K
Brine system nominal fl ow ∆t = 3 K
Kvs value ∆t = 3 K at nominal fl ow
Brine system pump
Class A circulation pump (LEP)
Pump capacity
See diagram in the Pipe installation chapter
Other data
Refrigerant quantity (R407C, fl uorinated
greenhouse gases GWP 1774)
CO
2
equivalent
Compressor oil
Pressure switch cut-off HT
Sound power EN 12102 +/-2 dB(A)
Weight net
Width x Height x Depth
Heating system
Max temperature heating medium (TS)
Heating system min fl ow
2)
Kvs value ∆t = 10 K, at min fl ow
Heating system nominal fl ow
3)
Heating medium pump
2)
∆t = 10 K och 0/35 °C heat pump operation.
3)
∆t = 5 K och 0/35 °C heat pump operation.
No annual leakage control of the refrigerant is required