SIGNATURE 2 SERIES
-Installation Requirements-
HYDROXR™ Tank
• A level floor position ahead of piping into water heater.
• Unit must be installed at least 10’ ahead of the inlet to a water heater to prevent damage due to
back-up of hot water.
• DO NOT install the unit in an area of direct sunlight or where freezing temperatures may occur!
Peroxide Feed System
• Leave ample room near HYDROXR™ Tank to accommodate the Peroxide Feed System.
Filter Tank
• A level floor position ahead of piping into water heater.
• Unit must be installed at least 10’ ahead of the water heater to prevent damage due to back up of hot water.
• DO NOT install unit in an area of direct sunlight or where freezing temperatures may occur!
Installation
4
Note : Caution should always be used in sizing filters! Always choose a unit by first satisfying the Backwash requirement.
Use of a flow control in the Service Line is highly recommended. Consult the factory or your field sales person with
questions.