CTC EcoPart i425-i435 Pro
General Information
400V 3N~
CTC EcoPart i435 Pro
KM417EP 2xLEP
KM417EP 2xLEP
CTC EcoLogic Pro
kW
19.4
A
28.0
IPX1
A
23.0
A
11.5
11.5
CTC EcoPart 435
KM417EP 2xLEP
KM417EP 2xLEP
CTC Basic display
kW
14.8
A
21.4
IPX1
A
23.0
A
11.5
11.5
A
32.0
32.0
400V 3N~
kW
28.10
kW
14.05
14.05
COP
1)
@ -5/45
3.19
3.19
kW
32.48 | 32.28 | 31.74
kW
16.24 | 16.14 |15.87
16.24 | 16.14 |15.87
COP
1)
@ 0/35 0/45 0/55
4.36 | 3.61 | 3.07
4.36 | 3.61 | 3.07
kW
38.50 | 36.84 | 36.32
kW
19.25 | 18.42 | 18.16
19.25 | 18.42 | 18.16
COP
1)
@ 5/35 5/45 5/55
5.02 | 4.05 | 3.38
5.02 | 4.05 | 3.38
400V 3N~
l
4.07
4.07
ºC
5 / 20
bar
0.2 / 3.0
l/s
0.63
0.63
l/s
1.05
1.05
8.9
8.9
400V 3N~
l
2,7
2,7
ton
4.790
4.790
Polyolester (POE)
MPa
3.1 (31 bar)
dB(A)
58.5
kg
359
mm
596 x 1760 x 680
400V 3N~
ºC
110
l/s
0.40
0.40
5.9 (6 kPa)
5.9 (6 kPa)
l/s
0.81
0.81
LEP (Low Energy Pump)
Electrical data
Name
Type
Operating system
Rated power
Rated current
IP class
Max. operating current Compressors
Max. operating current Compressor
Name
Type
Operating system
Rated power
Rated current
IP class
Max. operating current Compressors
Max. operating current Compressor
Max starting current
Operational data for heat pump
Output from compressor
1)
@ -5/45
Output from compressor
1)
@ -5/45
Output from compressor
1)
@ 0/35 0/45 0/55
Output from compressor
1)
@ 0/35 0/45 0/55
Output from compressor
1)
@ 5/35 5/45 5/55
Output from compressor
1)
@ 5/35 5/45 5/55
1)
EN14511:2007, inclusive circulation pumps
Brine system
Water volume (V)
Brine system min/max temp. (TS)
Brine system min/max pressure (PS)
Brine system min fl ow ∆t = 5 K
Brine system nominal fl ow ∆t = 3 K
Kvs value ∆t = 3 K at nominal fl ow
Brine system pump
Class A circulation pump (LEP)
Pump capacity
See diagram in the Pipe installation chapter
Other data
Refrigerant quantity (R407C, fl uorinated
greenhouse gases GWP 1774)
CO
2
equivalent
Compressor oil
Pressure switch cut-off HT
Sound power EN 12102 +/-2 dB(A)
Weight net
Width x Height x Depth
Heating system
Max temperature heating medium (TS)
Heating system min fl ow
2)
Kvs value ∆t = 10 K, at min fl ow
Heating system nominal fl ow
3)
Heating medium pump
2)
∆t = 10 K och 0/35 °C heat pump operation.
3)
∆t = 5 K och 0/35 °C heat pump operation.