SIGNATURE 2 SERIES
Installation
6
5. Install Peroxide Feed System to HYDROXR™ Tank Manifold. The white colored 1/4” MNPT injection fitting is located in
Peroxide Feed System carton. Peroxide Feed Pump and Solution Tank are pre-assembled at the factory.
Note :
Do not remove clear plastic covering injection fitting nozzle!!
A. Install injection check valve assembly (located in peroxide feed pump carton) into one of the two 1/4” FNPT openings
in base of HYDROXR Tank Manifold.
B. Connect tubing from feed pump outlet to injection check valve.
Note :
Do not connect feed pump outlet tubing to air vent hose barb!
C. Turn off power to well pump pressure switch. Install electrical receptacle on wall near Peroxide Feed Pump pressure
switch. Wire receptacle to pressure switch. (See Typical Installation Drawing.)
Warning :
Verify voltage of well pump and peroxide feed pump. Connecting feed pump to improper voltage source will
void the warranty!!
D. Turn on power to well pump pressure switch.
6. Rotate handle of the bypass position across the bypass.
7. Turn the main supply line on to restore water service to the home.
8. OPEN nearest faucet to evacuate air and repressurize plumbing lines.
9. Check for leaks!
-Drain Line Connections-
1. Pull out clip and remove drain line assembly located on back left side of control valve. Remove drain line hose barb and
wrap threads with Teflon tape. Reinstall drain line hose barb. Caution : Hand tighten only!! Replace drain line assembly
and reinstall clip.
2. Install 1/2” I.D. drain line tubing (not included) from hose barb to an open drain. A 4” air gap between the end of the
drain line and the open drain is required to prevent waste water backflow. Keep the drain line as short as possible. An
overhead drain line can be used if necessary, but should discharge below the control valve. A siphon trap (taped loop)
at the outlet of the drain line is advisable to keep the drain line full and assure correct flow during backwash. Elbows or
other fittings must be kept at a bare minimum.
3. Install included 3/8” x 1/4” tubing to air vent hose barb on HYDROXR Aeration Manifold and run to a drain. An air gap
must be provided.
Warning :
Do not tee air vent line to drain line or soil line. Protect air vent line from freezing!
Note :
Where the drain line is elevated above the control valve or exceeds 20’ in length, 3/4” I.D. drain line tubing should
be used.
Warning :
If multiple backwashing style units are used, DO NOT tee drain lines together!!!