5.3

 

Changing purging duration 

General Comments 

Condensate purging automatically starts every 5 minutes for duration adjustable from 1 to 20 seconds.  The 
factory setting meets nominal drier operation conditions.  However, you may have to:   

 

Increase the duration of purging if the temperature of the air to be treated is higher than nominal and if 
you find liquid phase water downstream from the drier.   

 

Reduce the duration of purging if the temperature of the air to be treated is lower than nominal (case of a 
water-type final cooling agent downstream from the air compressor) or if the compressed air to be treated 
is not moisture-saturated (due to pre-drying or partial expansion)  

Correct adjustment of the duration of purging is designed to limit compressed air leakage of to the bare 
minimum necessary for this operation.  

Correctly regulated purging:   

 

expels condensates (oil/water emulsion) during most of the purging sequence.   

 

releases a short blast of dry, condensate-free, compressed air at the end of the purging sequence.  

Adjustment   

 

Press on button 

ž

 

for 15 seconds.  

The purge duration value flashes on the digital display panel.   

 

Use the buttons                      to modify the purging duration value 

The adjustment range is from 1 to 10 seconds.  

 

To record the new value, wait 5 seconds without pressing a key.  The digital display panel reverts to its 
normal status (i.e. stops flashing).  

 

 

In case of extreme conditions of air drier working, it’s possible to adjust the closing time of the solenoid valve. 
Example, for adjusting the closing time 4 minutes (value adjusted in factory) to 2 minutes: 

 

Press on button       

 

for 15 seconds.  

The purge duration value flashes on the digital display panel.   

 

Use the buttons                      to modify the closing time to 2 minutes for example 

 

To record the new value, wait 5 seconds without pressing a key.  The digital display panel reverts to its 
normal status (i.e. stops flashing). 

5.4

 

Purge test  

General comments  

Use the purging TEST button for:   

 

first start up   

 

routine testing,   

 

to depressurise the drier for maintenance.  

Procedure  

1.

 

Press the TEST button.  Check that the solenoid valve opens and those condensates run out.  Check that 
the Purge LED comes ON.  

2.

 

Press the TEST button.  Check that the solenoid valve is closed and that condensate purging stops.  

3.

 

Wait 5 minutes and re-check that purging is carried out correctly.  

4.

 

If necessary, change the purge duration (see § 5.3).  

Note:  Each pressure on the TEST button opens or closes the solenoid purge valve.  If you leave the solenoid purge valve 

open, it will be closed automatically at the end of the pre-set purge duration time.  

Summary of Contents for MASTERIA MPE 004

Page 1: ...of the Air ZA du caillou 3 rue Jules Verne 69630 CHAPONOST FRANCE Phone 33 0 4 78 56 70 70 Fax 33 0 4 78 56 17 31 Instruction Manual MASTERIA compressed air dryer INSTALLATION USE MAINTENANCE Models...

Page 2: ...ce 9 5 2 Changing set points 9 5 3 Changing purging duration 10 5 4 Purge test 10 5 5 Choice temperature unit 11 6 Maintenance preparation 11 6 1 Shut down and close all circuits 11 6 2 Access inside...

Page 3: ...due to an air to air heat exchanger in all models in the range above the MPE010 The dry cold air from the drier is used to pre cool the hot wet air inlet Mechanical separation guaranteed in all opera...

Page 4: ...s install manual valves so each machine can be isolated separately Fit a safety valve to each tank or appliance containing air at a pressure higher than atmospheric pressure Fit a safety valve between...

Page 5: ...PROGRESS DO NOT ENERGISE warning panel Do not touch the master switch and do not try to start the drier if the warning panel is in place 3 Close the by pass valves up and down stream from the drier an...

Page 6: ...ratures are specified on the manufacturer s plate on the drier Unless otherwise stated dryers are designed to function in ambient conditions at a temperature of 25C Higher temperatures may reduce the...

Page 7: ...or treatment see ISO standard 8573 1 For air dryer inlet and outlet connexion s tightening be sure not to use too much screwing tight power which would damage the evaporator coil piping of the thermal...

Page 8: ...inutes and will only start again when the digital display panel indicates 04 C or 39 F If the compressed air flow oscillates it is normal for these values to be exceeded temporarily 10 Check that the...

Page 9: ...unit s electronic regulation LEDs 4 LEDs indicate the operating condition of the drier or the regulation 5 2 Changing set points General The factory programmed set point normally meets the nominal ca...

Page 10: ...on value flashes on the digital display panel Use the buttons to modify the purging duration value The adjustment range is from 1 to 10 seconds To record the new value wait 5 seconds without pressing...

Page 11: ...liance OFF as stipulated in 4 1 Lock the power supply cut out switches OPEN Lock the upstream and downstream valves CLOSED and the by pass valve OPEN Check that the appliance is depressurised by press...

Page 12: ...variation in pressure could damage the drier 3 Slowly open the upstream valve 4 Slowly close the by pass valve 7 Maintenance operation Various risks electrocution explosion The following operations m...

Page 13: ...to the solenoid purge valve 10 Open the manual valve on the purging line You must comply with the recommendations at the beginning of this chapter 8 Test and maintenance scheduling Frequency of interv...

Page 14: ...er 9 Alarm When temperature sensor is broken or short circuited the first digit point see diagram 5 1 will blink and the display show value 00 In the same time the compressor of the drier cut off Repl...

Page 15: ...low through the drier The condensates have frozen and block the passage as the probe is incorrectly positioned Compressed air does not flow through the drier Position the probe in the centre of the DT...

Page 16: ...a high evaporation pressure of raised and higher purging from the separator Correct the temperature and the air flow to pre set limits Press the red button on the Pressure switch cap F Low pressure L...

Page 17: ...5 1 1 1 3 1 5 1 85 2 2 2 4 2 8 3 2 3 50 Refrigerant Fluid R134a R407c Load gr see on the data sticker at the back panel HP Pressure switch bar 18 26 Manual Reset LP pressure controller bar 1 automatic...

Page 18: ...the operations described in 4 3 and 4 4 must be carried out Your Mast ria drier is pre fitted for an external purge with a level detection system To connect this type of purge you must 1 Raise your d...

Page 19: ...4A Label Components 006 020 025 125 AO Compressed air exhaust AI Compressed air inlet CD Condensing unit CF Condensate filter CO Condensate discharge CP Compressor CS Condensate separator CT Capillary...

Page 20: ...ng 14 2 Wiring diagrams SE00148 SE0015 SE0018 SE0017 and SE0018 Label Components M1 Compressor M2 Fan motor EC Electronic card EV Solenoid purge valve HPS High pressure switch LPS Low pressure switch...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ......

Reviews: